Monitoraggio ottico con spettroscopia nel vicino infrarosso per la prova delle lesioni del midollo spinale
Prova "OMNI-SCI" - Prova "Monitoraggio ottico con spettroscopia nel vicino infrarosso per lesioni del midollo spinale"
The study involves the 'first-in-human' evaluation of a novel optical sensor which uses near-infrared spectroscopy (NIRS) technology to assess oxygenation and hemodynamics of the injured spinal cord. The NIRS sensor is laid on top of the dura, at the site of the SCI, and emits near-infrared light signals into the cord to measure tissue oxygenation and tissue hemodynamics in real-time. Our testing of this novel NIRS sensor in patients with acute SCI represents the first step in translating this technology for human use.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
This single-center, prospective observational study will enroll 10 patients admitted to Vancouver General Hospital (VGH) for treatment of an acute traumatic spine injury.
Promising preclinical data demonstrates that the oxygenation and hemodynamic measures of our Near Infra-Red Spectroscopy (NIRS) system closely match the invasive intraparenchymal measures obtained within the injured spinal cord. Further, the NIRS sensor is responsive and reflective of systemic hemodynamic changes. This clinical protocol represents the first application of this novel NIRS sensor in human SCI. Following operative decompression of the spinal cord via a posterior approach, the NIRS sensor will be placed over the dura for 7 days to monitor spinal cord oxygenation and tissue hemodynamics. Patients will be followed for 6 months and data collection for safety, feasibly and efficacy of the NIRS System.
The specific aims of this project are to:
- Establish the safety, feasibility, and efficacy of our NIRS system in monitoring tissue oxygenation and hemodynamics of the injured spinal cord in human participants.
- Complete the technical refinement of the NIRS system utilizing an iterative process guided by participant recruitment and data accrual during the trial.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
British Columbia
-
Vancouver, British Columbia, Canada, V5Z1M9
- Vancouver General Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Male or female aged 17 years or older
- Spinal injury between bony levels C3 and L1 inclusive
- Motor complete acute traumatic SCI (AIS A or B) or motor incomplete SCI (AIS C) with a total lower extremity motor score of less than 5
- Blunt (non-penetrating) SCI requiring posterior laminectomy with stabilization/fusion surgery within 72 hours of injury
- Able to communicate in English and provide informed consent
Exclusion Criteria:
- Isolated radiculopathy or cauda equina injury
- Spinal cord impairment secondary to tumour, infection, epidural bleeding, or ischemia (in
- Any condition or injury (e.g. Morel-Lavellee lesion) that would interfere with the application or readings of the NIRS sensor
- Associated traumatic condition that would interfere with the informed consent process or outcome assessments (e.g. traumatic brain injury, pelvic, abdominal, or thoracic injuries)
- Any other medical condition that, in the investigator's opinion, would render the protocol procedures dangerous
- Female patients who are pregnant
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Fattibilità del dispositivo
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Arm 1
NIRS monitoring of spinal cord oxygenation and hemodynamics |
The NIRS sensor is laid on top of the dura, at the site of the SCI, and emits near-infrared light signals into the cord to measure tissue oxygenation and tissue hemodynamics in real-time. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Feasibility Assessment - Overall
Lasso di tempo: Day 7
|
Study specific questionnaire will collected data on the the ease of sensor application, NIRS monitoring and sensor removal is recorded with this form. Series of questions requiring the assessment of the NIRS system using yes/no and 10-point scoring scale |
Day 7
|
|
Feasibility Assessment: Sensor Application
Lasso di tempo: Day 1
|
Study specific form will be used record data associated with application of the NIRS sensor, such as the laminectomy and instrumentation data, location of the sensor and ease of application (score out of 10). |
Day 1
|
|
Feasibility Assessment: Sensor Removal
Lasso di tempo: Day 7
|
Study specific form will be used to record the condition of the sensor and participants' experience (score out of 10) at the time of sensor removal |
Day 7
|
Altre misure di risultato
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Safety Assessment - Neurologic Function
Lasso di tempo: 6 Month
|
Neurologic function will be assessed using the International Standards for Neurologic Classification of Spinal Cord Injury (ISNCSCI) to determine if the application, 7-day placement, or removal of the NIRS sensor is associated with any deterioration in spinal cord function. |
6 Month
|
|
Safety Assessment - Wound Assessment
Lasso di tempo: Day 7
|
The externalization of a foreign body may lead to an increased risk of surgical site infection. Any incidence of wound infection will be monitored and document on a wound assessment form. |
Day 7
|
|
Safety Assessment - Adverse Events
Lasso di tempo: 6 Months
|
The incidence of AEs in the acute SCI patient population is significant. For the purposes of this study, and in keeping with standard of care on the Acute Spine Unit at study site, all AEs will be recorded utilizing the Spine Adverse Event (SAVES) form, a well-established system for prospectively documenting AEs in spine patients |
6 Months
|
Collaboratori e investigatori
Sponsor
Sponsor
Collaboratori
Collaboratori
Investigatori
Investigatori
- Investigatore principale: Brian Kwon, MD, PhD, University of British Columbia
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
- Malattie del sistema nervoso centrale
- Malattie del sistema nervoso
- Ferite e lesioni
- Trauma, sistema nervoso
- Malattie del midollo spinale
- Lesioni del midollo spinale
- Tecniche investigative
- Tecniche e procedure diagnostiche
- Diagnosi
- Imaging diagnostico
- Tecniche di chimica, analitiche
- Analisi dello spettro
- Spettroscopia, vicino infrarosso
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- H20-01259.
- CDMRP- SC200036 (Altro numero di sovvenzione/finanziamento: CDMRP)
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .