Photon-Counting Cardiac CT in Post-PCI Patients
Diagnostic Performance and Prognostic Value of Multiparametric Photon-Counting Cardiac CT in Patients With Prior Coronary Stent Implantation: A Prospective Cohort Study
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Description détaillée
In the long-term management of patients after percutaneous coronary intervention, imaging assessment has become an indispensable tool for detecting in-stent restenosis, progression of native coronary artery disease, myocardial ischemia, and adverse ventricular remodeling. Current guidelines recommend various imaging modalities, including coronary CT angiography for stent and vessel evaluation, stress perfusion imaging for myocardial ischemia, and cardiac magnetic resonance for tissue characterization and ventricular function. However, traditional follow-up strategies require multiple separate examinations, which entail repeated contrast agent administration, cumulative radiation exposure, prolonged diagnostic timelines, and fragmented pathophysiological assessment. How to simultaneously evaluate coronary anatomy, myocardial iodine distribution, extracellular volume, and cardiac function through a single examination is a major clinical need that remains to be addressed.
This study takes patients who have undergone percutaneous coronary intervention as the research subjects and adopts a prospective observational cohort design. The aim is to innovatively develop and validate a "one-stop" photon-counting computed tomography imaging framework. The PCCT ONE-STEP protocol implies that multiple assessments are acquired through a single intravenous contrast injection and a single examination visit, including ultra-high-resolution coronary CT angiography for stent and native artery evaluation, spectral first-pass myocardial iodine distribution imaging, and low-dose delayed myocardial extracellular volume quantification. In a prespecified dose-controlled substudy, cardiac cine imaging and CT-derived strain analysis are additionally obtained.
The PCCT ONE-STEP protocol leverages the intrinsic spectral sensitivity and high spatial resolution of photon-counting detector technology. It can reduce the total volume of iodinated contrast medium and cumulative radiation dose compared with the sum of separate diagnostic examinations, while preserving or expanding the imaging content. By providing integrated coronary, myocardial iodine, extracellular volume, and functional phenotypes at a single visit, it has the potential to shorten the diagnostic work-up, decrease the incidence of contrast-associated adverse events, and improve patient throughput. The acquisition of multiple key imaging indicators enables individualized comprehensive assessment of post-PCI patients, supports the investigation of biological relevance through associations with circulating biomarkers, and facilitates the prediction of clinical ischemic and heart failure-related outcomes. The implementation of this study is expected to optimize the imaging pathway in the long-term care of patients after percutaneous coronary intervention.
Type d'étude
Type d'étude
Inscription (Estimé)
Inscription
Contacts et emplacements
Coordonnées de l'étude
Coordonnées de l'étude
- Nom: Xiaomeng Fan
- Numéro de téléphone: +8613203147909
- E-mail: fanxiaomeng@301hospital.com.cn
Sauvegarde des contacts de l'étude
- Nom: Xin Lou, Study Chair
- E-mail: xinlou301@sina.com
Lieux d'étude
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Chine, 100039
- Recrutement
- Chinese PLA General Hospital
-
Contact:
- Lou 新楼
- Numéro de téléphone: 18601226301
- E-mail: xinlou301@sina.com
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Age 18 years or older;
- History of percutaneous coronary intervention with implantation of at least one coronary stent;
- Ability to undergo iodinated contrast-enhanced CT;
- Ability and willingness to provide written informed consent.
Exclusion Criteria:
- Estimated glomerular filtration rate below the institutional threshold for contrast-enhanced CT, generally less than 30 mL/min/1.73 m², unless examination is clinically justified and approved according to institutional policy;
- Known severe hypersensitivity to iodinated contrast material that cannot be adequately managed using the institutional premedication protocol; Pregnancy or suspected pregnancy;
- Inability to provide informed consent or comply with study procedures;
- Severe respiratory inability to perform the required breath-hold.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Integrated Clinical Value of One-Stop Photon-Counting CT Phenotyping in Post-PCI Patients
Délai: 3 years
|
One-Stop photon-counting computed tomography examination in post-percutaneous coronary intervention patients performance, including coronary stent and native artery assessment, myocardial iodine distribution and extracellular volume quantification, functional strain imaging, diagnostic accuracy for angiographically significant in-stent restenosis (sensitivity, specificity, area under the curve), and prognostic association with major adverse cardiovascular events (cardiovascular death, nonfatal myocardial infarction, hospitalization for acute coronary syndrome, ischemia-driven revascularization,eg) over 12 months.
|
3 years
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Début de l'étude
Achèvement primaire (Estimé)
Achèvement primaire
Achèvement de l'étude (Estimé)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- One-Stop Photon CT in Post-PCI
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .