Tidlig gennemførlighedsundersøgelse af BiVACOR® Total Artificial Heart
The purpose of this study is to assess the feasibility of using the BiVACOR Total Artificial Heart (TAH) System to support adult patients with severe biventricular heart failure, or univentricular heart failure in which left ventricular assist device (LVAD) support is not recommended, who require mechanical circulatory support to sustain life. The BiVACOR TAH System is intended for use as a bridge to transplant (BTT). Feasibility will be assessed by evaluating safety and performance of the BiVACOR TAH System in study subjects.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Anslået)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiekontakt
Studiekontakt
- Navn: Diane Covington
- Telefonnummer: 480-794-0232
- E-mail: dcovington@crconcepts-cro.com
Undersøgelse Kontakt Backup
- Navn: Nicole Bartnikowski
- Telefonnummer: 657-540-9616
- E-mail: nicole.bartnikowski@bivacor.com
Studiesteder
-
-
Arizona
-
Phoenix, Arizona, Forenede Stater, 85006
- Rekruttering
- Banner - University Medical Center Phoenix
-
Kontakt:
- Francisco Arabia, MD, MBA
- Telefonnummer: 602-377-9310
- E-mail: francisco.arabia@bannerhealth.com
-
-
North Carolina
-
Durham, North Carolina, Forenede Stater, 27710
- Rekruttering
- Duke University Hospital
-
Kontakt:
- Carmelo Milano, MD
- Telefonnummer: 919-684-3243
- E-mail: carmelo.milano@duke.edu
-
-
Ohio
-
Cincinnati, Ohio, Forenede Stater, 45219
- Rekruttering
- The Christ Hospital
-
Kontakt:
- Robert D. Dowling, MD
- Telefonnummer: 513-585-4880
- E-mail: robert.dowling@thechristhospital.com
-
-
Texas
-
Houston, Texas, Forenede Stater, 77030
- Rekruttering
- Texas Heart Institute / Baylor St. Luke's Medical Center
-
Kontakt:
- Joseph G. Rogers, MD
- Telefonnummer: 731-790-9401
- E-mail: jrogers@texasheart.org
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
-
Patient has severe, irreversible biventricular heart failure and is eligible for biventricular mechanical circulatory support based on the International Society of Heart and Lung Transplantation (ISHLT) guidelines or has univentricular heart failure in which LVAD support is not recommended. ISHLT Guidelines for Biventricular Support:
-
Biventricular failure with at least two of the following hemodynamic and/or echocardiographic measurements.
- Right ventricular ejection fraction (RVEF) ≤ 30%
- Right ventricular stroke work index (RVSWI) ≤ 0.25 g/m/beat/m2
- Tricuspid annular plane systolic excursion (TAPSE) ≤ 14 mm
- Right ventricular (RV) to left ventricular (LV) end-diastolic diameter ratio > 0.72
- Central venous pressure (CVP) > 15mmHg
- CVP to pulmonary capillary wedge pressure (PCWP) ratio > 0.63
- Tricuspid insufficiency grade 4
- Pulmonary artery pressure index (PAPi) < 2
-
Treatment-refractory recurrent and sustained ventricular tachycardia or ventricular fibrillation in the presence of untreatable arrhythmogenic pathologic substrate.
-
Heart failure due to restrictive or constrictive physiology (e.g., hypertrophic cardiomyopathy, cardiac amyloidosis/senile or other infiltrative heart disease).
-
-
Patient is categorized as INTERMACS Patient Profile Classification 2 or 3.
-
Patient is classified as NYHA Class IV.
-
Patient has a left ventricular ejection fraction (LVEF) ≤ 25%, with the exception of patients with restrictive or constrictive physiology.
-
Patient is inotrope dependent, OR has a cardiac index (CI) ≤ 2.2 L/min/m2 without inotropes if inotropes are contraindicated (e.g., restrictive or constrictive heart failure), and meets one of the following criteria:
- Is on optimal medical management (OMM), based on current heart failure practice guidelines for at least 45 out of the last 60 days and is failing to respond or is not able to tolerate OMM; or
- Has advanced heart failure for at least 14 days and is dependent on an intra-aortic balloon pump (IABP) or similar temporary mechanical circulatory support device (MCSD) for at least seven days.
-
Patient is eligible for cardiac transplantation as determined by the implanting center.
-
Patient has adequate room in the chest as determined by 3-D imaging or other standard clinical assessments.
-
Patient has read and understands the informed consent form (ICF) and has voluntarily provided informed consent.
Exclusion Criteria:
-
Patient has contraindications to anticoagulation or antiplatelet therapies.
-
Patient has coagulopathy defined by a platelet count < 50 k/µl.
-
Patient has insufficient space in the chest to accommodate the BiVACOR pump.
-
Patient has a body mass index (BMI) ≥ 35 kg/m2.
-
Patient is highly pre-sensitized prior to pump implantation.
-
Patient is unconscious and unresponsive.
-
Patient is on pre-implant extracorporeal membrane oxygenation (ECMO) for > 7 days.
-
Patient is on pre-implant temporary MCSD for more than 21 days [e.g., Intra-aortic balloon pump (IABP), Impella, CentriMag, etc.] unless ambulatory and free from adverse effects associated with the MCSD.
-
Patient is implanted with durable mechanical circulatory support (LVAD or RVAD).
-
Patient experienced cerebrovascular accident (CVA) within three months of eligibility evaluation.
-
Patient has severe end-organ dysfunction as evidenced by:
- Total bilirubin > 4.0 mg/dL or cirrhosis confirmed by imaging or positive biopsy, and/or
- Glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 or renal replacement therapy dependence.
-
Patient has severe chronic obstructive pulmonary disease (COPD) or restrictive lung disease requiring home oxygen.
-
Patient has primary pulmonary hypertension ≥ 8 Wood units.
-
Patient has severe systemic light-chain amyloidosis.
-
Patient has been diagnosed with severe cardiac cachexia or irreversible frailty.
-
Patient has diabetes with advanced diabetic neuropathy with accompanying skin ulceration.
-
Patient has a blood-borne infection within seven days of eligibility evaluation. Positive blood cultures reflective of contaminants (e.g., Staphylococcus epidermidis) will not be considered an exclusion.
-
Patient is pregnant or planning pregnancy.
-
Patient has a co-morbidity or illness that would limit survival to less than two years.
-
Patient has a current drug and/or alcohol addiction or known substance abuse.
-
Patient has insufficient social support or a history of non-compliance with medical instructions as determined by the Investigator.
-
Patient is participating in another clinical trial that may impact or confound the results of the BiVACOR TAH EFS.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Enhedens gennemførlighed
- Tildeling: N/A
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: BiVACOR TAH
The BiVACOR TAH System will be implanted as a bridge to transplant (BTT) for adults with severe irreversible biventricular heart failure or univentricular heart failure in which LVAD support is not recommended, and who are eligible for cardiac transplantation. |
The BiVACOR pump is an implantable rotary biventricular blood pump that uses magnetic levitation technology for increased durability to replace both ventricles of a failing heart. The device is intended to replace the diseased heart in patients suffering from heart failure to bridge the time to heart transplant. |
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Feasibility Endpoint
Tidsramme: 6 months or time of heart transplant (if prior to 6 months post pump implant)
|
Survival on the original BiVACOR pump |
6 months or time of heart transplant (if prior to 6 months post pump implant)
|
|
Safety Endpoint
Tidsramme: Through 6 months
|
Evaluation of the safety of the BiVACOR TAH System using INTERMACS adverse event (AE) terms and definitions (INTERMACS Manual of Operations Version 5). |
Through 6 months
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Anslået)
Primær færdiggørelse
Studieafslutning (Anslået)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- CP-0001
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .