Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

BiVACOR® Total Artificial Heart Frühe Machbarkeitsstudie

24. September 2026 aktualisiert von: BiVACOR Inc.

The purpose of this study is to assess the feasibility of using the BiVACOR Total Artificial Heart (TAH) System to support adult patients with severe biventricular heart failure, or univentricular heart failure in which left ventricular assist device (LVAD) support is not recommended, who require mechanical circulatory support to sustain life. The BiVACOR TAH System is intended for use as a bridge to transplant (BTT). Feasibility will be assessed by evaluating safety and performance of the BiVACOR TAH System in study subjects.

Studienübersicht

Status

Rekrutierung

Bedingungen

Intervention / Behandlung

Studientyp

Interventionell

Einschreibung (Geschätzt)

20

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Studienorte

    • Arizona
      • Phoenix, Arizona, Vereinigte Staaten, 85006
    • North Carolina
      • Durham, North Carolina, Vereinigte Staaten, 27710
        • Rekrutierung
        • Duke University Hospital
        • Kontakt:
    • Ohio
      • Cincinnati, Ohio, Vereinigte Staaten, 45219
    • Texas
      • Houston, Texas, Vereinigte Staaten, 77030
        • Rekrutierung
        • Texas Heart Institute / Baylor St. Luke's Medical Center
        • Kontakt:

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre bis 70 Jahre (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Patient has severe, irreversible biventricular heart failure and is eligible for biventricular mechanical circulatory support based on the International Society of Heart and Lung Transplantation (ISHLT) guidelines or has univentricular heart failure in which LVAD support is not recommended. ISHLT Guidelines for Biventricular Support:

    1. Biventricular failure with at least two of the following hemodynamic and/or echocardiographic measurements.

      1. Right ventricular ejection fraction (RVEF) ≤ 30%
      2. Right ventricular stroke work index (RVSWI) ≤ 0.25 g/m/beat/m2
      3. Tricuspid annular plane systolic excursion (TAPSE) ≤ 14 mm
      4. Right ventricular (RV) to left ventricular (LV) end-diastolic diameter ratio > 0.72
      5. Central venous pressure (CVP) > 15mmHg
      6. CVP to pulmonary capillary wedge pressure (PCWP) ratio > 0.63
      7. Tricuspid insufficiency grade 4
      8. Pulmonary artery pressure index (PAPi) < 2
    2. Treatment-refractory recurrent and sustained ventricular tachycardia or ventricular fibrillation in the presence of untreatable arrhythmogenic pathologic substrate.

    3. Heart failure due to restrictive or constrictive physiology (e.g., hypertrophic cardiomyopathy, cardiac amyloidosis/senile or other infiltrative heart disease).

  • Patient is categorized as INTERMACS Patient Profile Classification 2 or 3.

  • Patient is classified as NYHA Class IV.

  • Patient has a left ventricular ejection fraction (LVEF) ≤ 25%, with the exception of patients with restrictive or constrictive physiology.

  • Patient is inotrope dependent, OR has a cardiac index (CI) ≤ 2.2 L/min/m2 without inotropes if inotropes are contraindicated (e.g., restrictive or constrictive heart failure), and meets one of the following criteria:

    1. Is on optimal medical management (OMM), based on current heart failure practice guidelines for at least 45 out of the last 60 days and is failing to respond or is not able to tolerate OMM; or
    2. Has advanced heart failure for at least 14 days and is dependent on an intra-aortic balloon pump (IABP) or similar temporary mechanical circulatory support device (MCSD) for at least seven days.
  • Patient is eligible for cardiac transplantation as determined by the implanting center.

  • Patient has adequate room in the chest as determined by 3-D imaging or other standard clinical assessments.

  • Patient has read and understands the informed consent form (ICF) and has voluntarily provided informed consent.

Exclusion Criteria:

  • Patient has contraindications to anticoagulation or antiplatelet therapies.

  • Patient has coagulopathy defined by a platelet count < 50 k/µl.

  • Patient has insufficient space in the chest to accommodate the BiVACOR pump.

  • Patient has a body mass index (BMI) ≥ 35 kg/m2.

  • Patient is highly pre-sensitized prior to pump implantation.

  • Patient is unconscious and unresponsive.

  • Patient is on pre-implant extracorporeal membrane oxygenation (ECMO) for > 7 days.

  • Patient is on pre-implant temporary MCSD for more than 21 days [e.g., Intra-aortic balloon pump (IABP), Impella, CentriMag, etc.] unless ambulatory and free from adverse effects associated with the MCSD.

  • Patient is implanted with durable mechanical circulatory support (LVAD or RVAD).

  • Patient experienced cerebrovascular accident (CVA) within three months of eligibility evaluation.

  • Patient has severe end-organ dysfunction as evidenced by:

    1. Total bilirubin > 4.0 mg/dL or cirrhosis confirmed by imaging or positive biopsy, and/or
    2. Glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 or renal replacement therapy dependence.
  • Patient has severe chronic obstructive pulmonary disease (COPD) or restrictive lung disease requiring home oxygen.

  • Patient has primary pulmonary hypertension ≥ 8 Wood units.

  • Patient has severe systemic light-chain amyloidosis.

  • Patient has been diagnosed with severe cardiac cachexia or irreversible frailty.

  • Patient has diabetes with advanced diabetic neuropathy with accompanying skin ulceration.

  • Patient has a blood-borne infection within seven days of eligibility evaluation. Positive blood cultures reflective of contaminants (e.g., Staphylococcus epidermidis) will not be considered an exclusion.

  • Patient is pregnant or planning pregnancy.

  • Patient has a co-morbidity or illness that would limit survival to less than two years.

  • Patient has a current drug and/or alcohol addiction or known substance abuse.

  • Patient has insufficient social support or a history of non-compliance with medical instructions as determined by the Investigator.

  • Patient is participating in another clinical trial that may impact or confound the results of the BiVACOR TAH EFS.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Machbarkeit des Geräts
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: BiVACOR TAH

The BiVACOR TAH System will be implanted as a bridge to transplant (BTT) for adults with severe irreversible biventricular heart failure or univentricular heart failure in which LVAD support is not recommended, and who are eligible for cardiac transplantation.

The BiVACOR pump is an implantable rotary biventricular blood pump that uses magnetic levitation technology for increased durability to replace both ventricles of a failing heart. The device is intended to replace the diseased heart in patients suffering from heart failure to bridge the time to heart transplant.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Feasibility Endpoint
Zeitfenster: 6 months or time of heart transplant (if prior to 6 months post pump implant)

Survival on the original BiVACOR pump

6 months or time of heart transplant (if prior to 6 months post pump implant)
Safety Endpoint
Zeitfenster: Through 6 months

Evaluation of the safety of the BiVACOR TAH System using INTERMACS adverse event (AE) terms and definitions (INTERMACS Manual of Operations Version 5).

Through 6 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

26. Juni 2024

Primärer Abschluss (Geschätzt)

1. Dezember 2026

Studienabschluss (Geschätzt)

1. März 2027

Studienanmeldedaten

Zuerst eingereicht

8. Dezember 2023

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

8. Dezember 2023

Zuerst gepostet (Tatsächlich)

18. Dezember 2023

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

28. September 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

24. September 2026

Zuletzt verifiziert

1. Mai 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Zusätzliche relevante MeSH-Bedingungen

Andere Studien-ID-Nummern

  • CP-0001

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .