Studio di follow-up clinico post-commercializzazione del sistema valvolare aortico transcatetere VitaFlow Liberty™

This is a prospective, single-arm, multi-center, observational, post-market clinical investigation to document the clinical safety and performance of MicroPort CardioFlow VitaFlow Liberty™ Transcatheter Aortic Valve System in the routine practice for the treatment of severe aortic valve stenosis. The primary endpoint is the composite rate of all-cause mortality and stroke with disability at 12 months.

Patients will receive transcatheter aortic valve replacement and examinations at the screening, procedure, discharge, and follow-up per local standard of care.

Panoramica dello studio

Stato

Reclutamento

Condizioni

Intervento / Trattamento

Tipo di studio

Osservativo

Iscrizione (Stimato)

222

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

      • Galway, Irlanda
        • Reclutamento
        • Galway University Hospital
        • Contatto:
          • Darren Mylotte, MD
      • Castel Volturno, Italia
        • Reclutamento
        • Pineta Grande Hospital
        • Contatto:
      • Pisa, Italia
        • Reclutamento
        • Ospedale Cisanello
        • Contatto:
      • Potenza, Italia
        • Reclutamento
        • Azienda Ospedaliera Regionale -S.Carlo
        • Contatto:
      • Carnaxide, Portogallo
        • Reclutamento
        • Hospital de Santa Cruz
        • Contatto:
      • A Coruña, Spagna
        • Reclutamento
        • Hospital Universitario de a Coruna
        • Contatto:
      • Madrid, Spagna
      • Valladolid, Spagna
      • Lucerne, Svizzera
        • Reclutamento
        • Luzerner Kantonsspital | Herzzentrum
        • Contatto:
          • Dr.Stefan Toggweiler
          • Numero di telefono: 0412051111
          • Email: ifo@luks.ch

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Patients with symptomatic, severe calcified aortic stenosis who are at high surgical risk.

Descrizione

Inclusion Criteria:

  1. Subjects of age≥ 18 years
  2. Subjects with severe, symptomatic, calcific aortic stenosis who are considered at high risk for surgical aortic valve replacement (AVR).
  3. Subject can understand the purpose of the clinical investigation, has signed voluntarily the informed consent form and is agreeing to the scheduled follow up requirements.

Exclusion Criteria:

  1. Pre-existing mechanical heart valve in aortic position
  2. A known hypersensitivity or contraindication to all anticoagulation /antiplatelet regimens (or inability to be anticoagulated for the index procedure), to nickel or titanium, to nitinol, to dairy products, to polyethylene terephthalate (PET) or contrast media
  3. Ongoing sepsis, including active endocarditis
  4. Anatomically not suitable for the VitaFlow Liberty TAV system
  5. LVEF<20%
  6. Estimated life expectancy of less than 12 months
  7. Any medical, social or psychological condition that in the opinion of the Heart Team precludes the subject from receiving transcatheter aortic valve replacement
  8. Currently participating in another drug or device trial (excluding registries) for which the primary endpoint has not been assessed
  9. Inability to comply with the clinical investigation follow-up or other clinical investigation requirements
  10. Patients temporally unable to provide written informed consent (e. g. unconscious emergency patients)

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Modelli osservazionali: COHORT
  • Prospettive temporali: PROSPECTIVE

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
Indagine clinica a braccio singolo

Transcatheter Aortic Valve Replacement with VitaFlow Liberty™ Transcatheter Aortic Valve System.

Patients will receive transcatheter aortic valve replacement and examinations at the screening, procedure, discharge, and follow-up per local standard of care.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Composite rate of all-cause mortality and stroke with disability
Lasso di tempo: 12 months post procedure

Composite rate of all-cause mortality and stroke with disability

12 months post procedure

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Safety outcomes defined by VARC3
Lasso di tempo: 30 days, 12 months, and 2-5 years post procedure

Rate of all-cause mortality, myocardial infarction, stroke, implanted related new and/or worsen conduction disturbances and arrhythmias, new permanent pacemaker implantation, procedure-related or valve-related hospitalization defined by VARC 3.

30 days, 12 months, and 2-5 years post procedure
Safety outcomes defined by VARC3
Lasso di tempo: 30 days and 12 months post procedure

Rate of type 2-4 bleeding, major vascular and access-related complications, acute kidney injury (stage 2-4) defined by VARC 3

30 days and 12 months post procedure
Safety outcomes defined by VARC3
Lasso di tempo: acute procedure (within 24 hours)

Rate of other acute procedural and technical valve related complications: conversion to surgery; unplanned use of mechanical circulatory support; implantation of multiple (>1) transcatheter valves during the index hospitalization; valve mal-position

acute procedure (within 24 hours)
Device success
Lasso di tempo: 30 days post implantation

Device success defined by VARC 3

30 days post implantation
Device early safety
Lasso di tempo: 30 days post implantation

Device early safety defined by VARC 3

30 days post implantation
Bioprosthesis haemodynamic function
Lasso di tempo: Discharge (24 hours to 7 days), 30 days,12 months and 2-5 years post implantation

Bioprosthesis haemodynamic function (assessed by echocardiography) including effective orifice area (cm2).

Discharge (24 hours to 7 days), 30 days,12 months and 2-5 years post implantation
Bioprosthesis haemodynamic function
Lasso di tempo: Discharge (24 hours to 7 days), 30 days,12 months and 2-5 years post implantation

Bioprosthesis haemodynamic function (assessed by echocardiography) including mean transvalvular gradient (mmHg).

Discharge (24 hours to 7 days), 30 days,12 months and 2-5 years post implantation
Bioprosthesis haemodynamic function
Lasso di tempo: Discharge (24 hours to 7 days), 30 days,12 months and 2-5 years post implantation

Bioprosthesis haemodynamic function (assessed by echocardiography) including aortic regurgitation (paravalvular, central and total).

Discharge (24 hours to 7 days), 30 days,12 months and 2-5 years post implantation
Bioprosthetic valve dysfunction
Lasso di tempo: 12 months and 2-5 years post procedure

Moderate or severe haemodynamic valve deterioration defined by VARC3

12 months and 2-5 years post procedure
Bioprosthetic valve dysfunction
Lasso di tempo: 12 months and 2-5 years post procedure

Bioprosthetic valve failure defined by VARC3

12 months and 2-5 years post procedure
Bioprosthetic valve dysfunction
Lasso di tempo: 12 months and 2-5 years post procedure

Clinically significant valve thrombosis defined by VARC3

12 months and 2-5 years post procedure
NYHA Classification
Lasso di tempo: From baseline to discharge (24 hours to 7 days), 30 days, 12 months and 2-5 years post procedure

Changes in cardiac function at discharge, 30 days and 12 months and 2-5 years post implantation according to the NYHA Classification Scheme compared to baseline

From baseline to discharge (24 hours to 7 days), 30 days, 12 months and 2-5 years post procedure
Rate of Alwide Plus Balloon Catheter pre-dilation success
Lasso di tempo: During procedure

Defined as successful access, delivery and dilation the aortic valve, and retrieval for the AlwideTM Plus balloon catheter

During procedure
Alwide Plus Balloon Catheter related adverse-event
Lasso di tempo: Discharge
Discharge
Predictors for the permanent pacemaker implantation
Lasso di tempo: Baseline or intraprocedure

Including but not limited to pre-existing conduction disturbance, implant depth, LVOT calcium volume , post-dilatation

Baseline or intraprocedure

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Investigatore principale: Darren Mylotte, MD, Galway University Hospital

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

6 maggio 2025

Completamento primario (Stimato)

6 giugno 2028

Completamento dello studio (Stimato)

1 giugno 2033

Date di iscrizione allo studio

Primo inviato

21 luglio 2024

Primo inviato che soddisfa i criteri di controllo qualità

30 luglio 2024

Primo Inserito (Effettivo)

2 agosto 2024

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

1 ottobre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

28 settembre 2026

Ultimo verificato

1 dicembre 2025

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • VitaFlow EU-2024

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .