- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07510503
The Use of Two Different Smartphone Applications in Measuring
An Investigation of the Intra- and Inter-Rater Reliability of Two Different Smartphone Applications Used in the Measurement of Sagittal Spinal Curvature
This study will include healthy volunteers aged 18-25 years. Demographic information will be recorded, and an experienced physiotherapist will mark five reference points on the spine of the participants, starting from the cervical spine and extending to the lumbar spine. Angle measurements will then be taken from these five reference points using a gravity inclinometer, an Android smartphone, and an iOS phone. Measurements will be repeated twice on the same day and twice again 24-48 hours later using three different devices. The accuracy and similarity of the measurements taken with these three devices will then be compared.
Descripción general del estudio
Estado
Condiciones
Descripción detallada
This study is designed as an observational, methodological study to investigate the intra-rater and inter-rater reliability and concurrent validity of two smartphone-based inclinometer applications used for sagittal spinal curvature assessment.
The study will include healthy volunteers aged 18-25 years. Participants will be informed about the study procedures, and written informed consent will be obtained before enrollment. Demographic and anthropometric characteristics, including age, sex, height, body weight, and body mass index, will be recorded.
Measurement Procedures An experienced physiotherapist will identify and mark five anatomical reference points along the spine, extending from the cervical region to the lumbosacral region. These reference points will be used to standardize the measurement locations across devices and assessment sessions.
Sagittal spinal inclination angles will be measured using three different devices:
A conventional gravity-based bubble inclinometer. An Android smartphone equipped with an inclinometer application. An iOS smartphone equipped with an inclinometer application. Measurements will be performed at the same anatomical reference points using all three devices. The conventional inclinometer will serve as a reference instrument for evaluating the concurrent validity of the smartphone applications.
Reliability Assessment To evaluate intra-rater and inter-rater reliability, measurements will be performed by three assessors using a standardized assessment protocol.
Each measurement will be repeated twice during the initial assessment session. A second assessment session will be conducted 24-48 hours after the first session, during which the measurements will be repeated using the same three devices.
The repeated measurements will allow the evaluation of within-assessor consistency, agreement between different assessors, and measurement stability across assessment sessions.
Concurrent Validity Assessment The measurements obtained from the Android and iOS smartphone applications will be compared with those obtained using the conventional bubble inclinometer.
The agreement between the smartphone applications and the conventional inclinometer will be examined to determine whether smartphone-based measurements provide comparable results for sagittal spinal inclination assessment.
Statistical Analysis Descriptive statistics will be used to summarize participant characteristics and measurement results.
Intraclass correlation coefficients (ICCs) will be calculated to evaluate intra-rater reliability, inter-rater reliability, and test-retest reliability. Measurement error will be examined using the standard error of measurement (SEM) and minimal detectable change (MDC).
Concurrent validity will be assessed through correlation and agreement analyses. Pearson correlation coefficients, Lin's concordance correlation coefficients, and Bland-Altman analyses will be used to investigate the relationships, concordance, and systematic differences between measurements obtained using the smartphone applications and the conventional inclinometer.
Expected Contribution The study aims to provide evidence regarding the reliability and concurrent validity of smartphone-based inclinometer applications for assessing sagittal spinal inclination. The findings may help determine the potential clinical applicability of smartphone-based measurement tools in physiotherapy and rehabilitation assessments.
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Kırşehir, Turquía (Türkiye), 40100
- Kırşehir Ahi Evran Üniversitesi
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
healthy older individuals
Descripción
Inclusion Criteria:
- Being over 18 years of age,
- being able to stand and walk without an assistive device,
- not having experienced back pain or lower extremity pain in the last 6 months,
- and being willing to participate in the study.
Exclusion Criteria:
- Lack of consent,
- lower extremity injuries (dislocation, sprain) within one month prior to measurement,
- lower extremity fractures within the last 6 months,
- tactile sensitivity that prevents the adoption of a free and habitual posture.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: COHORT
- Perspectivas temporales: CROSS_SECTIONAL
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Assessment of Spinal Curvature
Periodo de tiempo: Two measurements taken 10 minutes apart.
|
Description: The following 5 parameters were used for the measurement: 1. ALPHA 1 angle of sacrum (upper beam of the inclinometer, in the middle of the intervertebral space, on the line connecting the posterior superior iliac crests). 2. ALPHA 2 angle - sacrolumbar junction S/L (center of the inclinometer on the line connecting the posterior superior iliac crests). 3. BETA angle - Th12-L1 thoracolumbar junction (center of the inclinometer at the thoracolumbar junction). 4. GAMMA angle - C7-Th1 (center of the inclinometer on C7). 5. DELTA angle - Th3-Th4 (upper beam of the inclinometer at the height of the upper angle of the scapula). |
Two measurements taken 10 minutes apart.
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Esra BAYRAMOĞLU DEMİRDÖĞEN, Kırşehir Eğitim ve Araştırma Hastanesi
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- KAEU-EBAYRAMOGLUD-006
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .