Rotational Stability of the Acunex Vario Toric

3 de noviembre de 2026 actualizado por: Prim. Prof. Dr. Oliver Findl, MBA

Evaluation of the Rotational Stability of the Acunex Vario Toric Intraocular Lens

Efficacy of the rotational stability and astigmatism correction of a toric EDOF IOL, the Acunex Vario toric.

Descripción general del estudio

Estado

Reclutamiento

Condiciones

Intervención / Tratamiento

Descripción detallada

Recent advances in cataract surgery technology have transformed the procedure from a purely vision-restoring approach into a procedure for correcting presbyopia. Patients' resulting higher expectations regarding freedom from spectacles have led to advances in intraocular lens (IOL) technology in recent years. The implantation of a standard monofocal IOL designed to achieve emmetropia results in a high level of patient satisfaction with regard to distance vision. However, spectacles are still required for intermediate and near vision.

One approach to achieving freedom from spectacles at all distances is the use of multifocal IOLs. Compared with monofocal IOLs, however, these lenses are more frequently associated with photic phenomena such as glare and halos, as well as reduced contrast sensitivity. Another approach to minimize the need for spectacles is the use of IOLs with extended depth of focus (EDOF). These lenses feature an extended distance focus range that extends into the intermediate range, thereby offering high visual quality across a continuous focus range. Unlike trifocal IOLs, which split the light into different focal points, the extended focus of these IOLs is designed to improve contrast perception in the intermediate range and reduce light-related phenomena.

Furthermore, residual corneal astigmatism is an important factor in achieving post-operative freedom from spectacles, and its correction is necessary to achieve the best possible visual performance. The most widely used and effective approach to correcting corneal astigmatism is the implantation of a toric IOL. To ensure that these lenses achieve the desired effect, they must be positioned precisely along the intended axis, as any rotation of a toric IOL can reduce its ability to correct astigmatism.

Particularly in the case of IOLs designed to correct presbyopia, such as trifocal or EDOF lenses, it is therefore important to correct corneal astigmatism in order to achieve the best possible post-operative visual outcome. The aim of this study is therefore to analyze the efficacy and rotational stability of a toric EDOF IOL (Acunex Vario toric, AN6VT).

38 eyes from 38 patients will be included into the study, into each eye an AN6VT IOL will be implanted. Follow-up examinations will take place 1 hour, 1 week after surgery on the first eye and 1 week after surgery on the second eye, and 4-6 months post-operatively.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

38

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Johannes Zeilinger, MD
  • Número de teléfono: 57564 +43 1 91021
  • Correo electrónico: office@viros.at

Copia de seguridad de contactos de estudio

  • Nombre: Oliver Findl, Prim. Prof. Dr.
  • Número de teléfono: 57564 +43 1 91021
  • Correo electrónico: office@viros.at

Ubicaciones de estudio

      • Vienna, Austria, 1140
        • Reclutamiento
        • Vienna Institute for Research in Ocular Surgery
        • Contacto:
          • Johannes Zeilinger, MD
          • Número de teléfono: 57564 +43 1 91021
          • Correo electrónico: office@viros.at
        • Contacto:
          • Oliver Findl, Prim. Prof. Dr.
          • Número de teléfono: 57564 +43 1 91021
          • Correo electrónico: office@viros.at

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

21 años a 105 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Bilateral age-related cataract scheduled for cataract surgery
  • Age 21 or older
  • Predefined postoperative residual astigmatism to be < 0.5 D (calculated with Barrett total K toric calculator)
  • Calculated IOL power within the range of the investigated IOL
  • Pupil size ≥ 5 mm (in mydriasis)
  • Willingness to comply with the postoperative follow-up examination schedule
  • Written informed consent prior to surgery

Exclusion Criteria:

  • Previous ocular surgery or trauma
  • Extreme shallow anterior chamber
  • Uncontrolled systemic or ocular disease
  • Associated corneal pathologies (e.g., edema, scarring) or relevant other ophthalmic diseases that may result in altered visual outcome or lens stability (e.g., pseudoexfoliation syndrome, floppy iris syndrome, glaucoma, retinal disease)
  • Concurrent participation in another clinical investigation
  • Pregnancy or lactation (pregnancy test will be performed in women of reproductive age)

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Acunex Vario toric

Patient will recieve the Acunex Vario IOL during cataract surgery

The Acunex Vario toric IOL, toric EDOF IOL, will be implanted

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
IOL axis rotation
Periodo de tiempo: 12 monthes

The IOL axis rotation before and after cataract surgery will be analyzed with retroillumination photographs

12 monthes

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Distance visual acuity
Periodo de tiempo: 12 months

Uncorrected and corrected distance visual acuity before and after cataract surgery will be determined using ETDRS-charts in a distance of 4 metres

12 months
Intermediate visual acuity
Periodo de tiempo: 12 months

Uncorrected and corrected intermediate visual acuity before and after cataract surgery will be determined using ETDRS-charts in a distance of 66 centimetres

12 months
Refraction
Periodo de tiempo: 12 months

Refraction before and after cataract surgery will be determined using trial frame glasses and Jackson cross cylinders

12 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Oliver Findl, Prim. Prof. Dr., Vienna Institute for Research in Ocular Surgery

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

27 de marzo de 2026

Finalización primaria (Estimado)

1 de diciembre de 2027

Finalización del estudio (Estimado)

1 de julio de 2028

Fechas de registro del estudio

Enviado por primera vez

3 de noviembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

3 de noviembre de 2026

Publicado por primera vez (Actual)

9 de noviembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

9 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

3 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Términos MeSH relevantes adicionales

Otros números de identificación del estudio

  • Acunex Vario toric

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .