Rotational Stability of the Acunex Vario Toric

3. november 2026 oppdatert av: Prim. Prof. Dr. Oliver Findl, MBA

Evaluation of the Rotational Stability of the Acunex Vario Toric Intraocular Lens

Efficacy of the rotational stability and astigmatism correction of a toric EDOF IOL, the Acunex Vario toric.

Studieoversikt

Status

Rekruttering

Forhold

Intervensjon / Behandling

Detaljert beskrivelse

Recent advances in cataract surgery technology have transformed the procedure from a purely vision-restoring approach into a procedure for correcting presbyopia. Patients' resulting higher expectations regarding freedom from spectacles have led to advances in intraocular lens (IOL) technology in recent years. The implantation of a standard monofocal IOL designed to achieve emmetropia results in a high level of patient satisfaction with regard to distance vision. However, spectacles are still required for intermediate and near vision.

One approach to achieving freedom from spectacles at all distances is the use of multifocal IOLs. Compared with monofocal IOLs, however, these lenses are more frequently associated with photic phenomena such as glare and halos, as well as reduced contrast sensitivity. Another approach to minimize the need for spectacles is the use of IOLs with extended depth of focus (EDOF). These lenses feature an extended distance focus range that extends into the intermediate range, thereby offering high visual quality across a continuous focus range. Unlike trifocal IOLs, which split the light into different focal points, the extended focus of these IOLs is designed to improve contrast perception in the intermediate range and reduce light-related phenomena.

Furthermore, residual corneal astigmatism is an important factor in achieving post-operative freedom from spectacles, and its correction is necessary to achieve the best possible visual performance. The most widely used and effective approach to correcting corneal astigmatism is the implantation of a toric IOL. To ensure that these lenses achieve the desired effect, they must be positioned precisely along the intended axis, as any rotation of a toric IOL can reduce its ability to correct astigmatism.

Particularly in the case of IOLs designed to correct presbyopia, such as trifocal or EDOF lenses, it is therefore important to correct corneal astigmatism in order to achieve the best possible post-operative visual outcome. The aim of this study is therefore to analyze the efficacy and rotational stability of a toric EDOF IOL (Acunex Vario toric, AN6VT).

38 eyes from 38 patients will be included into the study, into each eye an AN6VT IOL will be implanted. Follow-up examinations will take place 1 hour, 1 week after surgery on the first eye and 1 week after surgery on the second eye, and 4-6 months post-operatively.

Studietype

Intervensjonell

Registrering (Antatt)

38

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

  • Navn: Johannes Zeilinger, MD
  • Telefonnummer: 57564 +43 1 91021
  • E-post: office@viros.at

Studer Kontakt Backup

  • Navn: Oliver Findl, Prim. Prof. Dr.
  • Telefonnummer: 57564 +43 1 91021
  • E-post: office@viros.at

Studiesteder

      • Vienna, Østerrike, 1140
        • Rekruttering
        • Vienna Institute for Research in Ocular Surgery
        • Ta kontakt med:
          • Johannes Zeilinger, MD
          • Telefonnummer: 57564 +43 1 91021
          • E-post: office@viros.at
        • Ta kontakt med:
          • Oliver Findl, Prim. Prof. Dr.
          • Telefonnummer: 57564 +43 1 91021
          • E-post: office@viros.at

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

21 år til 105 år (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Bilateral age-related cataract scheduled for cataract surgery
  • Age 21 or older
  • Predefined postoperative residual astigmatism to be < 0.5 D (calculated with Barrett total K toric calculator)
  • Calculated IOL power within the range of the investigated IOL
  • Pupil size ≥ 5 mm (in mydriasis)
  • Willingness to comply with the postoperative follow-up examination schedule
  • Written informed consent prior to surgery

Exclusion Criteria:

  • Previous ocular surgery or trauma
  • Extreme shallow anterior chamber
  • Uncontrolled systemic or ocular disease
  • Associated corneal pathologies (e.g., edema, scarring) or relevant other ophthalmic diseases that may result in altered visual outcome or lens stability (e.g., pseudoexfoliation syndrome, floppy iris syndrome, glaucoma, retinal disease)
  • Concurrent participation in another clinical investigation
  • Pregnancy or lactation (pregnancy test will be performed in women of reproductive age)

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Intervensjonsmodell: Enkeltgruppeoppdrag
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: Acunex Vario toric

Patient will recieve the Acunex Vario IOL during cataract surgery

The Acunex Vario toric IOL, toric EDOF IOL, will be implanted

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
IOL axis rotation
Tidsramme: 12 monthes

The IOL axis rotation before and after cataract surgery will be analyzed with retroillumination photographs

12 monthes

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Distance visual acuity
Tidsramme: 12 months

Uncorrected and corrected distance visual acuity before and after cataract surgery will be determined using ETDRS-charts in a distance of 4 metres

12 months
Intermediate visual acuity
Tidsramme: 12 months

Uncorrected and corrected intermediate visual acuity before and after cataract surgery will be determined using ETDRS-charts in a distance of 66 centimetres

12 months
Refraction
Tidsramme: 12 months

Refraction before and after cataract surgery will be determined using trial frame glasses and Jackson cross cylinders

12 months

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Sponsor

Etterforskere

  • Hovedetterforsker: Oliver Findl, Prim. Prof. Dr., Vienna Institute for Research in Ocular Surgery

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

27. mars 2026

Primær fullføring (Antatt)

1. desember 2027

Studiet fullført (Antatt)

1. juli 2028

Datoer for studieregistrering

Først innsendt

3. november 2026

Først innsendt som oppfylte QC-kriteriene

3. november 2026

Først lagt ut (Faktiske)

9. november 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

9. november 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

3. november 2026

Sist bekreftet

1. november 2026

Mer informasjon

Begreper knyttet til denne studien

Ytterligere relevante MeSH-vilkår

Andre studie-ID-numre

  • Acunex Vario toric

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

UBESLUTTE

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .