Implementación en la vida real de un diagnóstico óptico basado en IA (AI-OD)
Implementación en la vida real de una estrategia de diagnóstico óptico basada en inteligencia artificial para pólipos colorrectales diminutos
This is a prospective study that is the first to implement resect and discard and diagnose and leave strategies in real-time practice using stringent documentation and adjudication by 2 expert endoscopists as the gold standard.
The primary aim of this study is to show the accuracy of intracolonoscopy AI-assisted optical diagnosis (CADx; autonomous or with human input) when the AI-assisted optical diagnosis made by the expert endoscopists is used as the reference standard. The specific aims are:
- To evaluate the accuracy of intracolonoscopy AI-assisted optical polyp diagnosis (autonomous or with human input) by comparing it to the obtained optical histology diagnoses provided by two independent expert endoscopists as the reference standard.
- To evaluate the agreement between the intracolonoscopy AI-assisted optical polyp diagnosis (autonomous or with human input) and the AI-assisted optical diagnosis performed by two independent expert endoscopists.
- To determine whether AI-assisted optical polyp diagnosis for diminutive (1-5 mm) polyps can be implemented in routine clinical practice by demonstrating that at least 70% of the approached patients are interested in undergoing AI-assisted optical diagnosis (autonomous or with human input).
- To evaluate the cost savings resulting from replacing pathology with AI-assisted optical diagnosis.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
All patients who meet the inclusion criteria can be enrolled. Eligible patients will be informed about the study through a consent form that includes information on optical diagnosis (resect and discard, diagnose and leave) and AI/CADx systems. We will ask the patients' willingness to undergo AI-assisted optical diagnosis with endoscopists' input (the first 102 patients) and automomous AI-assisted optical diagnosis (from patient 103 to 204). Subsequently, patients will be asked if they are willing to participate in the study, using AI-assisted optical diagnosis and the "resect and discard" and "diagnose and leave" strategy. If a patient declines to undergo optical diagnosis, they will be asked about the reason for their refusal to participate in the study. The options for their response include:
- Concerns regarding undergoing an optical diagnosis.
- Reluctance to participate in research projects in general.
- Other reasons.
- Preference not to answer the question.
Patients who agree to participate in the study will undergo standard colonoscopy procedures with AI-assisted optical diagnosis for all diminutive colorectal polyps identified. High-definition colonoscopes with a joint computer-assisted classification (CADx) support (CAD-EYE software EW10-EC02) will be used.
For the first 102 patients (i.e., the CAD-assisted optical diagnosis with endoscopist's input), the endoscopists will use the CAD-EYE blue light imaging (BLI) mode to enhance the visualization of polyp features. During the optical diagnosis using CADx, the most probable diagnosis (neoplastic or hyperplastic) will be displayed on the endoscopy screen. If the serrated pathology subtype is determined as the most probable histology, the endoscopists will make the final decision. They will also indicate whether their optical diagnosis was made with low or high confidence.
For the second group of 102 patients (i.e., autonomous CADx-assisted optical diagnosis), endoscopists will use CADx and BLI mode to perform optical diagnosis. Based on the CADx diagnosis, all 1-5 mm polyps diagnosed as hyperplastic or neoplastic will be resected and discarded, while those located in the rectosigmoid and diagnosed as hyperplastic will be left in the colon. When high-risk histology features are observed using BLI, in any patient, the endoscopists will inform the research assistant to document them, and the polyp will be sent for pathology examination in accordance with the ASGE PIVI guidelines recommendations. All polyps >5mm will be send for pathology evaluation. Polyp size will be measured using virtual scale technology integrated in the computer-assisted system (CAD) to ensure an accurate polyp sizing.18 A research assistant will document the characteristics of the detected polyps (i.e., location, size, morphology, AI-assisted intracolonoscopy and endoscopists optical diagnoses). All identified colorectal polyps will be removed following standard polypectomy practices. The entire colonoscopy procedures will be video recorded for quality assurance purposes. All diminutive polyps will be resected and discarded as part of the resect and discard strategy. Additionally, diminutive polyps located in the rectosigmoid colon will be detected and left in situ (diagnose and leave strategy) if no high-risk features are present.
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Quebec
-
Montreal, Quebec, Canadá
- Centre Hospitalier de l'Université de Montréal
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Age 45-80 years
- Undergoing an outpatient colonoscopy at the Centre Hospitalier de l'Université de Montréal (CHUM)
- Signed informed consent form
Exclusion Criteria:
- Inflammatory Bowel Disease;
- Active colitis;
- Hereditary CRC syndrome;
- Coagulopathy;
- American Society of Anesthesiologists (ASA) status >3
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: No aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Otro: AI-assisted classification with endoscopist's input
AI-assisted classification for diminutive polyps during a colonoscopy procedure using the CAD-eye detection and classification system, with input from the endoscopist in the case of serrated polyps, for patients who agree to undergo optical diagnosis of diminutive colorectal polyps. |
CADeye (Fujifilm, Japan) is a joint detection (CADe) and classification (CADx) AI-supported system, which has been developed utilising AI deep learning technology to support endoscopic lesion detection and characterisation in the colon.
Otros nombres:
|
|
Otro: Autonomous AI-assisted classification
AI-assisted classification for diminutive polyps during a colonoscopy procedure using the CAD-eye detection and classification system, with no input from the endoscopist, for patients who agree to undergo optical diagnosis of diminutive colorectal polyps. |
CADeye (Fujifilm, Japan) is a joint detection (CADe) and classification (CADx) AI-supported system, which has been developed utilising AI deep learning technology to support endoscopic lesion detection and characterisation in the colon.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Accuracy of the intracolonoscopy AI-assisted optical diagnosis
Periodo de tiempo: 120 days
|
Using the optical diagnosis obtained from 2 experts as the reference, the accuracy of the intracolonoscopy AI-assisted optical diagnosis (OD, with endoscopist input or autonomous) is measured as the number of correct ODs out of all ODs (%). |
120 days
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Proportion of patients who accept study participation
Periodo de tiempo: 120 days
|
Number of patients who accept to participate out of all patients approached |
120 days
|
|
Proportion of the patients unwilling to participate due to concerns regarding undergoing an optical diagnosis
Periodo de tiempo: 120 days
|
The proportion of the patients unwilling to participate in the study due to the concerns of resect and discard or diagnose and leave strategies (with endoscopist input or autonomous) and preference upon histopathological evaluation of all detected polyps |
120 days
|
|
Agreement between the intracolonoscopy AI-assisted optical diagnosis and the AI-assisted optical diagnosis by experts
Periodo de tiempo: 120 days
|
The agreement between AI-assisted OD (with and without endoscopist's input) and the experts' OD is measured as the number of cases where both ODs are the same out of all cases (%). |
120 days
|
|
Diagnostic characteristics of AI-assisted optical diagnosis using adjudication by two expert endoscopists as the reference standard
Periodo de tiempo: 120 days
|
To calculate the accuracy, sensitivity, specificity, positive predictive value, negative predictive value of (CADx) assisted optical diagnosis (resect and discard) strategy using adjudication by two expert endoscopists as the reference standard. |
120 days
|
|
Proportion of polyps with a low-confidence diagnosis
Periodo de tiempo: 120 days
|
Proportion of polyps with a low-confidence diagnosis intracolonoscopy and later by the expert independent reviewers |
120 days
|
|
Assessing cost savings through AI-assisted optical diagnosis
Periodo de tiempo: 120 days
|
The reduction in costs of the supplies and the pathology assessments according to the expenses reported by the CHUM gastroenterology and pathology departments including the expenses related to the supplies (e.g., snares, containers), immediate and delayed complications, specimen processing and equipment and physician fees. |
120 days
|
Colaboradores e Investigadores
Investigadores
- Investigador principal: Daniel von Renteln, MD, Centre hospitalier de l'Université de Montréal (CHUM)
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- 2024-11557/23.095
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .