Iatrogenic Atrial Septal Defect Gradient for Intraprocedural Success After M-teer (IASIS)
Iatrogenic ASD Gradient as a Marker of Residual Mitral Regurgitation Severity After M-TEER Procedure
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Athens, Grecia, 11521
- First Cardiology Department, Hippokration General Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy
- patients undergoing M-TEER as a bridge to heart transplantation
Exclusion Criteria:
- Patients with post-procedural transmitral gradient ≥5 mmHg,
- Patients with right-to-left shunt requiring iASD closure,
- Patients, who decline to provide written informed consent.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Altro: M-TEER patients
high- or prohibitive-surgical-risk patients with severe mitral regurgitation
|
Hemodynamic and echocardiographic assessment of M-TEER procedural success
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER
Lasso di tempo: The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
|
|
the cut-off point of iASD gradient for identifying mild or trivial mitral regurgitation after M-TEER procedure
Lasso di tempo: 4 years
|
To determine the cut-off point of the post-procedural iASD gradient for identifying mild or trivial residual mitral regurgitation after M-TEER procedure
|
4 years
|
Collaboratori e investigatori
Sponsor
Sponsor
Pubblicazioni e link utili
Pubblicazioni generali
- Sakul S, DiazSaravia S, Berman B, Dominguez AC, Lerakis S, Argulian E. "Echo-derived estimate of peak left atrial pressure in patients with iatrogenic atrial septal defects following transcatheter mitral edge-to-edge repair". Int J Cardiol. 2026 Feb 1;444:133975. doi: 10.1016/j.ijcard.2025.133975. Epub 2025 Oct 25.
- Zoghbi WA, Asch FM, Bruce C, Gillam LD, Grayburn PA, Hahn RT, Inglessis I, Islam AM, Lerakis S, Little SH, Siegel RJ, Skubas N, Slesnick TC, Stewart WJ, Thavendiranathan P, Weissman NJ, Yasukochi S, Zimmerman KG. Guidelines for the Evaluation of Valvular Regurgitation After Percutaneous Valve Repair or Replacement: A Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Angiography and Interventions, Japanese Society of Echocardiography, and Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr. 2019 Apr;32(4):431-475. doi: 10.1016/j.echo.2019.01.003. Epub 2019 Feb 20. No abstract available.
- Little SH, Quader N, Brady M, Dillenbeck A, Garcia-Sayan E, Jain R, Mackensen GB, Price MJ, Saric M, Scalia GM, Wang DD, Hahn RT. Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2026 Jun;39(6):529-550. doi: 10.1016/j.echo.2026.03.003.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 22532/19-12-2023
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .