Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Función pulmonar mediante oscilometría forzada no invasiva (PUFFOR)

19 de octubre de 2026 actualizado por: Colm Travers, University of Alabama at Birmingham

Función pulmonar utilizando pruebas respiratorias de oscilometría forzada no invasiva: un estudio observacional prospectivo

The purpose of this observational study is to measure pulmonary function in term and preterm infants with and without pulmonary disease including respiratory distress syndrome, bronchopulmonary dysplasia, transient tachypnea of the newborn, meconium aspiration syndrome, and response to treatments given to newborn infants with lung diseases using a non-invasive airway oscillometry system.

Descripción general del estudio

Estado

Activo, no reclutando

Condiciones

Intervención / Tratamiento

Descripción detallada

TremoFlo™ N-100 (For Investigational Use Only) Airwave Oscillometry System™ (THORASYS Thoracic Medical Systems Inc. Montreal, Quebec, Canada) is a technology for measuring lung mechanics without patient effort. Pulmonary function testing using flow-volume and lung volumes is one of the most widely used tests to objectively measure lung function in adults. Such measurements are dependent on effort and coordination by the patient which is not possible for newborn infants. The minimum age for spirometry is typically 6 years to master the technique. Therefore, newborn infants usually require forced exhalation, flow interruption, and often sedation/anesthesia in order to obtain accurate pulmonary function measurements. Infant pulmonary function testing can be time-consuming and expensive to perform in newborn infants. This has limited the utilization of this potentially informative method of studying lung function. Measurements of lung function will be particularly informative during transition from having lungs filled with fluid during intra-uterine life to having lungs filled with air in extra-uterine life in preterm and term babies without lung disease, as well as in newborn infants with lung diseases including respiratory distress syndrome, bronchopulmonary dysplasia, transient tachypnea of the newborn, meconium aspiration syndrome, and after the effects of treatments given to newborn infants with lung diseases.

The TremoFlo device uses the forced oscillation technique during spontaneous infant breathing and notably does not require any sedation to perform. The forced oscillation technique measures lung function by superimposing a gentle multi-frequency airwave onto the infant's respiratory airflow while the infant breathes spontaneously. Only a short period of breathing is required to obtain a reliable measurement of airway resistance and reactance. Oscillometry has been successfully utilized to quantify lung function in asthmatic children and adults with chronic obstructive pulmonary disease, but never previously in infants. This proposal brings this non-invasive technique of measuring lung function to the neonatal population to identify changes in respiratory mechanics between term and pre-term gestations and quantify fluctuations in infant lung function in response to disease progression and therapeutic intervention. The ease of oscillometry that only requires tidal breathing eliminates the need for patient cooperation and maneuvers that previously excluded lung function testing in the neonatal intensive care unit. This proposal will evaluate the feasibility and clinical value of oscillometry in newborns, both to detect changes in premature compared to full-term gestations as well as disease cohorts by introducing functional measures of lung function to bedside care.

Tipo de estudio

Intervencionista

Inscripción (Actual)

600

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Alabama
      • Birmingham, Alabama, Estados Unidos, 35249
        • University of Alabama at Birmingham

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

1 día a 2 años (Niño)

Acepta Voluntarios Saludables

Sí

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Infants with gestational age at least 22 weeks at birth
  • Infants off ventilator/continuous positive airway pressure ≥ 12 hours
  • Infants whose parents/legal guardians have provided consent

Exclusion Criteria:

  • Infants with major malformation
  • Infants with a neuromuscular condition that affects respiration
  • Infants with terminal illness
  • Infants with a decision made to withhold or limit support

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Diagnóstico
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Non-invasive forced airway oscillometry

Analyze lung function using forced airway oscillometry in preterm infants and term infants with and without lung disease with both cross-sectional and longitudinal comparisons.

Aim 1: Lung function in term and preterm infants without lung disease (anticipated n=264) Aim 2: Lung function in preterm infants with respiratory distress syndrome (RDS) who develop bronchopulmonary dysplasia (BPD) and preterm infants with RDS who do not develop BPD (anticipated n=264) Aim 3: Lung function measurements in infants with common neonatal lung diseases (including RDS, BPD, meconium aspiration syndrome, and transient tachypnea of the newborn) and controls without lung disease (anticipated n=570) Aim 4: Lung function in infants with lung disease before and after common therapeutic interventions

This is a non-invasive device will measure lung function in spontaneously breathing infants. Infants will have a cushioned mask placed on his/her face and the device will take measurements as the infant breathes normally.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Area Under the Reactance Curve (AXR)
Periodo de tiempo: 40 weeks' postmenstrual age or discharge until 2 years

AXR as the measure of overall measure of reactance of the respiratory system quantified by oscillometry and measured in cmH2O/L

40 weeks' postmenstrual age or discharge until 2 years

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
R7-20
Periodo de tiempo: 40 weeks' postmenstrual age or discharge until 2 years

Difference between resistance at 7 Hz and 20 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L

40 weeks' postmenstrual age or discharge until 2 years
R7
Periodo de tiempo: 40 weeks' postmenstrual age or discharge until 2 years

Resistance at 7 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L

40 weeks' postmenstrual age or discharge until 2 years
X7
Periodo de tiempo: 40 weeks' postmenstrual age or discharge until 2 years

Reactance at 7 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L

40 weeks' postmenstrual age or discharge until 2 years
Longer-term Pulmonary Outcomes
Periodo de tiempo: Up to 2 years

Severe morbidity: respiratory support including or CPAP or ventilation or tracheostomy; moderate morbidity: supplemental oxygen; treatment with daily pulmonary medications; ≥2 rehospitalizations for respiratory illness; ≥3 episodes of wheeze ≥2 weeks apart; mild morbidity: treatment with intermittent pulmonary medications; ≥2 episodes of wheeze ≥2 weeks apart; ≥2 medical visits for respiratory illness ≥2 weeks apart; 1 rehospitalization for respiratory illness)

Up to 2 years

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Investigadores

  • Director de estudio: Namasivayam Ambalavanan, MD, University of Alabama at Birmingham

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

6 de diciembre de 2017

Finalización primaria (Actual)

21 de octubre de 2024

Finalización del estudio (Estimado)

1 de mayo de 2027

Fechas de registro del estudio

Enviado por primera vez

10 de noviembre de 2017

Primero enviado que cumplió con los criterios de control de calidad

14 de noviembre de 2017

Publicado por primera vez (Actual)

17 de noviembre de 2017

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

12 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

19 de octubre de 2026

Última verificación

1 de octubre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • IRB-300000296
  • K23HL157618 (Subvención/contrato del NIH de EE. UU.)

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

producto fabricado y exportado desde los EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .