MindEx: un sistema de interfaz cerebro-máquina novedoso, multifocal y cognitivo
This research study is being done to develop a novel brain-computer interface (BCI) technology that can enable severely paralyzed individuals to interact with the world through direct brain-control of a computer. This technology is named MindEx (for Mind Extender). It utilizes four implanted "chips" in the human brain from which investigators can record brain activity during subjects' thoughts and decode meaningful information from this activity to be used as control signals for a computer, a laptop, or a tablet. The use of four brain regions is a significant differentiating feature and scientific innovation of this study over much prior work in this space, that typically derived control signals from one, or sometimes two brain regions. The brain regions to be used here can allow the decode of multiple variables simultaneously, including not just moment-to-moment position, but also high-level goals, intentions, decisions, scene comprehension, and error-related signals involved in natural human behavior. The research is being done through a prospective, longitudinal, single-arm early feasibility study to examine the safety and effectiveness of using MindEx to provide the user an intuitive, efficient, and accurate ability to control multiple applications on a computer interface such as a word processor, a paint application, or to play simple video games. Such versatility could greatly improve the autonomy and quality of life of severely paralyzed individuals. Two subjects will be enrolled, each implanted with MindEx for a period of at least 53 weeks and up to 313 weeks. The study is expected to take at least one year and up to six years in total.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
- Parálisis
- Esclerosis lateral amiotrófica (ELA)
- Lesión de la médula espinal cervical
- Tetraplejia
- Interfaz cerebro-computadora
- Cuadraplejia
- Accidente cerebrovascular del tronco encefálico
- Parálisis; tetrapléjico
- Disfunción motora tetrapléjica tras lesión del tronco encefálico o de la médula espinal
- BCI
Intervención / Tratamiento
Intervención / Tratamiento
Tipo de estudio
Tipo de estudio
Inscripción (Estimado)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
Estudio Contacto
- Nombre: Nader Pouratian, MD, PhD
- Número de teléfono: 214-645-5465
- Correo electrónico: nader.pouratian@utsouthwestern.edu
Copia de seguridad de contactos de estudio
- Nombre: Olivia Gibble, MS
- Número de teléfono: 214-648-8880
- Correo electrónico: Olivia.gibble@utsouthwestern.edu
Ubicaciones de estudio
-
-
Texas
-
Dallas, Texas, Estados Unidos, 75390
- Reclutamiento
- UT Southwestern Medical Center
-
Contacto:
- Cecile Verbaarschot, MD, PhD
- Número de teléfono: 2146483395
- Correo electrónico: Cecile.Verbaarschot@UTSouthwestern.edu
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Paralysis resulting from cervical spinal cord injury (SCI), brainstem stroke (ischemic or hemorrhagic), or amyotrophic lateral sclerosis (ALS)
- Provide informed consent
- Understand and comply with instructions, if necessary, with the aid of a translator
- Communicate via speech or other means
- Surgical clearance
- Life expectancy greater than 12 months
- Travel to study locations up to five days per week for the duration of the study
- Caregiver monitor for surgical site complications and behavioral changes on a daily basis
- Psychosocial support system
- Stable ventilator status
Exclusion Criteria:
- Presence of memory problems
- Intellectual impairment
- Psychotic illness or chronic psychiatric disorder, including major depression if untreated
- Poor visual acuity
- Pregnancy
- Active infection or unexplained fever
- Scalp lesions or skin breakdown
- HIV or AIDS infection
- Active cancer or chemotherapy
- Diabetes
- Autonomic dysreflexia
- History of seizure
- Implanted hydrocephalus shunt
- Prior cranioplasty
- Other implanted devices
- Medical conditions contraindicating surgery and chronic implantation of a medical device
- Unable to undergo MRI or anticipated need for MRI during the study
- Breastfeeding an infant (direct nursing or via a bottle of expressed milk)
- Chronic oral or intravenous use of steroids or immunosuppressive therapy
- Suicidal ideation
- Drug or alcohol dependence
- Planning to become pregnant, or unwilling to use adequate birth control
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Viabilidad del dispositivo
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: Mind Extender (MindEx)
MindEx consists of two Neuroport Multi-Port Arrays, described in detail in the intervention description. Each NeuroPort Multi-Port Array comprises two electrode arrays implanted into human brain tissue, for a total of four electrode arrays. These will be in 1) prefrontal cortex, a brain area involved in scene comprehension, action selection, and error signaling, 2) premotor cortex, a brain area involved in planning ongoing and upcoming actions, 3) posterior parietal cortex, a brain area involved in processing sensory-to-motor transformations during movements, and 4) primary motor cortex, responsible for controlling movement. The pair of electrode arrays in each NeuroPort Multi-Port Array connect to a single percutaneous pedestal attached to the skull during a surgical procedure. Following recovery from the surgical placement, subjects will participate in study sessions up to 5 times a week. They will learn to use thought to control applications on a computer, a laptop, or a tablet. |
NeuroPort Multi-Port Arrays allow for the local recording of cerebral cortex. The Mind Extender (MindEx) system is primarily composed of two NeuroPort Multi-Port Arrays. Each Multi-Port device consists of two arrays, each with 100 electrodes in a 10 x 10 configuration, with dimensions 4 mm x 4 mm x 1.5 mm (W x H x D), and a titanium percutaneous connector, 19 mm diameter at the base. Each MultiPort can have a total of 128 active channels (capable of transmitting neural signals to the percutaneous connector) across the two arrays. In our design, we will split active channels evenly between the two arrays resulting in 64 active channels per array. The four arrays of the two Multi-Port device will be implanted into prefrontal cortex, premotor cortex, primary motor cortex, and posterior parietal cortex. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Continuous trajectory decoding
Periodo de tiempo: Six years after array implantation
|
A primary objective of this study is to evaluate the effectiveness of the system in providing users the ability to continuously move a cursor on a tablet/computer. The hypothesis is that trajectory readability from neural signals will be significantly greater than the level of chance. Standardized tests will be used to test this objective, and performance will be compared to the level of chance. One example of a standardized test to be used is the accuracy of continuous trajectory decoding measured by the radial-8 assessment task. |
Six years after array implantation
|
|
Incidence of intervention-related adverse events
Periodo de tiempo: Six years after array implantation
|
Serious adverse events (SAE) will be evaluated against a 1% threshold level. We will use regular inspection of the subjects' scalps to assess for breakdown, discharge, or infection, and use history and physical exam to evaluate for new symptoms, and compare to baseline assessments. |
Six years after array implantation
|
|
Competency in computer/tablet control
Periodo de tiempo: Six years after array implantation
|
An underlying hypothesis in this study is that the system will enable users the ability to control a computer/tablet interface by selecting icons. An underlying hypothesis in the study is that neural signals will enable decoding the chosen target at higher accuracy than the level of chance. Standardized tests will be used to test this objective, and performance will be compared to the level of chance. An example of a standardized test to be used is the brain-control for tablet test (BCTT) which grades the accuracy of target selection by mental fixation to the level of chance. |
Six years after array implantation
|
|
Efficacy of multiple brain regions for neural control over subsets of brain regions
Periodo de tiempo: Six years after array implantation
|
An objective of this study is to determine whether the combination of neural signals from multiple brain regions in brain-computer interface control is more advantageous than from a subset of the brain regions being tested. The hypothesis is that because the four brain regions being implanted each encode different cognitive functions, their integration will be more useful to brain-computer interface control, than any subset of these regions. This objective will be tested by standardized tests (such as those mentioned for "Competency in computer/tablet control" and "Continuous trajectory decoding") in different groups of brain regions and reported for each, such as:
|
Six years after array implantation
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Change in quality of life
Periodo de tiempo: Time Frame: Annually, for six years
|
The functional change in quality of life will be evaluated through a Quality-of-Life Inventory (QOLI) administered periodically throughout the study. This is a 32-item questionnaire with a score range from 1-77, with higher scores reflecting higher satisfaction. |
Time Frame: Annually, for six years
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Estimado)
Finalización primaria
Finalización del estudio (Estimado)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
- Manifestaciones neurológicas
- Trastornos cerebrovasculares
- Enfermedades Cerebrales
- Enfermedades del Sistema Nervioso Central
- Enfermedades del Sistema Nervioso
- Enfermedades Vasculares
- Enfermedades cardiovasculares
- Heridas y Lesiones
- Procesos Patológicos
- Enfermedades Neuromusculares
- Enfermedades metabólicas
- Infarto cerebral
- Isquemia cerebral
- Infarto
- Necrosis
- Enfermedades neurodegenerativas
- Trauma, Sistema Nervioso
- Enfermedades de la médula espinal
- Proteinopatías TDP-43
- Deficiencias de proteostasis
- Isquemia
- Enfermedad de la neuronas motoras
- Carrera
- Condiciones Patológicas, Signos y Síntomas
- Enfermedades Nutricionales y Metabólicas
- Signos y síntomas
- La esclerosis lateral amiotrófica
- Lesiones de la médula espinal
- Parálisis
- Cuadriplejia
- Infartos del tronco cerebral
Otros números de identificación del estudio
Otros números de identificación del estudio
- STU-2023-0306
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
Investigators with established research programs will be eligible for data sharing. Interested investigators will be required to submit a summary of the proposed work and requested data elements. If approved by the Principal Investigator of the study, data will be shared. This data will be de-identified and coded. There is no plan to share identifiers outside the study team.
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .