Positive and Expiratory Pressure and Hemorrhagic Stroke
Effect of Positive End Expiratory Pressure on Cerebral Perfusion Pressure in Adult Patients With Hemorrhagic Stroke
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
All patients were from the surgical implantation of the ventricular catheter, arriving to the ICU intubated orally and manually ventilated with an Ambu bag. Were subjected to routine procedures: adjusting the mechanical ventilator (Inter5, Intermed, BR) during assisted controlled cycled pressure and facility to monitor vital signs. After thirty minutes of stable ICU patient in a supine position with head elevated 30 °, the protocol was initiated to assess the impact of PEEP on ICP. To perform the evaluation of lung mechanics ventilatory mode was changed to control volume with the following parameters: tidal volume (Vt) = 8ml/kg weight, peak flow (PF) = 6 x minute volume, fraction of inspired O2 (FiO2) = 40%, respiratory rate (RR) = 16 bpm, sensitivity = 1 cmH2O. The following variables were monitored: PIC, Blood Pressure (BP), heart rate (HR), peak pressure in the airways (pp.) and plateau pressure of the respiratory system (Ppl.), these values were monitored with PEEP = 5 cmH2O.
During the assessment protocol was changed to pressure control ventilation mode with the following values of ventilatory parameters: Pp = 30 cm H2O, inspiratory time = 1s; FiO2 = 40%, RR = 16 bpm; Sensitivity = 1 cmH2O. PEEP employed ranged from 0 to 14 cmH2O. To eliminate a possible physiological accommodation by the progressive increase of PEEP, the range of values was determined by drawing a sealed envelope for each patient, ranging from 2 to 2 cmH2O. At each value of PEEP the patient was ventilated for a period of five minutes to carry out monitoring of ICP, BP, HR, PPC and peripheral oxygen saturation (SpO2). The ICP monitoring catheter was kept closed for drainage and open for monitoring, since the arrival of the surgical block, was only open for drainage if there was an increase in ICP above 20 mmHg.
The monitoring was carried out using the multiparameter monitor (Siemens 7000). For ICP monitoring the ventricular catheter was connected to a pressure transducer and this monitor.
After the parameters evaluated with seven different PEEP values, the ventilatory mode was changed again to control volume again to evaluate pulmonary mechanics with the same initial parameters.
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Pernambuco
-
Recife, Pernambuco, Brasil
- Hospital Português
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- adult patients with acute CVA
- presence of ventricular drainage catheter for invasive monitoring of ICP
- without intracranial hypertension.
Exclusion Criteria:
- intracranial hypertension
- hemodynamic instability.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Dobro
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
|---|---|
|
Measurement of intracranial pressure
|
The ICP monitoring catheter was kept closed for drainage and open for monitoring, since the arrival of the surgical block, was only open for drainage if there was an increase in ICP above 20 mmHg.
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
|---|---|
|
Effect of different values of PEEP on lung mechanics
|
- Lung compliance:During the assessment protocol was changed to pressure control ventilation mode with the following values of ventilatory parameters: Pp = 30 cm H2O, inspiratory time = 1s; FiO2 = 40%, RR = 16 bpm; Sensitivity = 1 cmH2O.
PEEP employed ranged from 0 to 14 cmH2O.
|
|
Effect of different PEEP levels on aspects hemodynamic
|
At each value of PEEP the patient was ventilated for a period of five minutes to carry out monitoring of heart rate and cerebral perfusion pressure(CPP).
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Cadeira de estudo: Roberto Campelo, Universidade Federal de Pernambuco
Publicações e links úteis
Publicações Gerais
- Pillai S, Praharaj SS, Rao GS, Kolluri VR. Cerebral perfusion pressure management of severe diffuse head injury: effect on brain compliance and intracranial pressure. Neurol India. 2004 Mar;52(1):67-71.
- Mayer SA, Copeland D, Bernardini GL, Boden-Albala B, Lennihan L, Kossoff S, Sacco RL. Cost and outcome of mechanical ventilation for life-threatening stroke. Stroke. 2000 Oct;31(10):2346-53. doi: 10.1161/01.str.31.10.2346.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- Berg 01
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .