- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT07300852
DSLT normaaliaineen glaukoomaan (NTG) sairastavien aasialaisten silmissä
DSLT:n tehokkuus aasialaisilla normaali jänniteglaukooma-potilailla
The goal of this clinical trial is to evaluate the efficacy of direct selective laser trabeculoplasty (DSLT) or laser treatment in Asian patients with normal tension glaucoma. The main question it aims to answer is:
Does the DSLT reduce intraocular pressure (IOP) and medication use in Asian NTG subjects? Participants will attend routine follow-up visits with their eye surgeon and glaucoma testing such as optical coherence tomography (OCT) imaging and visual field test(s) after the laser study treatment.
Tutkimuksen yleiskatsaus
Tila
Interventio / Hoito
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
California
-
San Jose, California, Yhdysvallat, 95116
- Ngoc Nguyen M.D.
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Asian descent
- NTG diagnosis: glaucomatous optic neuropathy in patients with IOP measurements consistently lower than 21 mmHg
- Mean deviation (MD) of the visual field between 0 to -12dB
- No significant central vision loss within 5 degrees within 5th percentile
- Age ≥20 years
- NTG patients who are medically controlled on 1-3 medications and safe to wash out or IOP is still insufficient from medications and safe to washout
- Shaffer grade II or more on 3 of the 4 quadrants
- Central corneal thickness (CCT) 450-600µm
- All participants are able to provide written informed consent before participation
Exclusion Criteria:
- Angle closure glaucoma or narrow angle status post laser peripheral iridotomy (LPI), or any other open angle glaucoma excluding NTG
- History of SLT within last 2 years
- History intraocular surgery including refractive surgery, except for history of cataract surgery that has been greater than 1 year
- Patients anticipating cataract surgery during the study follow-up period
- Unable to have DSLT procedure due to pre-limbal findings
- Any presence of relevant ocular diseases including retinal disease with no confirmed cure
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: DSLT Treatment Arm
Participants will receive Direct Selective Laser Trabeculoplasty (DSLT) using the BELKIN Vision Eagle device. The procedure is performed without a contact lens and delivers non-contact laser energy to the trabecular meshwork to lower intraocular pressure. All participants undergo standard pre- and post-procedure evaluations, including IOP measurements, visual field testing, and OCT imaging. |
Direct Selective Laser Trabeculoplasty (DSLT) is a non-contact laser procedure that delivers energy to the trabecular meshwork without the need for a gonioscopy lens. The BELKIN Vision Eagle device automatically aligns and applies laser pulses to lower intraocular pressure in subjects with normal tension glaucoma. All participants receive a single DSLT treatment followed by routine post-procedure evaluations including IOP checks, visual field testing, and OCT imaging.
Muut nimet:
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Change in Intraocular Pressure (IOP)
Aikaikkuna: 12 months post procedure
|
Absolute change in washed-out intraocular pressure (IOP) at 12 months compared to washed-out baseline IOP. Following a 6-week washout at baseline and again at month 11, IOP will be measured using standard tonometry to assess the effect of Direct Selective Laser Trabeculoplasty (DSLT) on pressure reduction. |
12 months post procedure
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Number of Glaucoma Medications Reduced
Aikaikkuna: 12 months post-procedure
|
Change in the number of topical glaucoma medications required to control intraocular pressure at 11 months compared to baseline, to evaluate whether DSLT decreases medication burden. |
12 months post-procedure
|
|
Proportion of Patients Who Are Medication-Free
Aikaikkuna: 12 months post-procedure
|
Proportion of participants who require zero topical glaucoma medications at 11 months after DSLT treatment. |
12 months post-procedure
|
Yhteistyökumppanit ja tutkijat
Sponsori
Yhteistyökumppanit
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- NTG_DSLT-001
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
IPD-suunnitelman kuvaus
There is no plan to share individual participant data (IPD) for this study. The sample size is small and sharing de-identified datasets may not adequately protect participant privacy.
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Yhdysvalloissa valmistettu ja sieltä viety tuote
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .