Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Photon-Counting Cardiac CT in Post-PCI Patients

10 de agosto de 2026 actualizado por: Xin Lou, Chinese PLA General Hospital

Diagnostic Performance and Prognostic Value of Multiparametric Photon-Counting Cardiac CT in Patients With Prior Coronary Stent Implantation: A Prospective Cohort Study

This study takes patients who have undergone percutaneous coronary intervention as the research subjects and employs a prospective observational cohort design, aiming to develop and validate a "one-stop" photon-counting computed tomography imaging framework. The one-stop PCCT protocol implies that multiple assessments are acquired through a single examination, including coronary CT angiography for stent and native artery evaluation, resting first-pass myocardial iodine distribution imaging, and delayed myocardial extracellular volume quantification, with cardiac cine imaging performed in a prespecified dose-controlled substudy.

Descripción general del estudio

Estado

Reclutamiento

Condiciones

Descripción detallada

In the long-term management of patients after percutaneous coronary intervention, imaging assessment has become an indispensable tool for detecting in-stent restenosis, progression of native coronary artery disease, myocardial ischemia, and adverse ventricular remodeling. Current guidelines recommend various imaging modalities, including coronary CT angiography for stent and vessel evaluation, stress perfusion imaging for myocardial ischemia, and cardiac magnetic resonance for tissue characterization and ventricular function. However, traditional follow-up strategies require multiple separate examinations, which entail repeated contrast agent administration, cumulative radiation exposure, prolonged diagnostic timelines, and fragmented pathophysiological assessment. How to simultaneously evaluate coronary anatomy, myocardial iodine distribution, extracellular volume, and cardiac function through a single examination is a major clinical need that remains to be addressed.

This study takes patients who have undergone percutaneous coronary intervention as the research subjects and adopts a prospective observational cohort design. The aim is to innovatively develop and validate a "one-stop" photon-counting computed tomography imaging framework. The PCCT ONE-STEP protocol implies that multiple assessments are acquired through a single intravenous contrast injection and a single examination visit, including ultra-high-resolution coronary CT angiography for stent and native artery evaluation, spectral first-pass myocardial iodine distribution imaging, and low-dose delayed myocardial extracellular volume quantification. In a prespecified dose-controlled substudy, cardiac cine imaging and CT-derived strain analysis are additionally obtained.

The PCCT ONE-STEP protocol leverages the intrinsic spectral sensitivity and high spatial resolution of photon-counting detector technology. It can reduce the total volume of iodinated contrast medium and cumulative radiation dose compared with the sum of separate diagnostic examinations, while preserving or expanding the imaging content. By providing integrated coronary, myocardial iodine, extracellular volume, and functional phenotypes at a single visit, it has the potential to shorten the diagnostic work-up, decrease the incidence of contrast-associated adverse events, and improve patient throughput. The acquisition of multiple key imaging indicators enables individualized comprehensive assessment of post-PCI patients, supports the investigation of biological relevance through associations with circulating biomarkers, and facilitates the prediction of clinical ischemic and heart failure-related outcomes. The implementation of this study is expected to optimize the imaging pathway in the long-term care of patients after percutaneous coronary intervention.

Tipo de estudio

De observación

Inscripción (Estimado)

800

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Copia de seguridad de contactos de estudio

Ubicaciones de estudio

    • Beijing Municipality
      • Beijing, Beijing Municipality, Porcelana, 100039
        • Reclutamiento
        • Chinese PLA General Hospital
        • Contacto:

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Método de muestreo

Muestra no probabilística

Población de estudio

Patients with cardiovascular diseases

Descripción

Inclusion Criteria:

  1. Age 18 years or older;
  2. History of percutaneous coronary intervention with implantation of at least one coronary stent;
  3. Ability to undergo iodinated contrast-enhanced CT;
  4. Ability and willingness to provide written informed consent.

Exclusion Criteria:

  1. Estimated glomerular filtration rate below the institutional threshold for contrast-enhanced CT, generally less than 30 mL/min/1.73 m², unless examination is clinically justified and approved according to institutional policy;
  2. Known severe hypersensitivity to iodinated contrast material that cannot be adequately managed using the institutional premedication protocol; Pregnancy or suspected pregnancy;
  3. Inability to provide informed consent or comply with study procedures;
  4. Severe respiratory inability to perform the required breath-hold.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Integrated Clinical Value of One-Stop Photon-Counting CT Phenotyping in Post-PCI Patients
Periodo de tiempo: 3 years
One-Stop photon-counting computed tomography examination in post-percutaneous coronary intervention patients performance, including coronary stent and native artery assessment, myocardial iodine distribution and extracellular volume quantification, functional strain imaging, diagnostic accuracy for angiographically significant in-stent restenosis (sensitivity, specificity, area under the curve), and prognostic association with major adverse cardiovascular events (cardiovascular death, nonfatal myocardial infarction, hospitalization for acute coronary syndrome, ischemia-driven revascularization,eg) over 12 months.
3 years

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

7 de enero de 2026

Finalización primaria (Estimado)

7 de enero de 2029

Finalización del estudio (Estimado)

7 de enero de 2029

Fechas de registro del estudio

Enviado por primera vez

10 de agosto de 2026

Primero enviado que cumplió con los criterios de control de calidad

10 de agosto de 2026

Publicado por primera vez (Actual)

13 de agosto de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

13 de agosto de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

10 de agosto de 2026

Última verificación

1 de enero de 2026

Más información

Términos relacionados con este estudio

Términos MeSH relevantes adicionales

Otros números de identificación del estudio

  • One-Stop Photon CT in Post-PCI

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .