- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT03607552
Ikke-kontrast DWI til supplerende screening
Ikke-kontrast DWI til supplerende screening af kvinder med tætte bryster
Diffusion-weighted imaging (DWI) is a short (under 5 minutes) non-contrast MRI technique that has shown promise for the detection and characterization of breast cancer. Our preliminary data has shown that DWI holds potential for detecting mammographically and clinically-occult breast cancers. However, current technical limitations reduce the sensitivity of DWI for screening applications.
The identification of a screening tool to complement mammography that is more accurate than ultrasound and faster, less expensive, and safer than conventional contrast-enhanced MRI would have significant clinical impact by improving the early detection of cancer in women with dense breasts. We hypothesize that an optimized DWI approach will enable detection of mammographically occult breast cancer in women with dense breasts with high sensitivity and low false positive rate.
Studieoversigt
Status
Betingelser
Intervention / Behandling
Detaljeret beskrivelse
Hypothesis: With technical optimizations, non-contrast DWI can detect clinically and mammographically occult breast cancer in women with dense breasts with high sensitivity and low false positive rate.
Aim 1: Improve the breast DWI technique to maximize spatial resolution, reduce distortion, and increase lesion contrast.
- Develop novel DWI acquisition to increase spatial resolution and reduce distortion (using reduced field of-view and/or multishot echo planar imaging techniques)
- Identify optimal diffusion sensitization (b-value) to maximize conspicuity of cancers in women with dense breasts
Aim 2: Develop interpretation tools to optimize diagnostic performance for detecting cancer on DWI.
- Determine quantitative DWI thresholds (contrast-to-noise ratio, apparent diffusion coefficient [ADC]) that best differentiate benign and malignant lesions (i.e. maximize sensitivity and specificity)
- Develop computer aided assessment tools to facilitate clinical implementation and optimize reader accuracy
Aim 3: Test the performance of the optimized DWI approach for detecting clinically and mammographically-occult cancer in women with dense breasts.
- Conduct a controlled reader study of non-contrast DWI alone for breast cancer detection
- Perform receiver operating characteristic (ROC) analysis and determine the sensitivity and specificity for detection of mammographically occult cancer
Undersøgelsestype
Tilmelding (Faktiske)
Kontakter og lokationer
Studiesteder
-
-
Oregon
-
Portland, Oregon, Forenede Stater, 97239
- Oregon Health & Science University
-
-
Washington
-
Seattle, Washington, Forenede Stater, 98109
- Seattle Cancer Care Alliance
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Prøveudtagningsmetode
Studiebefolkning
Women age 18+, with mammographically identified dense breasts, referred for clinical breast MRI
Beskrivelse
Inclusion Criteria:
- Women aged 18 or older
- Dense breast identified on mammogram
Exclusion Criteria:
- Contra-indication to contrast-enhanced breast MRI (e.g. renal insufficiency with GFR<60, contrast allergy, incompatible metal)
- Patients who currently are undergoing chemoprevention therapy (e.g. aromatase inhibitors or selective estrogen receptor modulators)
- Women who are pregnant
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Observationsmodeller: COHORT
- Tidsperspektiver: PROSPECTIVE
Kohorter og interventioner
Gruppe / kohorte |
Intervention / Behandling |
|---|---|
|
Phase 1: Pilot Study Phase
Optimize DWI sequences to maximize spatial resolution, reduce distortion, and increase lesion contrast. |
Diffusion-weighted imaging (DWI) is a non-contrast MRI technique that typically can be acquired in under 5 minutes. DWI reflects the microscopic cellular environment and can demonstrate differences between normal and malignant breast tissue without the aid of intravenous gadolinium. |
|
Phase 2: Development Phase
Develop interpretation tools to optimize diagnostic performance for detecting cx on DWI. |
Non-contrast MRI scans will include DWI along with anatomical T1-weighted and T2-weighted sequences. |
|
Phase 3: Reader Performance Phase
Test the performance of the optimized DWI approach for detecting clinically and mammographically-occult cancer in women with dense breasts. |
Non-contrast MRI scans will include DWI along with anatomical T1-weighted and T2-weighted sequences. |
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Diffusion sensitization (b value)
Tidsramme: 2.5 years
|
Identify optimal b value to maximize conspicuity of cancers in women with dense breasts |
2.5 years
|
|
Reader Interpretation strategy
Tidsramme: 3.5 years
|
Identify optimal ADC thresholds to differentiate malignant from benign lesions |
3.5 years
|
|
Specificity
Tidsramme: 4.5 years
|
Specificity will be assessed for non-contrast DWI |
4.5 years
|
|
Sensitivity
Tidsramme: 4.5 years
|
Sensitivity will be assessed for non-contrast DWI |
4.5 years
|
Samarbejdspartnere og efterforskere
Sponsor
Samarbejdspartnere
Efterforskere
- Ledende efterforsker: Savannah Partridge, Fred Hutch/University of Washington Cancer Consortium
Publikationer og nyttige links
Generelle publikationer
- Biswas D, Hippe DS, Wang Y, DelPriore MR, Zecevic M, Scheel JR, Rahbar H, Partridge SC. Accelerated Breast Diffusion-weighted Imaging Using Multiband Sensitivity Encoding with the CAIPIRINHA Method: Clinical Experience at 3 T. Radiol Imaging Cancer. 2022 Jan;4(1):e210063. doi: 10.1148/rycan.210063.
- Ha SM, Chang JM, Lee SH, Kim ES, Kim SY, Kim YS, Cho N, Moon WK. Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound. Korean J Radiol. 2021 Jun;22(6):867-879. doi: 10.3348/kjr.2020.1183. Epub 2021 Apr 1.
- Oviedo F, Kazerouni AS, Liznerski P, Xu Y, Hirano M, Vandermeulen RA, Kloft M, Blum E, Alessio AM, Li CI, Weeks WB, Dodhia R, Lavista Ferres JM, Rahbar H, Partridge SC. Cancer Detection in Breast MRI Screening via Explainable AI Anomaly Detection. Radiology. 2025 Jul;316(1):e241629. doi: 10.1148/radiol.241629.
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Anslået)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- 9785
- RG3017005 (Anden identifikator: Fred Hutch/University of Washington Cancer Consortium)
- R01CA207290 (U.S. NIH-bevilling/kontrakt)
- NCI-2020-05585 (Registry Identifier: CTRP (Clinical Trial Reporting Program))
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .