Keuhkojen toiminta ei-invasiivista pakkooskillometriaa käyttäen (PUFFOR)
Keuhkojen toiminta ei-invasiivisen pakkooskillometrisen hengitystestin avulla: tuleva havaintotutkimus
The purpose of this observational study is to measure pulmonary function in term and preterm infants with and without pulmonary disease including respiratory distress syndrome, bronchopulmonary dysplasia, transient tachypnea of the newborn, meconium aspiration syndrome, and response to treatments given to newborn infants with lung diseases using a non-invasive airway oscillometry system.
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Yksityiskohtainen kuvaus
TremoFlo™ N-100 (For Investigational Use Only) Airwave Oscillometry System™ (THORASYS Thoracic Medical Systems Inc. Montreal, Quebec, Canada) is a technology for measuring lung mechanics without patient effort. Pulmonary function testing using flow-volume and lung volumes is one of the most widely used tests to objectively measure lung function in adults. Such measurements are dependent on effort and coordination by the patient which is not possible for newborn infants. The minimum age for spirometry is typically 6 years to master the technique. Therefore, newborn infants usually require forced exhalation, flow interruption, and often sedation/anesthesia in order to obtain accurate pulmonary function measurements. Infant pulmonary function testing can be time-consuming and expensive to perform in newborn infants. This has limited the utilization of this potentially informative method of studying lung function. Measurements of lung function will be particularly informative during transition from having lungs filled with fluid during intra-uterine life to having lungs filled with air in extra-uterine life in preterm and term babies without lung disease, as well as in newborn infants with lung diseases including respiratory distress syndrome, bronchopulmonary dysplasia, transient tachypnea of the newborn, meconium aspiration syndrome, and after the effects of treatments given to newborn infants with lung diseases.
The TremoFlo device uses the forced oscillation technique during spontaneous infant breathing and notably does not require any sedation to perform. The forced oscillation technique measures lung function by superimposing a gentle multi-frequency airwave onto the infant's respiratory airflow while the infant breathes spontaneously. Only a short period of breathing is required to obtain a reliable measurement of airway resistance and reactance. Oscillometry has been successfully utilized to quantify lung function in asthmatic children and adults with chronic obstructive pulmonary disease, but never previously in infants. This proposal brings this non-invasive technique of measuring lung function to the neonatal population to identify changes in respiratory mechanics between term and pre-term gestations and quantify fluctuations in infant lung function in response to disease progression and therapeutic intervention. The ease of oscillometry that only requires tidal breathing eliminates the need for patient cooperation and maneuvers that previously excluded lung function testing in the neonatal intensive care unit. This proposal will evaluate the feasibility and clinical value of oscillometry in newborns, both to detect changes in premature compared to full-term gestations as well as disease cohorts by introducing functional measures of lung function to bedside care.
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Todellinen)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Alabama
-
Birmingham, Alabama, Yhdysvallat, 35249
- University of Alabama at Birmingham
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Infants with gestational age at least 22 weeks at birth
- Infants off ventilator/continuous positive airway pressure ≥ 12 hours
- Infants whose parents/legal guardians have provided consent
Exclusion Criteria:
- Infants with major malformation
- Infants with a neuromuscular condition that affects respiration
- Infants with terminal illness
- Infants with a decision made to withhold or limit support
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Diagnostiikka
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseiden lukumäärä
Aseet ja interventiot
Osallistujaryhmä / ArmOsallistujaryhmä / Arm |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
Kokeellinen: Non-invasive forced airway oscillometry
Analyze lung function using forced airway oscillometry in preterm infants and term infants with and without lung disease with both cross-sectional and longitudinal comparisons. Aim 1: Lung function in term and preterm infants without lung disease (anticipated n=264) Aim 2: Lung function in preterm infants with respiratory distress syndrome (RDS) who develop bronchopulmonary dysplasia (BPD) and preterm infants with RDS who do not develop BPD (anticipated n=264) Aim 3: Lung function measurements in infants with common neonatal lung diseases (including RDS, BPD, meconium aspiration syndrome, and transient tachypnea of the newborn) and controls without lung disease (anticipated n=570) Aim 4: Lung function in infants with lung disease before and after common therapeutic interventions |
This is a non-invasive device will measure lung function in spontaneously breathing infants. Infants will have a cushioned mask placed on his/her face and the device will take measurements as the infant breathes normally. |
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Area Under the Reactance Curve (AXR)
Aikaikkuna: 40 weeks' postmenstrual age or discharge until 2 years
|
AXR as the measure of overall measure of reactance of the respiratory system quantified by oscillometry and measured in cmH2O/L |
40 weeks' postmenstrual age or discharge until 2 years
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
R7-20
Aikaikkuna: 40 weeks' postmenstrual age or discharge until 2 years
|
Difference between resistance at 7 Hz and 20 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L |
40 weeks' postmenstrual age or discharge until 2 years
|
|
R7
Aikaikkuna: 40 weeks' postmenstrual age or discharge until 2 years
|
Resistance at 7 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L |
40 weeks' postmenstrual age or discharge until 2 years
|
|
X7
Aikaikkuna: 40 weeks' postmenstrual age or discharge until 2 years
|
Reactance at 7 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L |
40 weeks' postmenstrual age or discharge until 2 years
|
|
Longer-term Pulmonary Outcomes
Aikaikkuna: Up to 2 years
|
Severe morbidity: respiratory support including or CPAP or ventilation or tracheostomy; moderate morbidity: supplemental oxygen; treatment with daily pulmonary medications; ≥2 rehospitalizations for respiratory illness; ≥3 episodes of wheeze ≥2 weeks apart; mild morbidity: treatment with intermittent pulmonary medications; ≥2 episodes of wheeze ≥2 weeks apart; ≥2 medical visits for respiratory illness ≥2 weeks apart; 1 rehospitalization for respiratory illness) |
Up to 2 years
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Yhteistyökumppanit
Yhteistyökumppanit
Tutkijat
Tutkijat
- Opintojohtaja: Namasivayam Ambalavanan, MD, University of Alabama at Birmingham
Julkaisuja ja hyödyllisiä linkkejä
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Ensisijainen valmistuminen
Opintojen valmistuminen (Arvioitu)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
- Urogenitaaliset sairaudet
- Naisten virtsa- ja sukupuolielinten sairaudet ja raskauden komplikaatiot
- Raskauden komplikaatiot
- Hengityselinten sairaudet
- Keuhkosairaudet
- Hengityshäiriöt
- Sikiön sairaudet
- Merkit ja oireet, Hengityselimet
- Keuhkovaurio
- Hengityslaitteen aiheuttama keuhkovaurio
- Hengitysvaikeusoireyhtymä
- Synnynnäiset, perinnölliset ja vastasyntyneiden sairaudet ja poikkeavuudet
- Patologiset tilat, merkit ja oireet
- Merkit ja oireet
- Tachypnea
- Hengitysvaikeusoireyhtymä, vastasyntynyt
- Vauva, Keskoset, Sairaudet
- Bronkopulmonaalinen dysplasia
- Vauva, vastasyntynyt, sairaudet
- Vastasyntyneen ohimenevä takypnea
- Mekonium-aspiraatio-oireyhtymä
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- IRB-300000296
- K23HL157618 (Yhdysvaltain NIH-apuraha/sopimus)
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Yhdysvalloissa valmistettu ja sieltä viety tuote
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .