- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT06548113
Imagerie Sensorielle Synchronisée et Neuromodulation
Enquête sur l'imagerie cérébrale sensorielle synchronisée et la neuromodulation
The purpose of this research study is to better understand the relationship between the type of brain stimulation used and how it changes brain activity in adult military Veterans. The goal is to use this understanding to develop new, personalized brain stimulation. The investigators evaluate brain changes from different types of transcranial magnetic brain stimulation (TMS).
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Jessica M Ross, PhD
- Numéro de téléphone: (530) 902-2450
- E-mail: jessica.ross1@va.gov
Lieux d'étude
-
-
California
-
Palo Alto, California, États-Unis, 94304-1207
- VA Palo Alto Health Care System, Palo Alto, CA
-
Contact:
- Jessica M Ross, PhD
- Numéro de téléphone: (530) 902-2450
- E-mail: jessica.ross1@va.gov
-
Chercheur principal:
- Jessica M Ross, PhD
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Men and women
- English speaking
- Military Veterans
Exclusion Criteria:
- Those with a contraindication for magnetic resonance imaging (MRIs), e.g. implanted metal
- History of head trauma with loss of consciousness
- History of seizures or on medications that substantially reduce seizure threshold
- Neurological or uncontrolled medical disease
- Active substance abuse
- Currently pregnant or breastfeeding
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Science basique
- Répartition: Randomisé
- Modèle interventionnel: Affectation croisée
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: Standard TMS
A series of standard TMS protocols will be delivered to determine target engagement compared to seTMS. TMS will be delivered using neuro-navigation based on participant's own MRI images. Intensity will be set to 120% of the participant's motor threshold. Participants will be monitored during the session for adverse events and/or side effects. |
transcranial magnetic brain stimulation |
|
Comparateur actif: Sensory-entrained TMS (seTMS)
Sensory entrained TMS (seTMS) is a combination of music and TMS to align brain oscillations and enhance the effects of TMS. seTMS will be delivered to determine target engagement to noninvasive seTMS brain stimulation compared to standard TMS. TMS will be delivered using neuro-navigation based on participant's own MRI images. Intensity will be set to 120% of the participant's motor threshold. Participants will be monitored during the session for adverse events and/or side effects. |
transcranial magnetic brain stimulation |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Transcranial Magnetic Stimulation (TMS) / Electroencephalography (EEG) change
Délai: 45 minutes
|
Change in the TMS-EEG measure will be assessed before, during, and after each TMS session. Specifically, the difference in size of the evoked response after a single TMS pulse in the frontoparietal region will be quantified in microVolts and compared between standard TMS and sensory-entrained TMS (se-TMS). |
45 minutes
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Jessica M Ross, PhD, VA Palo Alto Health Care System, Palo Alto, CA
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- MHBC-011-24F
- 76106 (Autre subvention/numéro de financement: VA Palo Alto Health Care System)
- 1IK2CX002812-01A2 (Subvention/contrat des NIH des États-Unis)
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .