Função pulmonar usando oscilometria forçada não invasiva (PUFFOR)
Função Pulmonar Usando Teste Respiratório de Oscilometria Forçada Não Invasiva: Um Estudo Observacional Prospectivo
The purpose of this observational study is to measure pulmonary function in term and preterm infants with and without pulmonary disease including respiratory distress syndrome, bronchopulmonary dysplasia, transient tachypnea of the newborn, meconium aspiration syndrome, and response to treatments given to newborn infants with lung diseases using a non-invasive airway oscillometry system.
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
TremoFlo™ N-100 (For Investigational Use Only) Airwave Oscillometry System™ (THORASYS Thoracic Medical Systems Inc. Montreal, Quebec, Canada) is a technology for measuring lung mechanics without patient effort. Pulmonary function testing using flow-volume and lung volumes is one of the most widely used tests to objectively measure lung function in adults. Such measurements are dependent on effort and coordination by the patient which is not possible for newborn infants. The minimum age for spirometry is typically 6 years to master the technique. Therefore, newborn infants usually require forced exhalation, flow interruption, and often sedation/anesthesia in order to obtain accurate pulmonary function measurements. Infant pulmonary function testing can be time-consuming and expensive to perform in newborn infants. This has limited the utilization of this potentially informative method of studying lung function. Measurements of lung function will be particularly informative during transition from having lungs filled with fluid during intra-uterine life to having lungs filled with air in extra-uterine life in preterm and term babies without lung disease, as well as in newborn infants with lung diseases including respiratory distress syndrome, bronchopulmonary dysplasia, transient tachypnea of the newborn, meconium aspiration syndrome, and after the effects of treatments given to newborn infants with lung diseases.
The TremoFlo device uses the forced oscillation technique during spontaneous infant breathing and notably does not require any sedation to perform. The forced oscillation technique measures lung function by superimposing a gentle multi-frequency airwave onto the infant's respiratory airflow while the infant breathes spontaneously. Only a short period of breathing is required to obtain a reliable measurement of airway resistance and reactance. Oscillometry has been successfully utilized to quantify lung function in asthmatic children and adults with chronic obstructive pulmonary disease, but never previously in infants. This proposal brings this non-invasive technique of measuring lung function to the neonatal population to identify changes in respiratory mechanics between term and pre-term gestations and quantify fluctuations in infant lung function in response to disease progression and therapeutic intervention. The ease of oscillometry that only requires tidal breathing eliminates the need for patient cooperation and maneuvers that previously excluded lung function testing in the neonatal intensive care unit. This proposal will evaluate the feasibility and clinical value of oscillometry in newborns, both to detect changes in premature compared to full-term gestations as well as disease cohorts by introducing functional measures of lung function to bedside care.
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Alabama
-
Birmingham, Alabama, Estados Unidos, 35249
- University of Alabama at Birmingham
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Infants with gestational age at least 22 weeks at birth
- Infants off ventilator/continuous positive airway pressure ≥ 12 hours
- Infants whose parents/legal guardians have provided consent
Exclusion Criteria:
- Infants with major malformation
- Infants with a neuromuscular condition that affects respiration
- Infants with terminal illness
- Infants with a decision made to withhold or limit support
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Diagnóstico
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Número de braços
Armas e Intervenções
Grupo de Participantes / BraçoGrupo de Participantes / Braço |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Experimental: Non-invasive forced airway oscillometry
Analyze lung function using forced airway oscillometry in preterm infants and term infants with and without lung disease with both cross-sectional and longitudinal comparisons. Aim 1: Lung function in term and preterm infants without lung disease (anticipated n=264) Aim 2: Lung function in preterm infants with respiratory distress syndrome (RDS) who develop bronchopulmonary dysplasia (BPD) and preterm infants with RDS who do not develop BPD (anticipated n=264) Aim 3: Lung function measurements in infants with common neonatal lung diseases (including RDS, BPD, meconium aspiration syndrome, and transient tachypnea of the newborn) and controls without lung disease (anticipated n=570) Aim 4: Lung function in infants with lung disease before and after common therapeutic interventions |
This is a non-invasive device will measure lung function in spontaneously breathing infants. Infants will have a cushioned mask placed on his/her face and the device will take measurements as the infant breathes normally. |
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Area Under the Reactance Curve (AXR)
Prazo: 40 weeks' postmenstrual age or discharge until 2 years
|
AXR as the measure of overall measure of reactance of the respiratory system quantified by oscillometry and measured in cmH2O/L |
40 weeks' postmenstrual age or discharge until 2 years
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
R7-20
Prazo: 40 weeks' postmenstrual age or discharge until 2 years
|
Difference between resistance at 7 Hz and 20 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L |
40 weeks' postmenstrual age or discharge until 2 years
|
|
R7
Prazo: 40 weeks' postmenstrual age or discharge until 2 years
|
Resistance at 7 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L |
40 weeks' postmenstrual age or discharge until 2 years
|
|
X7
Prazo: 40 weeks' postmenstrual age or discharge until 2 years
|
Reactance at 7 Hz in the respiratory system quantified by oscillometry and measured in cmH2O·s/L |
40 weeks' postmenstrual age or discharge until 2 years
|
|
Longer-term Pulmonary Outcomes
Prazo: Up to 2 years
|
Severe morbidity: respiratory support including or CPAP or ventilation or tracheostomy; moderate morbidity: supplemental oxygen; treatment with daily pulmonary medications; ≥2 rehospitalizations for respiratory illness; ≥3 episodes of wheeze ≥2 weeks apart; mild morbidity: treatment with intermittent pulmonary medications; ≥2 episodes of wheeze ≥2 weeks apart; ≥2 medical visits for respiratory illness ≥2 weeks apart; 1 rehospitalization for respiratory illness) |
Up to 2 years
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Colaboradores
Colaboradores
Investigadores
Investigadores
- Diretor de estudo: Namasivayam Ambalavanan, MD, University of Alabama at Birmingham
Publicações e links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Estimado)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
- Doenças urogenitais
- Doenças urogenitais femininas e complicações na gravidez
- Complicações na Gravidez
- Doenças Respiratórias
- Doenças pulmonares
- Distúrbios Respiratórios
- Doenças Fetais
- Sinais e Sintomas Respiratórios
- Lesão pulmonar
- Lesão Pulmonar Induzida por Ventilador
- Síndrome do Desconforto Respiratório
- Doenças e Anormalidades Congênitas, Hereditárias e Neonatais
- Condições Patológicas, Sinais e Sintomas
- Sinais e sintomas
- Taquipnéia
- Síndrome do Desconforto Respiratório do Recém-Nascido
- Lactente, Prematuro, Doenças
- Displasia broncopulmonar
- Lactente, Recém Nascido, Doenças
- Taquipnéia transitória do recém-nascido
- Síndrome de Aspiração de Mecônio
Outros números de identificação do estudo
Outros números de identificação do estudo
- IRB-300000296
- K23HL157618 (Concessão/Contrato do NIH dos EUA)
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .