Rotational Stability of the Acunex Vario Toric

3 novembre 2026 mis à jour par: Prim. Prof. Dr. Oliver Findl, MBA

Evaluation of the Rotational Stability of the Acunex Vario Toric Intraocular Lens

Efficacy of the rotational stability and astigmatism correction of a toric EDOF IOL, the Acunex Vario toric.

Aperçu de l'étude

Statut

Recrutement

Les conditions

Intervention / Traitement

Description détaillée

Recent advances in cataract surgery technology have transformed the procedure from a purely vision-restoring approach into a procedure for correcting presbyopia. Patients' resulting higher expectations regarding freedom from spectacles have led to advances in intraocular lens (IOL) technology in recent years. The implantation of a standard monofocal IOL designed to achieve emmetropia results in a high level of patient satisfaction with regard to distance vision. However, spectacles are still required for intermediate and near vision.

One approach to achieving freedom from spectacles at all distances is the use of multifocal IOLs. Compared with monofocal IOLs, however, these lenses are more frequently associated with photic phenomena such as glare and halos, as well as reduced contrast sensitivity. Another approach to minimize the need for spectacles is the use of IOLs with extended depth of focus (EDOF). These lenses feature an extended distance focus range that extends into the intermediate range, thereby offering high visual quality across a continuous focus range. Unlike trifocal IOLs, which split the light into different focal points, the extended focus of these IOLs is designed to improve contrast perception in the intermediate range and reduce light-related phenomena.

Furthermore, residual corneal astigmatism is an important factor in achieving post-operative freedom from spectacles, and its correction is necessary to achieve the best possible visual performance. The most widely used and effective approach to correcting corneal astigmatism is the implantation of a toric IOL. To ensure that these lenses achieve the desired effect, they must be positioned precisely along the intended axis, as any rotation of a toric IOL can reduce its ability to correct astigmatism.

Particularly in the case of IOLs designed to correct presbyopia, such as trifocal or EDOF lenses, it is therefore important to correct corneal astigmatism in order to achieve the best possible post-operative visual outcome. The aim of this study is therefore to analyze the efficacy and rotational stability of a toric EDOF IOL (Acunex Vario toric, AN6VT).

38 eyes from 38 patients will be included into the study, into each eye an AN6VT IOL will be implanted. Follow-up examinations will take place 1 hour, 1 week after surgery on the first eye and 1 week after surgery on the second eye, and 4-6 months post-operatively.

Type d'étude

Interventionnel

Inscription (Estimé)

38

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Johannes Zeilinger, MD
  • Numéro de téléphone: 57564 +43 1 91021
  • E-mail: office@viros.at

Sauvegarde des contacts de l'étude

  • Nom: Oliver Findl, Prim. Prof. Dr.
  • Numéro de téléphone: 57564 +43 1 91021
  • E-mail: office@viros.at

Lieux d'étude

      • Vienna, L'Autriche, 1140
        • Recrutement
        • Vienna Institute for Research in Ocular Surgery
        • Contact:
          • Johannes Zeilinger, MD
          • Numéro de téléphone: 57564 +43 1 91021
          • E-mail: office@viros.at
        • Contact:
          • Oliver Findl, Prim. Prof. Dr.
          • Numéro de téléphone: 57564 +43 1 91021
          • E-mail: office@viros.at

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

21 ans à 105 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Bilateral age-related cataract scheduled for cataract surgery
  • Age 21 or older
  • Predefined postoperative residual astigmatism to be < 0.5 D (calculated with Barrett total K toric calculator)
  • Calculated IOL power within the range of the investigated IOL
  • Pupil size ≥ 5 mm (in mydriasis)
  • Willingness to comply with the postoperative follow-up examination schedule
  • Written informed consent prior to surgery

Exclusion Criteria:

  • Previous ocular surgery or trauma
  • Extreme shallow anterior chamber
  • Uncontrolled systemic or ocular disease
  • Associated corneal pathologies (e.g., edema, scarring) or relevant other ophthalmic diseases that may result in altered visual outcome or lens stability (e.g., pseudoexfoliation syndrome, floppy iris syndrome, glaucoma, retinal disease)
  • Concurrent participation in another clinical investigation
  • Pregnancy or lactation (pregnancy test will be performed in women of reproductive age)

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Acunex Vario toric

Patient will recieve the Acunex Vario IOL during cataract surgery

The Acunex Vario toric IOL, toric EDOF IOL, will be implanted

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
IOL axis rotation
Délai: 12 monthes

The IOL axis rotation before and after cataract surgery will be analyzed with retroillumination photographs

12 monthes

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Distance visual acuity
Délai: 12 months

Uncorrected and corrected distance visual acuity before and after cataract surgery will be determined using ETDRS-charts in a distance of 4 metres

12 months
Intermediate visual acuity
Délai: 12 months

Uncorrected and corrected intermediate visual acuity before and after cataract surgery will be determined using ETDRS-charts in a distance of 66 centimetres

12 months
Refraction
Délai: 12 months

Refraction before and after cataract surgery will be determined using trial frame glasses and Jackson cross cylinders

12 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Les enquêteurs

  • Chercheur principal: Oliver Findl, Prim. Prof. Dr., Vienna Institute for Research in Ocular Surgery

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

27 mars 2026

Achèvement primaire (Estimé)

1 décembre 2027

Achèvement de l'étude (Estimé)

1 juillet 2028

Dates d'inscription aux études

Première soumission

3 novembre 2026

Première soumission répondant aux critères de contrôle qualité

3 novembre 2026

Première publication (Réel)

9 novembre 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

9 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

3 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • Acunex Vario toric

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .