BiVACOR® 完全人工心臓の早期実現可能性研究
The purpose of this study is to assess the feasibility of using the BiVACOR Total Artificial Heart (TAH) System to support adult patients with severe biventricular heart failure, or univentricular heart failure in which left ventricular assist device (LVAD) support is not recommended, who require mechanical circulatory support to sustain life. The BiVACOR TAH System is intended for use as a bridge to transplant (BTT). Feasibility will be assessed by evaluating safety and performance of the BiVACOR TAH System in study subjects.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
研究の種類
研究の種類
入学 (推定)
入学
段階
段階
- 適用できない
連絡先と場所
研究連絡先
研究連絡先
- 名前:Diane Covington
- 電話番号:480-794-0232
- メール:dcovington@crconcepts-cro.com
研究連絡先のバックアップ
- 名前:Nicole Bartnikowski
- 電話番号:657-540-9616
- メール:nicole.bartnikowski@bivacor.com
研究場所
-
-
Arizona
-
Phoenix、Arizona、アメリカ、85006
- 募集
- Banner - University Medical Center Phoenix
-
コンタクト:
- Francisco Arabia, MD, MBA
- 電話番号:602-377-9310
- メール:francisco.arabia@bannerhealth.com
-
-
North Carolina
-
Durham、North Carolina、アメリカ、27710
- 募集
- Duke University Hospital
-
コンタクト:
- Carmelo Milano, MD
- 電話番号:919-684-3243
- メール:carmelo.milano@duke.edu
-
-
Ohio
-
Cincinnati、Ohio、アメリカ、45219
- 募集
- The Christ Hospital
-
コンタクト:
- Robert D. Dowling, MD
- 電話番号:513-585-4880
- メール:robert.dowling@thechristhospital.com
-
-
Texas
-
Houston、Texas、アメリカ、77030
- 募集
- Texas Heart Institute / Baylor St. Luke's Medical Center
-
コンタクト:
- Joseph G. Rogers, MD
- 電話番号:731-790-9401
- メール:jrogers@texasheart.org
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
-
Patient has severe, irreversible biventricular heart failure and is eligible for biventricular mechanical circulatory support based on the International Society of Heart and Lung Transplantation (ISHLT) guidelines or has univentricular heart failure in which LVAD support is not recommended. ISHLT Guidelines for Biventricular Support:
-
Biventricular failure with at least two of the following hemodynamic and/or echocardiographic measurements.
- Right ventricular ejection fraction (RVEF) ≤ 30%
- Right ventricular stroke work index (RVSWI) ≤ 0.25 g/m/beat/m2
- Tricuspid annular plane systolic excursion (TAPSE) ≤ 14 mm
- Right ventricular (RV) to left ventricular (LV) end-diastolic diameter ratio > 0.72
- Central venous pressure (CVP) > 15mmHg
- CVP to pulmonary capillary wedge pressure (PCWP) ratio > 0.63
- Tricuspid insufficiency grade 4
- Pulmonary artery pressure index (PAPi) < 2
-
Treatment-refractory recurrent and sustained ventricular tachycardia or ventricular fibrillation in the presence of untreatable arrhythmogenic pathologic substrate.
-
Heart failure due to restrictive or constrictive physiology (e.g., hypertrophic cardiomyopathy, cardiac amyloidosis/senile or other infiltrative heart disease).
-
-
Patient is categorized as INTERMACS Patient Profile Classification 2 or 3.
-
Patient is classified as NYHA Class IV.
-
Patient has a left ventricular ejection fraction (LVEF) ≤ 25%, with the exception of patients with restrictive or constrictive physiology.
-
Patient is inotrope dependent, OR has a cardiac index (CI) ≤ 2.2 L/min/m2 without inotropes if inotropes are contraindicated (e.g., restrictive or constrictive heart failure), and meets one of the following criteria:
- Is on optimal medical management (OMM), based on current heart failure practice guidelines for at least 45 out of the last 60 days and is failing to respond or is not able to tolerate OMM; or
- Has advanced heart failure for at least 14 days and is dependent on an intra-aortic balloon pump (IABP) or similar temporary mechanical circulatory support device (MCSD) for at least seven days.
-
Patient is eligible for cardiac transplantation as determined by the implanting center.
-
Patient has adequate room in the chest as determined by 3-D imaging or other standard clinical assessments.
-
Patient has read and understands the informed consent form (ICF) and has voluntarily provided informed consent.
Exclusion Criteria:
-
Patient has contraindications to anticoagulation or antiplatelet therapies.
-
Patient has coagulopathy defined by a platelet count < 50 k/µl.
-
Patient has insufficient space in the chest to accommodate the BiVACOR pump.
-
Patient has a body mass index (BMI) ≥ 35 kg/m2.
-
Patient is highly pre-sensitized prior to pump implantation.
-
Patient is unconscious and unresponsive.
-
Patient is on pre-implant extracorporeal membrane oxygenation (ECMO) for > 7 days.
-
Patient is on pre-implant temporary MCSD for more than 21 days [e.g., Intra-aortic balloon pump (IABP), Impella, CentriMag, etc.] unless ambulatory and free from adverse effects associated with the MCSD.
-
Patient is implanted with durable mechanical circulatory support (LVAD or RVAD).
-
Patient experienced cerebrovascular accident (CVA) within three months of eligibility evaluation.
-
Patient has severe end-organ dysfunction as evidenced by:
- Total bilirubin > 4.0 mg/dL or cirrhosis confirmed by imaging or positive biopsy, and/or
- Glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 or renal replacement therapy dependence.
-
Patient has severe chronic obstructive pulmonary disease (COPD) or restrictive lung disease requiring home oxygen.
-
Patient has primary pulmonary hypertension ≥ 8 Wood units.
-
Patient has severe systemic light-chain amyloidosis.
-
Patient has been diagnosed with severe cardiac cachexia or irreversible frailty.
-
Patient has diabetes with advanced diabetic neuropathy with accompanying skin ulceration.
-
Patient has a blood-borne infection within seven days of eligibility evaluation. Positive blood cultures reflective of contaminants (e.g., Staphylococcus epidermidis) will not be considered an exclusion.
-
Patient is pregnant or planning pregnancy.
-
Patient has a co-morbidity or illness that would limit survival to less than two years.
-
Patient has a current drug and/or alcohol addiction or known substance abuse.
-
Patient has insufficient social support or a history of non-compliance with medical instructions as determined by the Investigator.
-
Patient is participating in another clinical trial that may impact or confound the results of the BiVACOR TAH EFS.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:デバイスの実現可能性
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:BiVACOR TAH
The BiVACOR TAH System will be implanted as a bridge to transplant (BTT) for adults with severe irreversible biventricular heart failure or univentricular heart failure in which LVAD support is not recommended, and who are eligible for cardiac transplantation. |
The BiVACOR pump is an implantable rotary biventricular blood pump that uses magnetic levitation technology for increased durability to replace both ventricles of a failing heart. The device is intended to replace the diseased heart in patients suffering from heart failure to bridge the time to heart transplant. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Feasibility Endpoint
時間枠:6 months or time of heart transplant (if prior to 6 months post pump implant)
|
Survival on the original BiVACOR pump |
6 months or time of heart transplant (if prior to 6 months post pump implant)
|
|
Safety Endpoint
時間枠:Through 6 months
|
Evaluation of the safety of the BiVACOR TAH System using INTERMACS adverse event (AE) terms and definitions (INTERMACS Manual of Operations Version 5). |
Through 6 months
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。