- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT06677424
Base de données d'intervalles de référence NeuroCatch (RR)
Distributions empiriques des composants ERP obtenues par la plateforme NeuroCatch® 2 : développement d'une base de données d'intervalles de référence
The purpose of this study is to understand how the brain responds to sounds and words, and how this response varies between individuals. The purpose if this study is to develop data set comparing the results from one individual with those from other members (a reference interval database of NeuroCatch® Platform 2) and to quantify the expected distribution across sex and age. NeuroCatch® Platform 2, is a medical device approved by Health Canada. The plan is to enroll 810 participants, the study includes screening for eligibility and one brain scan. The study is conducted at the Centre for Neurology Studies in Surrey, BC or at its satellite sites ( if required).
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Study specific Procedures: Includes a screen for eligibility and a scan visit. The total time 30 minutes to 1 hour for the whole study. The procedures can be completed on the same day or split between two days.
Screening visit (15- 30min, virtual visit): Prior to any procedures being conducted, Informed Consent Form will be reviewed in detail, an opportunity will be given to decide to participate in the study or not and if all the study requirements are met as well as all the questions have been answered, consent form is signed. Participant study eligibility is reviewed including medical history, and brain scan requirements. If participant is eligible, scan visit will be completed. If participant is not eligible no further study procedures will be completed.
Scan visit (15-30 min at the clinic): During the scan visit demographic information ( date of birth, sex, level of education, recent sleep, self-described mood, caffeine intake, alcohol consumption, nicotine usage, psychoactive usage, handedness, first language, profession and current medications) is collected, brain scan safety questionnaire is completed and a brain scan with NeuroCatch® Platform 2 will be completed.
NeuroCatch scan procedure: A cap with the EEG sensors is placed on your scalp and will be adjusted to get good recordings of brain activity. An alcohol pad is used to clean the skin of your forehead, and a plastic syringe tip or wooden dowel to move your hair out of the way to place the EEG sensors/electrodes. A small amount of a conductive gel is applied under each electrode. This takes between 5-20 minutes. Once its all set up, you will be asked to listen to an auditory sequence that is 6 minutes long. During this period, you are asked to sit still and listen to the sounds and the words.
Any information about you obtained from or for this research study will be kept as confidential as possible, All participants will be assigned a participant ID and data will identified using the ID.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
British Columbia
-
Surrey, British Columbia, Canada, V3V 0E8
- Centre for Neurology Studies, 13761 96 Ave, Unit 1004
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
INCLUSION CRITERIA
- Any sex, at least 6 years of age or older
- Able to understand the informed consent/assent form (in English), study procedures and willing to participate in study; participants under 19 must also have a parent/guardian who is able to understand and provide informed consent on their behalf.
- Able to remain seated and focused for 7 minutes
- In good health with no history of clinically relevant neurological illness or injury
EXCLUSION CRITERIA
- Requires the use of hearing aids or a cochlear implant, diagnosed with tinnitus that is currently active, or has temporary damage to hearing (e.g., punctured ear drum). Or unable to detect a 740Hz tone played at 85dB in both ears.
- Implanted pacemaker or other electrical stimulator(s)
- Metal or plastic implants in the skull, excluding dental/facial implants.
- Not native-level in English
- Previous exposure to the NeuroCatch® Platform 2 audio sequences in the last 3 months
- History of clinically relevant neurological disorders or injury (e.g., epilepsy, Parkinson's disease, traumatic brain injury, etc.)
- History of chronic pain or chronic headache disorders (e.g. migraine, tension headaches, fibromyalgia, etc.)
- Currently diagnosed with any sleeping disorders (e.g. sleep apnea, hypersomnia, insomnia, parasomnia, etc.)
- Diagnosed with any memory disorders.
- History of clinically relevant major psychiatric disorders (e.g., schizophrenia, bipolar disorder, etc.)
- History of alcohol or substance misuse that, in the opinion of the Investigator, may impact brain function
- Use of medications that affect brain function (e.g., antiepileptic drugs, antipsychotics, stimulants, etc.)
- Serious medical conditions affecting brain functions (e.g., stroke, brain tumor, neurodegenerative diseases, etc.)
- Undergoing chemotherapy or any form of intensive long-term therapy that, in the opinion of the Investigator, may impact brain function.
- Unhealthy scalp (e.g., apparent open wounds and/or bruised or weakened skin)
- Allergy to EEG gel
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Autre
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: NeuroCatch® Platform 2
NeuroCatch® Platform 2 Software enables EEG data collection by recording the data during an audio stimulus presentation (i.e., the NeuroCatch® Scan). The Software plays a 6-min proprietary audio sequence stimulus. The NeuroCatch® software generates unique, randomized audio sequences specifically designed to elicit specific brain responses. Once a NeuroCatch® Scan is complete, the software automatically processes the raw EEG data to generate 6 ERP results and saves the results, the data, and details about the scan to the secure NeuroCatch® server in the cloud. While EEG is only collected during the scan, the participant is exposed to the device from the time the cap is placed on the head until it is taken off. During the scan, the participant will listen to an auditory stimulus sequence consisting of tones and words. This has been designed and limited to safe audio levels. |
The NeuroCatch® Platform 2, a medical device system developed by NeuroCatch Inc., consists of software and hardware that captures brain health information. The platform intends to provide a quick, portable and easy to use solution for the acquisition, display, analysis, storage, reporting and management of electroencephalograph (EEG) and event-related potential (ERP; brain response to a stimulus) information. The device is approved as a medical device by Health Canada. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Amplitude & Latency collection for NeuroCatch® Platform 2
Délai: 20 minutes
|
Response size (amplitude in microvolts) and response timing (latency in milliseconds) will be collected for the ERPs N100, P300 and N400. |
20 minutes
|
|
Demographic indicators
Délai: 5 minutes
|
Demographic indicators to be collected such as year of birth, sex, level of education. |
5 minutes
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Assessing Influences on Brain Function: NeuroCatch® to Lifestyle and Health Factors
Délai: 5 minutes
|
Measurements include: current medications, mood, total sleep hours, caffeine and alcohol intake, nicotine and psychoactive substance use, as well as any medications taken within 24 hours before the scan, noting whether each is more, less, or equal to the participant's typical amount. |
5 minutes
|
Autres mesures de résultats
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Safety assessments
Délai: 30 minutes
|
Safety assessments will me assessed by subjective report of incidence and severity of adverse events. |
30 minutes
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Jan Venter, MD, Centre for Neurology Studies
Publications et liens utiles
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- NCI_NCClin_007
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .