Sistema de Reemplazo de Cadera (HRS-P) en Artroplastia Total de Cadera Primaria ((HRS-P))
Un estudio prospectivo multicéntrico del sistema de reemplazo de cadera Hip Innovation Technology (HIT) en la artroplastia total de cadera primaria
To evaluate effectiveness and safety of HHRS in subjects undergoing total hip arthroplasty (THA). Effectiveness will be evaluated using patient-reported, clinical, radiologic, and radiostereometric outcomes. Safety will be evaluated through the collection of device-related and unanticipated device-related adverse events.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
The HIT Hip Replacement System (HHRS) is a Metal-on-Polyethylene (MoP) conventional hip prosthesis. The HHRS consists of a femoral stem, an acetabular cup and a Cobalt Chromium Molybdenum (CoCrMo) ball that articulates within a polyethylene liner. The ball sits on the acetabular cup, and the polyethylene liner is attached to the femoral cup, which attaches to the femoral stem, instead of the acetabular cup. The acetabular component of the HHRS consists of a hemispherical acetabular shell with a clustered screw-hole design. The outside of the shells are coated with titanium plasma to facilitate bone in-growth and provide secure intermediate fixation with the prepared bone surface at the site of implantation. The acetabular cup has a 3-hole design that accommodates three titanium alloy bone screws. Inside the acetabular cup is a male taper for assembly with the acetabular ball. The femoral component consists of a femoral stem manufactured from titanium and a mating cobalt chrome femoral cup lined with a highly cross-linked ultra-high-molecular-weight polyethylene (UHMWPE). As with the acetabular cup, the femoral stem is porous coated using a plasma spray of pure titanium, which is intended to facilitate bone in-growth and provide secure intermediate fixation with the prepared bone surface at the site of implantation. The femoral stem incorporates a female taper for assembly with the male taper of the femoral cup.
The device has undergone extensive pre-clinical testing. There is no clinical experience with the HRS.
Tipo de estudio
Tipo de estudio
Inscripción (Estimado)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
Estudio Contacto
- Nombre: Linda Braddon, PhD
- Número de teléfono: 770-837-2681
- Correo electrónico: LGB@SecureBME.com
Copia de seguridad de contactos de estudio
- Nombre: Thomas Turgeon, MD
- Número de teléfono: 204-926-1218
- Correo electrónico: tturgeon@cjrg.ca
Ubicaciones de estudio
-
-
Manitoba
-
Winnipeg, Manitoba, Canadá, R2K 2M9
- Reclutamiento
- Orthopaedic Innovation Centre
-
Contacto:
- Thomas Turgeon, MD
- Número de teléfono: (204) 926-1218
- Correo electrónico: tturgeon@cjrg.ca
-
Contacto:
- Sarah Tran
- Número de teléfono: (204) 926-1231
- Correo electrónico: stran@orthoinno.com
-
Investigador principal:
- Thomas Turgeon, MD
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Patient has a non-inflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses such as osteoarthritis, avascular necrosis, traumatic arthritis, slipped capital epiphysis, fracture of the pelvis, and diastrophic variant requiring unilateral primary total hip replacement.
- Age between 65 and 79 years (inclusive) at the time of enrollment.
- Patient is a suitable candidate for primary total hip replacement at the discretion of the Investigator.
- Pre-surgery (within 28 days before surgery) WOMAC Global Score of 40 or larger on a scale from 0 (best) to 96 (worst)
- Signed and dated informed consent document.
- Patient is willing and able to participate in required follow-up visits at the Investigational site and to complete study procedures and questionnaires.
Exclusion Criteria:
- Patient has had total hip replacement, hemi-arthroplasty, or fusion in either hip in the last 12 months;
- Patient has planned total hip arthroplasty on a contra-lateral joint in the next 12 months;
- Patient has a known allergy to any component of the study device;
- Patient has a history of active sepsis in the joint;
- Patient has an insufficient acetabular or femoral bone stock in which good anchorage of the implants are unlikely or impossible;
- Patient has total or partial absence of the muscular or ligamentous apparatus;
- Patient has known moderate to severe renal insufficiency;
- Patient has vascular insufficiency, muscular atrophy, or neuromuscular disease in either leg (based on the Investigator's discretion);
- Patient has a deformity of the affected limb or significant anatomic variance of the affected hip;
- Patient has an active malignancy or history of invasive malignancy within the last five years, with the exception of superficial basal cell carcinoma or squamous cell carcinoma of the skin that has been definitively treated. Patients with carcinoma in situ of the uterine cervix definitively treated more than 1 year prior to enrollment may enter the study;
- Patient has any condition which may, in the opinion of the Investigator, interfere with the total hip replacement survival or patient outcomes (e.g. Paget's disease, Charcot's disease);
- Patient has rheumatoid arthritis or other autoimmune condition that affect joints (e.g. Lupus Arthritis);
- Patient has any condition that would interfere with patient self-assessment or pain, the function or quality of life required for patient reported outcomes during the study (based on the Investigator's discretion);
- Body Mass Index (BMI) of 40 or more;
- Patient has an active infection (e.g. hepatitis, AIDS, ARC) - systemic or at the site of intended surgery;
- Patient is currently participating in any investigational study not related to this study's pre-operative or post-operative care;
- Patient has any other severe acute or chronic medical condition that may interfere with the interpretation of the study results, in the judgment of the Investigator, which would make the patient inappropriate for entry into this study;
- Patient has a history of metabolic bone disease (e.g. Paget's disease or osteomalacia);
- Patient is currently pregnant or is planning to become pregnant.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: HIT Hip Replacement System (HRS)
Single group assignment with historical controls. |
HIT Hip Replacement System |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Cambio en la puntuación de limitaciones funcionales de la escala de Likert del índice de osteoartritis de las universidades de Western Ontario y McMaster (WOMAC) v3.0 entre el inicio (preoperatorio) y el punto temporal de seguimiento postoperatorio de 730 días.
Periodo de tiempo: entre preoperatorio y 730 días (24 meses)
|
entre preoperatorio y 730 días (24 meses)
|
|
Cambio en la puntuación de cadera de Harris entre el valor inicial (preoperatorio) y el punto temporal de seguimiento postoperatorio de 730 días.
Periodo de tiempo: entre preoperatorio y 730 días (24 meses)
|
entre preoperatorio y 730 días (24 meses)
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Cambio en Oxford Hip Score entre 730 días después de la operación y el valor inicial (antes de la cirugía)
Periodo de tiempo: entre 730 días después de la operación y la línea de base (antes de la cirugía)
|
entre 730 días después de la operación y la línea de base (antes de la cirugía)
|
|
Cambio en la puntuación del componente físico (PCS) de forma abreviada 36 v2 entre 730 días después de la operación y la línea de base (antes de la cirugía)
Periodo de tiempo: entre 730 días después de la operación y la línea de base (antes de la cirugía)
|
entre 730 días después de la operación y la línea de base (antes de la cirugía)
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Thomas Turgeon, MD, Orthopaedic Innovation Centre
- Director de estudio: Branko Kopjar, MD, PhD, Nor Consult, LLC
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Estimado)
Finalización primaria
Finalización del estudio (Estimado)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimado)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- HIT-001
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .