DWI senza contrasto per lo screening supplementare
DWI senza contrasto per lo screening supplementare delle donne con seni densi
Diffusion-weighted imaging (DWI) is a short (under 5 minutes) non-contrast MRI technique that has shown promise for the detection and characterization of breast cancer. Our preliminary data has shown that DWI holds potential for detecting mammographically and clinically-occult breast cancers. However, current technical limitations reduce the sensitivity of DWI for screening applications.
The identification of a screening tool to complement mammography that is more accurate than ultrasound and faster, less expensive, and safer than conventional contrast-enhanced MRI would have significant clinical impact by improving the early detection of cancer in women with dense breasts. We hypothesize that an optimized DWI approach will enable detection of mammographically occult breast cancer in women with dense breasts with high sensitivity and low false positive rate.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Hypothesis: With technical optimizations, non-contrast DWI can detect clinically and mammographically occult breast cancer in women with dense breasts with high sensitivity and low false positive rate.
Aim 1: Improve the breast DWI technique to maximize spatial resolution, reduce distortion, and increase lesion contrast.
- Develop novel DWI acquisition to increase spatial resolution and reduce distortion (using reduced field of-view and/or multishot echo planar imaging techniques)
- Identify optimal diffusion sensitization (b-value) to maximize conspicuity of cancers in women with dense breasts
Aim 2: Develop interpretation tools to optimize diagnostic performance for detecting cancer on DWI.
- Determine quantitative DWI thresholds (contrast-to-noise ratio, apparent diffusion coefficient [ADC]) that best differentiate benign and malignant lesions (i.e. maximize sensitivity and specificity)
- Develop computer aided assessment tools to facilitate clinical implementation and optimize reader accuracy
Aim 3: Test the performance of the optimized DWI approach for detecting clinically and mammographically-occult cancer in women with dense breasts.
- Conduct a controlled reader study of non-contrast DWI alone for breast cancer detection
- Perform receiver operating characteristic (ROC) analysis and determine the sensitivity and specificity for detection of mammographically occult cancer
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Oregon
-
Portland, Oregon, Stati Uniti, 97239
- Oregon Health & Science University
-
-
Washington
-
Seattle, Washington, Stati Uniti, 98109
- Seattle Cancer Care Alliance
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Women age 18+, with mammographically identified dense breasts, referred for clinical breast MRI
Descrizione
Inclusion Criteria:
- Women aged 18 or older
- Dense breast identified on mammogram
Exclusion Criteria:
- Contra-indication to contrast-enhanced breast MRI (e.g. renal insufficiency with GFR<60, contrast allergy, incompatible metal)
- Patients who currently are undergoing chemoprevention therapy (e.g. aromatase inhibitors or selective estrogen receptor modulators)
- Women who are pregnant
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: COHORT
- Prospettive temporali: PROSPECTIVE
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
Phase 1: Pilot Study Phase
Optimize DWI sequences to maximize spatial resolution, reduce distortion, and increase lesion contrast. |
Diffusion-weighted imaging (DWI) is a non-contrast MRI technique that typically can be acquired in under 5 minutes. DWI reflects the microscopic cellular environment and can demonstrate differences between normal and malignant breast tissue without the aid of intravenous gadolinium. |
|
Phase 2: Development Phase
Develop interpretation tools to optimize diagnostic performance for detecting cx on DWI. |
Non-contrast MRI scans will include DWI along with anatomical T1-weighted and T2-weighted sequences. |
|
Phase 3: Reader Performance Phase
Test the performance of the optimized DWI approach for detecting clinically and mammographically-occult cancer in women with dense breasts. |
Non-contrast MRI scans will include DWI along with anatomical T1-weighted and T2-weighted sequences. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Diffusion sensitization (b value)
Lasso di tempo: 2.5 years
|
Identify optimal b value to maximize conspicuity of cancers in women with dense breasts |
2.5 years
|
|
Reader Interpretation strategy
Lasso di tempo: 3.5 years
|
Identify optimal ADC thresholds to differentiate malignant from benign lesions |
3.5 years
|
|
Specificity
Lasso di tempo: 4.5 years
|
Specificity will be assessed for non-contrast DWI |
4.5 years
|
|
Sensitivity
Lasso di tempo: 4.5 years
|
Sensitivity will be assessed for non-contrast DWI |
4.5 years
|
Collaboratori e investigatori
Sponsor
Collaboratori
Investigatori
- Investigatore principale: Savannah Partridge, Fred Hutch/University of Washington Cancer Consortium
Pubblicazioni e link utili
Pubblicazioni generali
- Biswas D, Hippe DS, Wang Y, DelPriore MR, Zecevic M, Scheel JR, Rahbar H, Partridge SC. Accelerated Breast Diffusion-weighted Imaging Using Multiband Sensitivity Encoding with the CAIPIRINHA Method: Clinical Experience at 3 T. Radiol Imaging Cancer. 2022 Jan;4(1):e210063. doi: 10.1148/rycan.210063.
- Ha SM, Chang JM, Lee SH, Kim ES, Kim SY, Kim YS, Cho N, Moon WK. Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound. Korean J Radiol. 2021 Jun;22(6):867-879. doi: 10.3348/kjr.2020.1183. Epub 2021 Apr 1.
- Oviedo F, Kazerouni AS, Liznerski P, Xu Y, Hirano M, Vandermeulen RA, Kloft M, Blum E, Alessio AM, Li CI, Weeks WB, Dodhia R, Lavista Ferres JM, Rahbar H, Partridge SC. Cancer Detection in Breast MRI Screening via Explainable AI Anomaly Detection. Radiology. 2025 Jul;316(1):e241629. doi: 10.1148/radiol.241629.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 9785
- RG3017005 (Altro identificatore: Fred Hutch/University of Washington Cancer Consortium)
- R01CA207290 (Sovvenzione/contratto NIH degli Stati Uniti)
- NCI-2020-05585 (Identificatore di registro: CTRP (Clinical Trial Reporting Program))
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .