LungVision AI-Augmented Fluoroscopic Navigation for Intraoperative Pulmonary Nodule Localization
Clinical Feasibility, Localization Accuracy, and Safety of the LungVision System for Intraoperative Localization of Small Pulmonary Nodules During Thoracoscopic Surgery: A Prospective Single-Center Pilot Study
Tutkimuksen yleiskatsaus
Tila
Interventio / Hoito
Yksityiskohtainen kuvaus
Lung cancer is the leading cause of cancer-related mortality worldwide, and accurate intraoperative localization of small pulmonary nodules is critical for guiding thoracoscopic resection. Conventional localization methods, including CT-guided percutaneous dye injection and virtual bronchoscopic navigation, carry limitations such as radiation exposure, pneumothorax risk, and dependence on pre-procedural planning without real-time intraoperative feedback.
The LungVision system (Body Vision Medical, Israel) is an AI-augmented fluoroscopic bronchoscopic navigation platform that integrates preoperative CT imaging with real-time C-arm fluoroscopy via machine learning-based image fusion. The system provides continuous intraoperative tool-tip tracking and lesion overlay without additional radiation beyond standard fluoroscopy, enabling real-time navigational feedback during bronchoscopic procedures.
This prospective, single-center, single-arm pilot study was conducted at the Department of Thoracic Surgery, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan. A total of 14 patients with small pulmonary nodules requiring preoperative localization prior to video-assisted thoracoscopic surgery (VATS) were enrolled between January and December 2024. Each patient underwent dual localization: preoperative marking via CT-guided percutaneous dye injection or virtual bronchoscopic navigation (Broncus Archimedes Software System), followed by intraoperative localization using the LungVision system with ICG dye injection under fluoroscopic guidance.
The primary outcome was localization success rate, defined as the proportion of patients achieving fluoroscopic tool-in-lesion confirmation using the LungVision system. Secondary outcomes included complete resection rate (confirmed by pathological examination), navigation time, total operative time, and perioperative complication rate assessed up to 30 days postoperatively. Thoracoscopic resection was performed based on the combined localization findings, and all resected specimens were submitted for histopathological analysis.
This study was approved by the Institutional Review Board of Tri-Service General Hospital (IRB No.: A202303004) and was conducted in accordance with the Declaration of Helsinki. Written informed consent was obtained from all participants prior to enrollment.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Taiwan
-
Taipei, Taiwan, Taiwan, 114202
- Tri-Service General Hospital
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Kuvaus
Inclusion Criteria:
- Age 18-65 years
- Scheduled to undergo thoracoscopic resection for solitary, subsolid, or ground-glass pulmonary nodules requiring localization
- Lesion characteristics and CT imaging indicating need for preoperative localization, as determined by the attending surgeon
- Able and willing to complete the study protocol
- Able to provide written informed consent
Exclusion Criteria:
- Age >65 years
- Pregnancy
- Bleeding tendency or current use of anticoagulants
- Impaired consciousness or inability to communicate
- Cognitive impairment precluding autonomous consent
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: LungVision AI-Augmented Fluoroscopic Navigation
Patients underwent intraoperative pulmonary nodule localization using the LungVision system (Body Vision Medical, Israel), an AI-augmented fluoroscopic bronchoscopic navigation platform that integrates preoperative CT imaging with real-time C-arm fluoroscopy via machine learning-based image fusion.
Under bronchoscopic guidance, the navigational tool was advanced toward the target lesion, and tool-in-lesion confirmation was verified under fluoroscopic overlay.
Upon successful localization, indocyanine green (ICG) dye was injected transbronchially to mark the target nodule.
All patients additionally received preoperative localization via CT-guided percutaneous dye injection or virtual bronchoscopic navigation (Broncus Archimedes Software System) as part of the dual-localization protocol.
Subsequent video-assisted thoracoscopic surgery (VATS) was performed based on the combined localization findings.
|
The LungVision system is an AI-augmented fluoroscopic bronchoscopic navigation platform developed by Body Vision Medical (Israel).
The system integrates preoperative CT imaging with real-time intraoperative C-arm fluoroscopy using machine learning-based image fusion to provide continuous tool-tip tracking and lesion overlay.
The system guides the bronchoscopic navigational tool to the target pulmonary nodule without additional radiation beyond standard fluoroscopy.
Upon tool-in-lesion confirmation, indocyanine green (ICG) dye is injected transbronchially for surgical marking prior to thoracoscopic resection.
As part of the dual-localization protocol, all patients received preoperative localization via one of the following methods prior to LungVision intraoperative navigation: (1) CT-guided percutaneous dye injection using methylene blue, or (2) virtual bronchoscopic navigation using the Broncus Archimedes Software System.
The choice of preoperative localization method was determined by the operating surgeon based on nodule characteristics and clinical judgment.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Localization Success Rate
Aikaikkuna: Intraoperative
|
Proportion of patients in whom successful intraoperative pulmonary nodule localization was achieved using the LungVision system, defined as fluoroscopic tool-in-lesion confirmation verified by the operating surgeon based on real-time AI-augmented fluoroscopic overlay.
Localization was considered successful when the navigational tool tip was confirmed to be positioned within or immediately adjacent to the target nodule under fluoroscopic guidance prior to dye injection.
|
Intraoperative
|
Yhteistyökumppanit ja tutkijat
Sponsori
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- TSGH-LV-2026
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
IPD-suunnitelman kuvaus
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .
Kliiniset tutkimukset Karsinooma, ei-pienisoluinen keuhko
-
Everest Medicines (Beijing) Co., Ltd.Ei vielä rekrytointiaSquamous Non-Small Cell Lung Cancer sqNSCLC
-
Taichung Veterans General HospitalValmisKardiotoksisuus | Pienisoluista poikkeava keuhkosyöpä (MeSH-termi: Carcinoma, Non-Small-Cell Lung) | Lääkeaineisiin liittyvät sivuvaikutukset ja haittareaktiot (MeSH-termi) | Egfr-tyrosiinikinaasin estäjäTaiwan
-
AstraZenecaValmisEdistynyt kastraattiresistentti eturauhassyöpä CRPC | Squamous Non-Small Cell Lung Cancer sqNSCLC | Kolminkertainen negatiivinen rintasyöpä TNBCEspanja, Kanada, Yhdysvallat, Yhdistynyt kuningaskunta
-
Fondazione del Piemonte per l'OncologiaRekrytointiRintasyöpä | Munasarjasyöpä | Peräsuolen syöpä | Melanooma (ihosyöpä) | Pienisoluista poikkeava keuhkosyöpä (MeSH-termi: Carcinoma, Non-Small-Cell Lung)Italia
Kliiniset tutkimukset LungVision System
-
Martin BerliBern University of Applied SciencesValmisAmputaatio; Traumaattinen, käsiSveitsi
-
Reciprocal LabsCalifornia HealthCare FoundationValmis
-
Children's Oncology GroupNational Cancer Institute (NCI); NovoCure Ltd.Aktiivinen, ei rekrytointiPahanlaatuinen gliooma | Ependymooma | Diffuusi sisäinen Pontine GlioomaYhdysvallat
-
EmStop IncBright Research PartnersValmisAorttaläppästenoosiYhdysvallat
-
Boston Scientific CorporationAktiivinen, ei rekrytointiSydän-ja verisuonitaudit | Toiminnallinen mitraalinen regurgitaatio | Mitraaliläpän sairausAustralia, Yhdysvallat
-
NightWareRationalPsych; Center for International Emergency Medical ServicesValmisNukkumishäiriö | Nukkumisen alkamis- ja ylläpitohäiriöt | Stressihäiriö | Taistele häiriöitä vastaan | Painajainen | Posttraumaattinen stressihäiriö | Painajaisia, REM-unityyppi | Krooniseen trauman jälkeiseen stressihäiriöön liittyvät painajaisetYhdysvallat
-
BlueWind MedicalAktiivinen, ei rekrytointi
-
Kerastem Technologies, LLCValmisHiustenlähtö, androgeneettinenYhdysvallat
-
Argon Medical DevicesNAMSAKeskeytettySydän-ja verisuonitaudit | Laskimotromboembolia | Keuhkoveritulppa | Akuutti keuhkoemboliaYhdysvallat
-
Intervene, Inc.LopetettuKrooninen laskimoiden vajaatoiminta (CVI) | Syvä laskimorefluksiYhdysvallat