All patients were from the surgical implantation of the ventricular catheter, arriving to the ICU intubated orally and manually ventilated with an Ambu bag. Were subjected to routine procedures: adjusting the mechanical ventilator (Inter5, Intermed, BR) during assisted controlled cycled pressure and facility to monitor vital signs. After thirty minutes of stable ICU patient in a supine position with head elevated 30 °, the protocol was initiated to assess the impact of PEEP on ICP. To perform the evaluation of lung mechanics ventilatory mode was changed to control volume with the following parameters: tidal volume (Vt) = 8ml/kg weight, peak flow (PF) = 6 x minute volume, fraction of inspired O2 (FiO2) = 40%, respiratory rate (RR) = 16 bpm, sensitivity = 1 cmH2O. The following variables were monitored: PIC, Blood Pressure (BP), heart rate (HR), peak pressure in the airways (pp.) and plateau pressure of the respiratory system (Ppl.), these values were monitored with PEEP = 5 cmH2O.
During the assessment protocol was changed to pressure control ventilation mode with the following values of ventilatory parameters: Pp = 30 cm H2O, inspiratory time = 1s; FiO2 = 40%, RR = 16 bpm; Sensitivity = 1 cmH2O. PEEP employed ranged from 0 to 14 cmH2O. To eliminate a possible physiological accommodation by the progressive increase of PEEP, the range of values was determined by drawing a sealed envelope for each patient, ranging from 2 to 2 cmH2O. At each value of PEEP the patient was ventilated for a period of five minutes to carry out monitoring of ICP, BP, HR, PPC and peripheral oxygen saturation (SpO2). The ICP monitoring catheter was kept closed for drainage and open for monitoring, since the arrival of the surgical block, was only open for drainage if there was an increase in ICP above 20 mmHg.
The monitoring was carried out using the multiparameter monitor (Siemens 7000). For ICP monitoring the ventricular catheter was connected to a pressure transducer and this monitor.
After the parameters evaluated with seven different PEEP values, the ventilatory mode was changed again to control volume again to evaluate pulmonary mechanics with the same initial parameters.
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Todellinen)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Pernambuco
-
Recife, Pernambuco, Brasilia
- Hospital Português
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- adult patients with acute CVA
- presence of ventricular drainage catheter for invasive monitoring of ICP
- without intracranial hypertension.
Exclusion Criteria:
- intracranial hypertension
- hemodynamic instability.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Crossover-tehtävä
- Naamiointi: Kaksinkertainen
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
|---|---|
|
Measurement of intracranial pressure
|
The ICP monitoring catheter was kept closed for drainage and open for monitoring, since the arrival of the surgical block, was only open for drainage if there was an increase in ICP above 20 mmHg.
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
|---|---|
|
Effect of different values of PEEP on lung mechanics
|
- Lung compliance:During the assessment protocol was changed to pressure control ventilation mode with the following values of ventilatory parameters: Pp = 30 cm H2O, inspiratory time = 1s; FiO2 = 40%, RR = 16 bpm; Sensitivity = 1 cmH2O.
PEEP employed ranged from 0 to 14 cmH2O.
|
|
Effect of different PEEP levels on aspects hemodynamic
|
At each value of PEEP the patient was ventilated for a period of five minutes to carry out monitoring of heart rate and cerebral perfusion pressure(CPP).
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Tutkijat
Tutkijat
- Opintojen puheenjohtaja: Roberto Campelo, Universidade Federal de Pernambuco
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Pillai S, Praharaj SS, Rao GS, Kolluri VR. Cerebral perfusion pressure management of severe diffuse head injury: effect on brain compliance and intracranial pressure. Neurol India. 2004 Mar;52(1):67-71.
- Mayer SA, Copeland D, Bernardini GL, Boden-Albala B, Lennihan L, Kossoff S, Sacco RL. Cost and outcome of mechanical ventilation for life-threatening stroke. Stroke. 2000 Oct;31(10):2346-53. doi: 10.1161/01.str.31.10.2346.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Ensisijainen valmistuminen
Opintojen valmistuminen (Todellinen)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Arvio)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- Berg 01
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .