Photon-Counting Cardiac CT in Post-PCI Patients
Diagnostic Performance and Prognostic Value of Multiparametric Photon-Counting Cardiac CT in Patients With Prior Coronary Stent Implantation: A Prospective Cohort Study
Przegląd badań
Status
Status
Warunki
Warunki
Szczegółowy opis
In the long-term management of patients after percutaneous coronary intervention, imaging assessment has become an indispensable tool for detecting in-stent restenosis, progression of native coronary artery disease, myocardial ischemia, and adverse ventricular remodeling. Current guidelines recommend various imaging modalities, including coronary CT angiography for stent and vessel evaluation, stress perfusion imaging for myocardial ischemia, and cardiac magnetic resonance for tissue characterization and ventricular function. However, traditional follow-up strategies require multiple separate examinations, which entail repeated contrast agent administration, cumulative radiation exposure, prolonged diagnostic timelines, and fragmented pathophysiological assessment. How to simultaneously evaluate coronary anatomy, myocardial iodine distribution, extracellular volume, and cardiac function through a single examination is a major clinical need that remains to be addressed.
This study takes patients who have undergone percutaneous coronary intervention as the research subjects and adopts a prospective observational cohort design. The aim is to innovatively develop and validate a "one-stop" photon-counting computed tomography imaging framework. The PCCT ONE-STEP protocol implies that multiple assessments are acquired through a single intravenous contrast injection and a single examination visit, including ultra-high-resolution coronary CT angiography for stent and native artery evaluation, spectral first-pass myocardial iodine distribution imaging, and low-dose delayed myocardial extracellular volume quantification. In a prespecified dose-controlled substudy, cardiac cine imaging and CT-derived strain analysis are additionally obtained.
The PCCT ONE-STEP protocol leverages the intrinsic spectral sensitivity and high spatial resolution of photon-counting detector technology. It can reduce the total volume of iodinated contrast medium and cumulative radiation dose compared with the sum of separate diagnostic examinations, while preserving or expanding the imaging content. By providing integrated coronary, myocardial iodine, extracellular volume, and functional phenotypes at a single visit, it has the potential to shorten the diagnostic work-up, decrease the incidence of contrast-associated adverse events, and improve patient throughput. The acquisition of multiple key imaging indicators enables individualized comprehensive assessment of post-PCI patients, supports the investigation of biological relevance through associations with circulating biomarkers, and facilitates the prediction of clinical ischemic and heart failure-related outcomes. The implementation of this study is expected to optimize the imaging pathway in the long-term care of patients after percutaneous coronary intervention.
Typ studiów
Typ studiów
Zapisy (Szacowany)
Zapisy
Kontakty i lokalizacje
Kontakt w sprawie studiów
Kontakt w sprawie studiów
- Nazwa: Xiaomeng Fan
- Numer telefonu: +8613203147909
- E-mail: fanxiaomeng@301hospital.com.cn
Kopia zapasowa kontaktu do badania
- Nazwa: Xin Lou, Study Chair
- E-mail: xinlou301@sina.com
Lokalizacje studiów
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Chiny, 100039
- Rekrutacyjny
- Chinese PLA General Hospital
-
Kontakt:
- Lou 新楼
- Numer telefonu: 18601226301
- E-mail: xinlou301@sina.com
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Age 18 years or older;
- History of percutaneous coronary intervention with implantation of at least one coronary stent;
- Ability to undergo iodinated contrast-enhanced CT;
- Ability and willingness to provide written informed consent.
Exclusion Criteria:
- Estimated glomerular filtration rate below the institutional threshold for contrast-enhanced CT, generally less than 30 mL/min/1.73 m², unless examination is clinically justified and approved according to institutional policy;
- Known severe hypersensitivity to iodinated contrast material that cannot be adequately managed using the institutional premedication protocol; Pregnancy or suspected pregnancy;
- Inability to provide informed consent or comply with study procedures;
- Severe respiratory inability to perform the required breath-hold.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Integrated Clinical Value of One-Stop Photon-Counting CT Phenotyping in Post-PCI Patients
Ramy czasowe: 3 years
|
One-Stop photon-counting computed tomography examination in post-percutaneous coronary intervention patients performance, including coronary stent and native artery assessment, myocardial iodine distribution and extracellular volume quantification, functional strain imaging, diagnostic accuracy for angiographically significant in-stent restenosis (sensitivity, specificity, area under the curve), and prognostic association with major adverse cardiovascular events (cardiovascular death, nonfatal myocardial infarction, hospitalization for acute coronary syndrome, ischemia-driven revascularization,eg) over 12 months.
|
3 years
|
Współpracownicy i badacze
Sponsor
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Szacowany)
Zakończenie podstawowe
Ukończenie studiów (Szacowany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- One-Stop Photon CT in Post-PCI
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .