Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Rotator Cuff Repair Using Standard Double Row Technique With Platelet Rich Fibrin Membrane vs. Standard Double Row Technique (RCRPRFM)

11 luglio 2017 aggiornato da: HealthPartners Institute

Arthroscopic Rotator Cuff Repair Using Standard Double Row Technique With Platelet Rich Fibrin Membrane vs. Standard Double Row Technique: A Randomized Blinded Outcomes Study

This study is a single-blind, randomized study evaluating the 6 month and 2 year outcomes of patients treated with arthroscopic rotator cuff repair using one of two techniques. One technique used is the standard double row repairs utilizing medial and laterally based anchor fixation and the other technique is the standard double row repairs utilizing medial and laterally based anchor fixation with the use of plateley rich fibrin membrane (PRFM). It is hypothesized that patients undergoing the surgery with the PRFM will report a higher quality of life than the patients that do not receive this treatment.

Panoramica dello studio

Stato

Completato

Tipo di studio

Interventistico

Iscrizione (Effettivo)

97

Fase

  • Fase 4

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Minnesota
      • Bloomington, Minnesota, Stati Uniti, 55431
        • TRIA Orthopaedic Center

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Evidence of a rotator cuff tear as determined by clinical examination and diagnostic imaging (MRI)
  • Patient undergoes arthroscopic rotator cuff repair
  • Age 18 or older

Exclusion Criteria:

Pre-operative exclusion criteria

  • Patient has had a previous arthroscopic rotator cut repair
  • A previous diagnosis of Rheumatoid Arthritis
  • Evidence of major joint trauma, infection, avascular necrosis, chronic dislocation, inflammatory or degenerative glenohumeral arthropathy, frozen shoulder, or previous surgery of the affected shoulder,
  • Evidence of significant rotator cuff arthropathy with superior humeral translation and acromial erosion diagnosed by x-ray or other investigations,
  • Medical device that would exclude the patient from having a MRI, including a pacemaker, cardiac defibrillator, aneurysm clips, carotid artery clamp, neurostimulator, insulin or infusion pump, implanted drug infusion device, bone growth/fusion stimulator, or ear implant.
  • Major medical illness (life expectancy less then 2 years or unacceptably high operative risk),
  • Inability to speak or read English
  • Psychiatric illness that precludes informed consent.
  • Pregnant patients.
  • Age 17 or younger
  • Unwillingness to be followed for 2 years.
  • Bilateral Rotator cuff tear confirmed by clinical exam and MRI
  • Patients enrolled in the study who demonstrate retear on clinical exam and MRI, then elect for a repeat surgery.

Intra-operative exclusion criteria (Note: This information will be collected during the chart audit and patients will be excluded from the study at that time.)

  • Irreparable cuff tears or tears extending into the subscapularis or teres minor
  • Isolated teres minor or subscapularis tears.
  • Inelastic and immobile tendon which cannot be advanced to articular margin

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Separare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Double Row
Sperimentale: Double Row with PRFM

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Return to Function
Lasso di tempo: Baseline
The Western Ontario Rotator Cuff Index total score is on a scale of 0-2100; where 0 is the best score and 2100 is the score. There is a discrepancy between overall number of participants analyzed for this measure when compared to the participant flow module. More patients completed a baseline measure than those that completed the entire study.
Baseline
Return to Function
Lasso di tempo: 6 months
The Western Ontario Rotator Cuff Index total score is on a scale of 0-2100; where 0 is the best score and 2100 is the score. There is a discrepancy between overall number of participants analyzed for this measure when compared to the participant flow module. More patients completed a baseline measure than those that completed the entire study.
6 months
Return to Function
Lasso di tempo: 24 months
Western Ontario Rotator Cuff Index
24 months

Altre misure di risultato

Misura del risultato
Misura Descrizione
Lasso di tempo
Spraspinatus Strength Measurements
Lasso di tempo: Baseline
Strength of supraspinatus in newton meters with a hand held dynomometer. Three trials were recorded and an average taken. Data is reported as measured by % of uninvolved. Average of strength measures for involved/average of strength measures for uninvolved x 100.
Baseline
MRI
Lasso di tempo: 6 months

MRI was used to determine size of the defect in the proximal to distal, humeral to bursal, superior to inferior direction in all four tendons. All post operative rotator cuffs were described using the MRI rating system of Sugaya. This classification distinguishes 5 outcomes of rotator cuff repair based on integrity of the tendon determine by post operative MRI. Type I demonstrates the repaired rotator cuff has sufficient thickness and homogeneously low intensity on each image; Type II sufficient thickness with a partial high intensity area; Type III insufficient thickness without discontinuity, Type IV the presence of a minor discontinuity in more than one slice of each image suggestive of small tear; Type V the presence of a major discontinuity on each image suggestive of a large tear.

Higher grades are worse radiographic outcomes.

6 months
Supraspinatus Strength Measurements
Lasso di tempo: 6 months
Strength of supraspinatus in newton meters with a hand held dynomometer. Three trials were recorded and an average taken. Data is reported as measured by % of uninvolved. Average of strength measures for involved/average of strength measures for uninvolved x 100.
6 months
Supraspinatus Strength Measurements
Lasso di tempo: 24 months
Strength of supraspinatus in newton meters with a hand held dynomometer. Three trials were recorded and an average taken. Data is reported as measured by % of uninvolved. Average of strength measures for involved/average of strength measures for uninvolved x 100.
24 months
Infraspinatus Strength Measurements
Lasso di tempo: Baseline
Strength of infraspinatus in newton meters with a hand held dynomometer. Three trials were recorded and an average taken. Data is reported as measured by % of uninvolved. Average of strength measures for involved/average of strength measures for uninvolved x 100.
Baseline
Infraspinatus Strength Measurements
Lasso di tempo: 6 months
Strength of infraspinatus in newton meters with a hand held dynomometer. Three trials were recorded and an average taken. Data is reported as measured by % of uninvolved. Average of strength measures for involved/average of strength measures for uninvolved x 100.
6 months
Infraspinatus Strength Measurements
Lasso di tempo: 24 months
Strength of infraspinatus in newton meters with a hand held dynomometer. Three trials were recorded and an average taken. Data is reported as measured by % of uninvolved. Average of strength measures for involved/average of strength measures for uninvolved x 100.
24 months

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

1 luglio 2011

Completamento primario (Effettivo)

1 dicembre 2015

Completamento dello studio (Effettivo)

1 dicembre 2015

Date di iscrizione allo studio

Primo inviato

4 agosto 2014

Primo inviato che soddisfa i criteri di controllo qualità

3 ottobre 2014

Primo Inserito (Stima)

6 ottobre 2014

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

9 agosto 2017

Ultimo aggiornamento inviato che soddisfa i criteri QC

11 luglio 2017

Ultimo verificato

1 ottobre 2015

Maggiori informazioni

Termini relativi a questo studio

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Strappo della cuffia dei rotatori

Prove cliniche su Double Row

Sottoscrivi