Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Surface Topography and Radiographic Spinal Damage in Radiographic Axial Spondyloarthritis

10 novembre 2026 aggiornato da: Seyma Alkan, Ankara Etlik City Hospital

Association Between Static Spinal Posture Assessed by Surface Topography (DIERS) and Radiographic Structural Damage (Modified Stoke Ankylosing Spondylitis Spine Score, mSASSS) in Radiographic Axial Spondyloarthritis: A Cross-Sectional Study

Radiographic axial spondyloarthritis (r-axSpA) causes progressive structural damage of the spine, conventionally quantified on lateral cervical and lumbar radiographs using the modified Stoke Ankylosing Spondylitis Spine Score (mSASSS). Repeated radiography entails cumulative radiation exposure, substantial inter-reader variability and low sensitivity in early disease. DIERS Formetric 4D (four-dimensional) surface topography (DIERS International GmbH, Schlangenbad, Germany) provides radiation-free three-dimensional modelling of the spine and pelvis. The association between sagittal balance and structural damage has been demonstrated with a radiation-based biplanar low-dose radiography system (EOS imaging, Paris, France), but whether a radiation-free topographic method reflects the same association has not been investigated.

This single-centre, cross-sectional observational study will enrol 53 adults with r-axSpA fulfilling the Assessment of SpondyloArthritis international Society (ASAS) criteria with radiographic sacroiliitis according to the modified New York criteria. At a single study visit, static DIERS Formetric 4D measurements, chest expansion, the Bath Ankylosing Spondylitis Metrology Index (BASMI), the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), the Bath Ankylosing Spondylitis Functional Index (BASFI) and the Ankylosing Spondylitis Disease Activity Score with C-reactive protein (ASDAS-CRP) are obtained. mSASSS is scored by a single reader, blinded to clinical and topographic data, on existing lateral cervical and lumbar radiographs obtained within the preceding 12 months; no additional radiographs are performed for the study. The primary analysis is the correlation between total mSASSS and the DIERS flèche cervicale (cervical sagittal anterior displacement).

Panoramica dello studio

Stato

Reclutamento

Condizioni

Intervento / Trattamento

Descrizione dettagliata

Design: single-centre, cross-sectional, non-interventional correlation study in a single patient group; no control group. All participant data are collected in one assessment session lasting approximately 45 to 60 minutes.

Measurements: (a) demographic and anthropometric data; (b) disease duration, age at symptom onset, comorbidities, extra-articular involvement (uveitis, inflammatory bowel disease, psoriasis), human leukocyte antigen B27 (HLA-B27) status, current medication category; (c) radiographic sacroiliitis grade according to the modified New York criteria and the modified Stoke Ankylosing Spondylitis Spine Score (mSASSS; range 0 to 72), scored by a single reader blinded to clinical and topographic data; (d) chest expansion; (e) the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), the Bath Ankylosing Spondylitis Functional Index (BASFI) and the Ankylosing Spondylitis Disease Activity Score with C-reactive protein (ASDAS-CRP), the latter using routine C-reactive protein values with no additional blood sampling; (f) Bath Ankylosing Spondylitis Metrology Index (BASMI) total score and its five components; (g) DIERS Formetric 4D (four-dimensional) static parameters: flèche cervicale (cervical sagittal anterior displacement, mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Statistical analysis: distribution is assessed with the Shapiro-Wilk test. The primary analysis is a Pearson or Spearman correlation between total mSASSS and flèche cervicale, reported with effect size and 95% confidence interval, followed by multiple linear regression adjusted for age and disease duration. Secondary analyses comprise correlations of DIERS parameters with clinical indices and an exploratory receiver operating characteristic analysis of the ability of DIERS sagittal parameters to predict mSASSS thresholds. The Benjamini-Hochberg procedure is applied to correct for multiple comparisons. Significance is set at p<0.05. Analyses are performed with IBM SPSS Statistics (Statistical Package for the Social Sciences) version 23 or later.

Sample size: calculated with G*Power 3.1.9 for a bivariate normal correlation model, two-tailed, correlation under the null hypothesis (rho H0) = 0, expected effect size r = 0.40, alpha = 0.05 and power = 0.85, giving a required sample of 53 participants (actual power 0.857). The effect size was set conservatively at r = 0.40 rather than the r = 0.61 reported by Wanders et al. (2005) for occiput-to-wall distance versus mSASSS, because DIERS parameters are not identical to clinical mobility measures.

Reporting follows the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement.

Tipo di studio

Osservativo

Iscrizione (Stimato)

53

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

    • Yenimahalle
      • Ankara, Yenimahalle, Turchia (Türkiye), 06560
        • Reclutamento
        • Ankara Etlik City Hospital, Department of Physical Medicine and Rehabilitation
        • Contatto:
          • Seyma Alkan, Medical Doctor
          • Numero di telefono: +90 5383379791
          • Email: symalkan@gmail.com

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 65 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Consecutive patients with radiographic axial spondyloarthritis attending the spondyloarthritis outpatient clinic of the Department of Physical Medicine and Rehabilitation, Ankara Etlik City Hospital.

Descrizione

Inclusion Criteria:

  • Age 18 to 65 years
  • Diagnosis of radiographic axial spondyloarthritis fulfilling the Assessment of SpondyloArthritis international Society (ASAS) criteria, confirmed by radiographic sacroiliitis according to the modified New York criteria
  • Able to provide written informed consent and to complete the assessments
  • Available lateral cervical and lumbar radiographs obtained within the 12 months preceding the DIERS measurement

Exclusion Criteria:

  • Neurological disease affecting balance, posture or gait (for example Parkinson disease, amyotrophic lateral sclerosis, cerebellar or vestibular disorders, history of stroke)
  • History of lower extremity joint arthroplasty (hip or knee)
  • Orthopaedic conditions affecting posture, balance or gait (ununited fracture, previous spinal or lower extremity surgery)
  • Advanced cardiopulmonary disease, active infection or malignancy
  • Pregnancy

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Modelli osservazionali: CASE_ONLY
  • Prospettive temporali: CROSS_SECTIONAL

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
Radiographic axial spondyloarthritis patients

Adults aged 18 to 65 years with radiographic axial spondyloarthritis fulfilling the Assessment of SpondyloArthritis international Society (ASAS) classification criteria with radiographic sacroiliitis according to the modified New York criteria, attending the spondyloarthritis outpatient clinic. All participants undergo a single assessment session including static DIERS Formetric 4D surface topography, chest expansion and clinical indices: Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Bath Ankylosing Spondylitis Functional Index (BASFI), Bath Ankylosing Spondylitis Metrology Index (BASMI) and Ankylosing Spondylitis Disease Activity Score with C-reactive protein (ASDAS-CRP). The modified Stoke Ankylosing Spondylitis Spine Score (mSASSS) is scored on existing lateral cervical and lumbar radiographs obtained within the preceding 12 months; no additional radiographs are taken.

Radiation-free three-dimensional assessment of spinal and pelvic surface topography performed once in standing position. No radiation, no contact, no intervention on treatment.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Correlation between total mSASSS and DIERS fleche cervicale
Lasso di tempo: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Total modified Stoke Ankylosing Spondylitis Spine Score (mSASSS; range 0 to 72, higher scores indicate greater structural damage), correlated with flèche cervicale (cervical sagittal anterior displacement, mm) measured by DIERS Formetric 4D surface topography. Reported as a correlation coefficient with magnitude, direction and 95% confidence interval.

Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Correlation between DIERS sagittal parameters and BASMI
Lasso di tempo: Single assessment session (Day 1)

Bath Ankylosing Spondylitis Metrology Index (range 0 to 10, higher scores indicate worse spinal mobility) correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Correlation between DIERS sagittal parameters and ASDAS-CRP
Lasso di tempo: Single assessment session (Day 1)

Ankylosing Spondylitis Disease Activity Score with C-reactive protein (higher scores indicate greater disease activity) correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Correlation between total mSASSS and other DIERS Formetric static parameters
Lasso di tempo: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Total modified Stoke Ankylosing Spondylitis Spine Score (mSASSS; range 0 to 72, higher scores indicate greater structural damage) correlated with the remaining DIERS Formetric 4D static parameters: sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical depth distance (mm), lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees). Reported as correlation coefficients with 95% confidence intervals.

Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment
Correlation between DIERS sagittal parameters and BASDAI
Lasso di tempo: Single assessment session (Day 1)

Bath Ankylosing Spondylitis Disease Activity Index (range 0 to 10, higher scores indicate greater disease activity) correlated with DIERS Formetric 4D static parameters: flèche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Correlation between DIERS sagittal parameters and BASFI
Lasso di tempo: Single assessment session (Day 1)

Bath Ankylosing Spondylitis Functional Index (range 0 to 10, higher scores indicate worse physical function) correlated with DIERS Formetric 4D static parameters: flèche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Correlation between DIERS sagittal parameters and chest expansion
Lasso di tempo: Single assessment session (Day 1)

Chest expansion measured in centimetres correlated with DIERS Formetric 4D static parameters: flèche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Discriminative performance of DIERS sagittal parameters for mSASSS thresholds
Lasso di tempo: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Exploratory receiver operating characteristic analysis of DIERS Formetric 4D sagittal parameters for discriminating total modified Stoke Ankylosing Spondylitis Spine Score (mSASSS) thresholds. Reported as area under the curve with 95% confidence interval, sensitivity and specificity.

Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Investigatore principale: Ajda Bal, Professor of Physical Medicine and Rehabilitation

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

19 settembre 2026

Completamento primario (Stimato)

20 giugno 2027

Completamento dello studio (Stimato)

20 giugno 2027

Date di iscrizione allo studio

Primo inviato

28 settembre 2026

Primo inviato che soddisfa i criteri di controllo qualità

28 settembre 2026

Primo Inserito (Effettivo)

2 ottobre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

12 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

10 novembre 2026

Ultimo verificato

1 novembre 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • AEŞH-BADEK1-2026-909

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Descrizione del piano IPD

Individual participant data will not be shared. According to the study protocol, research data are accessible only to the investigators. Aggregate results will be published.

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .