Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Estudio de monitorización óptica con espectroscopia de infrarrojo cercano para lesiones de la médula espinal

18 de septiembre de 2026 actualizado por: Brian Kwon, University of British Columbia

Ensayo "OMNI-SCI" - Ensayo "Monitoreo óptico con espectroscopia de infrarrojo cercano para lesiones de la médula espinal"

The study involves the 'first-in-human' evaluation of a novel optical sensor which uses near-infrared spectroscopy (NIRS) technology to assess oxygenation and hemodynamics of the injured spinal cord. The NIRS sensor is laid on top of the dura, at the site of the SCI, and emits near-infrared light signals into the cord to measure tissue oxygenation and tissue hemodynamics in real-time. Our testing of this novel NIRS sensor in patients with acute SCI represents the first step in translating this technology for human use.

Descripción general del estudio

Estado

Terminado

Condiciones

Intervención / Tratamiento

Descripción detallada

This single-center, prospective observational study will enroll 10 patients admitted to Vancouver General Hospital (VGH) for treatment of an acute traumatic spine injury.

Promising preclinical data demonstrates that the oxygenation and hemodynamic measures of our Near Infra-Red Spectroscopy (NIRS) system closely match the invasive intraparenchymal measures obtained within the injured spinal cord. Further, the NIRS sensor is responsive and reflective of systemic hemodynamic changes. This clinical protocol represents the first application of this novel NIRS sensor in human SCI. Following operative decompression of the spinal cord via a posterior approach, the NIRS sensor will be placed over the dura for 7 days to monitor spinal cord oxygenation and tissue hemodynamics. Patients will be followed for 6 months and data collection for safety, feasibly and efficacy of the NIRS System.

The specific aims of this project are to:

  1. Establish the safety, feasibility, and efficacy of our NIRS system in monitoring tissue oxygenation and hemodynamics of the injured spinal cord in human participants.
  2. Complete the technical refinement of the NIRS system utilizing an iterative process guided by participant recruitment and data accrual during the trial.

Tipo de estudio

Intervencionista

Inscripción (Actual)

1

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • British Columbia
      • Vancouver, British Columbia, Canadá, V5Z1M9
        • Vancouver General Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

17 años y mayores (Niño, Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Male or female aged 17 years or older
  • Spinal injury between bony levels C3 and L1 inclusive
  • Motor complete acute traumatic SCI (AIS A or B) or motor incomplete SCI (AIS C) with a total lower extremity motor score of less than 5
  • Blunt (non-penetrating) SCI requiring posterior laminectomy with stabilization/fusion surgery within 72 hours of injury
  • Able to communicate in English and provide informed consent

Exclusion Criteria:

  • Isolated radiculopathy or cauda equina injury
  • Spinal cord impairment secondary to tumour, infection, epidural bleeding, or ischemia (in
  • Any condition or injury (e.g. Morel-Lavellee lesion) that would interfere with the application or readings of the NIRS sensor
  • Associated traumatic condition that would interfere with the informed consent process or outcome assessments (e.g. traumatic brain injury, pelvic, abdominal, or thoracic injuries)
  • Any other medical condition that, in the investigator's opinion, would render the protocol procedures dangerous
  • Female patients who are pregnant

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Viabilidad del dispositivo
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Arm 1

NIRS monitoring of spinal cord oxygenation and hemodynamics

The NIRS sensor is laid on top of the dura, at the site of the SCI, and emits near-infrared light signals into the cord to measure tissue oxygenation and tissue hemodynamics in real-time.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Feasibility Assessment - Overall
Periodo de tiempo: Day 7

Study specific questionnaire will collected data on the the ease of sensor application, NIRS monitoring and sensor removal is recorded with this form. Series of questions requiring the assessment of the NIRS system using yes/no and 10-point scoring scale

Day 7
Feasibility Assessment: Sensor Application
Periodo de tiempo: Day 1

Study specific form will be used record data associated with application of the NIRS sensor, such as the laminectomy and instrumentation data, location of the sensor and ease of application (score out of 10).

Day 1
Feasibility Assessment: Sensor Removal
Periodo de tiempo: Day 7

Study specific form will be used to record the condition of the sensor and participants' experience (score out of 10) at the time of sensor removal

Day 7

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
Safety Assessment - Neurologic Function
Periodo de tiempo: 6 Month

Neurologic function will be assessed using the International Standards for Neurologic Classification of Spinal Cord Injury (ISNCSCI) to determine if the application, 7-day placement, or removal of the NIRS sensor is associated with any deterioration in spinal cord function.

6 Month
Safety Assessment - Wound Assessment
Periodo de tiempo: Day 7

The externalization of a foreign body may lead to an increased risk of surgical site infection. Any incidence of wound infection will be monitored and document on a wound assessment form.

Day 7
Safety Assessment - Adverse Events
Periodo de tiempo: 6 Months

The incidence of AEs in the acute SCI patient population is significant. For the purposes of this study, and in keeping with standard of care on the Acute Spine Unit at study site, all AEs will be recorded utilizing the Spine Adverse Event (SAVES) form, a well-established system for prospectively documenting AEs in spine patients

6 Months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Investigadores

  • Investigador principal: Brian Kwon, MD, PhD, University of British Columbia

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

24 de septiembre de 2022

Finalización primaria (Actual)

26 de octubre de 2022

Finalización del estudio (Actual)

1 de abril de 2026

Fechas de registro del estudio

Enviado por primera vez

15 de marzo de 2021

Primero enviado que cumplió con los criterios de control de calidad

19 de marzo de 2021

Publicado por primera vez (Actual)

23 de marzo de 2021

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

23 de septiembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

18 de septiembre de 2026

Última verificación

1 de junio de 2023

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • H20-01259.
  • CDMRP- SC200036 (Otro número de subvención/financiamiento: CDMRP)

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .