Photon-Counting Cardiac CT in Post-PCI Patients
Diagnostic Performance and Prognostic Value of Multiparametric Photon-Counting Cardiac CT in Patients With Prior Coronary Stent Implantation: A Prospective Cohort Study
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Descrizione dettagliata
In the long-term management of patients after percutaneous coronary intervention, imaging assessment has become an indispensable tool for detecting in-stent restenosis, progression of native coronary artery disease, myocardial ischemia, and adverse ventricular remodeling. Current guidelines recommend various imaging modalities, including coronary CT angiography for stent and vessel evaluation, stress perfusion imaging for myocardial ischemia, and cardiac magnetic resonance for tissue characterization and ventricular function. However, traditional follow-up strategies require multiple separate examinations, which entail repeated contrast agent administration, cumulative radiation exposure, prolonged diagnostic timelines, and fragmented pathophysiological assessment. How to simultaneously evaluate coronary anatomy, myocardial iodine distribution, extracellular volume, and cardiac function through a single examination is a major clinical need that remains to be addressed.
This study takes patients who have undergone percutaneous coronary intervention as the research subjects and adopts a prospective observational cohort design. The aim is to innovatively develop and validate a "one-stop" photon-counting computed tomography imaging framework. The PCCT ONE-STEP protocol implies that multiple assessments are acquired through a single intravenous contrast injection and a single examination visit, including ultra-high-resolution coronary CT angiography for stent and native artery evaluation, spectral first-pass myocardial iodine distribution imaging, and low-dose delayed myocardial extracellular volume quantification. In a prespecified dose-controlled substudy, cardiac cine imaging and CT-derived strain analysis are additionally obtained.
The PCCT ONE-STEP protocol leverages the intrinsic spectral sensitivity and high spatial resolution of photon-counting detector technology. It can reduce the total volume of iodinated contrast medium and cumulative radiation dose compared with the sum of separate diagnostic examinations, while preserving or expanding the imaging content. By providing integrated coronary, myocardial iodine, extracellular volume, and functional phenotypes at a single visit, it has the potential to shorten the diagnostic work-up, decrease the incidence of contrast-associated adverse events, and improve patient throughput. The acquisition of multiple key imaging indicators enables individualized comprehensive assessment of post-PCI patients, supports the investigation of biological relevance through associations with circulating biomarkers, and facilitates the prediction of clinical ischemic and heart failure-related outcomes. The implementation of this study is expected to optimize the imaging pathway in the long-term care of patients after percutaneous coronary intervention.
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Xiaomeng Fan
- Numero di telefono: +8613203147909
- Email: fanxiaomeng@301hospital.com.cn
Backup dei contatti dello studio
- Nome: Xin Lou, Study Chair
- Email: xinlou301@sina.com
Luoghi di studio
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Cina, 100039
- Reclutamento
- Chinese PLA General Hospital
-
Contatto:
- Lou 新楼
- Numero di telefono: 18601226301
- Email: xinlou301@sina.com
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Age 18 years or older;
- History of percutaneous coronary intervention with implantation of at least one coronary stent;
- Ability to undergo iodinated contrast-enhanced CT;
- Ability and willingness to provide written informed consent.
Exclusion Criteria:
- Estimated glomerular filtration rate below the institutional threshold for contrast-enhanced CT, generally less than 30 mL/min/1.73 m², unless examination is clinically justified and approved according to institutional policy;
- Known severe hypersensitivity to iodinated contrast material that cannot be adequately managed using the institutional premedication protocol; Pregnancy or suspected pregnancy;
- Inability to provide informed consent or comply with study procedures;
- Severe respiratory inability to perform the required breath-hold.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Integrated Clinical Value of One-Stop Photon-Counting CT Phenotyping in Post-PCI Patients
Lasso di tempo: 3 years
|
One-Stop photon-counting computed tomography examination in post-percutaneous coronary intervention patients performance, including coronary stent and native artery assessment, myocardial iodine distribution and extracellular volume quantification, functional strain imaging, diagnostic accuracy for angiographically significant in-stent restenosis (sensitivity, specificity, area under the curve), and prognostic association with major adverse cardiovascular events (cardiovascular death, nonfatal myocardial infarction, hospitalization for acute coronary syndrome, ischemia-driven revascularization,eg) over 12 months.
|
3 years
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- One-Stop Photon CT in Post-PCI
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .