BiVACOR® 전체 인공 심장 조기 타당성 조사
The purpose of this study is to assess the feasibility of using the BiVACOR Total Artificial Heart (TAH) System to support adult patients with severe biventricular heart failure, or univentricular heart failure in which left ventricular assist device (LVAD) support is not recommended, who require mechanical circulatory support to sustain life. The BiVACOR TAH System is intended for use as a bridge to transplant (BTT). Feasibility will be assessed by evaluating safety and performance of the BiVACOR TAH System in study subjects.
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
연구 유형
연구 유형
등록 (추정된)
등록
단계
단계
- 해당 없음
연락처 및 위치
연구 연락처
연구 연락처
- 이름: Diane Covington
- 전화번호: 480-794-0232
- 이메일: dcovington@crconcepts-cro.com
연구 연락처 백업
- 이름: Nicole Bartnikowski
- 전화번호: 657-540-9616
- 이메일: nicole.bartnikowski@bivacor.com
연구 장소
-
-
Arizona
-
Phoenix, Arizona, 미국, 85006
- 모병
- Banner - University Medical Center Phoenix
-
연락하다:
- Francisco Arabia, MD, MBA
- 전화번호: 602-377-9310
- 이메일: francisco.arabia@bannerhealth.com
-
-
North Carolina
-
Durham, North Carolina, 미국, 27710
- 모병
- Duke University Hospital
-
연락하다:
- Carmelo Milano, MD
- 전화번호: 919-684-3243
- 이메일: carmelo.milano@duke.edu
-
-
Ohio
-
Cincinnati, Ohio, 미국, 45219
- 모병
- The Christ Hospital
-
연락하다:
- Robert D. Dowling, MD
- 전화번호: 513-585-4880
- 이메일: robert.dowling@thechristhospital.com
-
-
Texas
-
Houston, Texas, 미국, 77030
- 모병
- Texas Heart Institute / Baylor St. Luke's Medical Center
-
연락하다:
- Joseph G. Rogers, MD
- 전화번호: 731-790-9401
- 이메일: jrogers@texasheart.org
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
-
Patient has severe, irreversible biventricular heart failure and is eligible for biventricular mechanical circulatory support based on the International Society of Heart and Lung Transplantation (ISHLT) guidelines or has univentricular heart failure in which LVAD support is not recommended. ISHLT Guidelines for Biventricular Support:
-
Biventricular failure with at least two of the following hemodynamic and/or echocardiographic measurements.
- Right ventricular ejection fraction (RVEF) ≤ 30%
- Right ventricular stroke work index (RVSWI) ≤ 0.25 g/m/beat/m2
- Tricuspid annular plane systolic excursion (TAPSE) ≤ 14 mm
- Right ventricular (RV) to left ventricular (LV) end-diastolic diameter ratio > 0.72
- Central venous pressure (CVP) > 15mmHg
- CVP to pulmonary capillary wedge pressure (PCWP) ratio > 0.63
- Tricuspid insufficiency grade 4
- Pulmonary artery pressure index (PAPi) < 2
-
Treatment-refractory recurrent and sustained ventricular tachycardia or ventricular fibrillation in the presence of untreatable arrhythmogenic pathologic substrate.
-
Heart failure due to restrictive or constrictive physiology (e.g., hypertrophic cardiomyopathy, cardiac amyloidosis/senile or other infiltrative heart disease).
-
-
Patient is categorized as INTERMACS Patient Profile Classification 2 or 3.
-
Patient is classified as NYHA Class IV.
-
Patient has a left ventricular ejection fraction (LVEF) ≤ 25%, with the exception of patients with restrictive or constrictive physiology.
-
Patient is inotrope dependent, OR has a cardiac index (CI) ≤ 2.2 L/min/m2 without inotropes if inotropes are contraindicated (e.g., restrictive or constrictive heart failure), and meets one of the following criteria:
- Is on optimal medical management (OMM), based on current heart failure practice guidelines for at least 45 out of the last 60 days and is failing to respond or is not able to tolerate OMM; or
- Has advanced heart failure for at least 14 days and is dependent on an intra-aortic balloon pump (IABP) or similar temporary mechanical circulatory support device (MCSD) for at least seven days.
-
Patient is eligible for cardiac transplantation as determined by the implanting center.
-
Patient has adequate room in the chest as determined by 3-D imaging or other standard clinical assessments.
-
Patient has read and understands the informed consent form (ICF) and has voluntarily provided informed consent.
Exclusion Criteria:
-
Patient has contraindications to anticoagulation or antiplatelet therapies.
-
Patient has coagulopathy defined by a platelet count < 50 k/µl.
-
Patient has insufficient space in the chest to accommodate the BiVACOR pump.
-
Patient has a body mass index (BMI) ≥ 35 kg/m2.
-
Patient is highly pre-sensitized prior to pump implantation.
-
Patient is unconscious and unresponsive.
-
Patient is on pre-implant extracorporeal membrane oxygenation (ECMO) for > 7 days.
-
Patient is on pre-implant temporary MCSD for more than 21 days [e.g., Intra-aortic balloon pump (IABP), Impella, CentriMag, etc.] unless ambulatory and free from adverse effects associated with the MCSD.
-
Patient is implanted with durable mechanical circulatory support (LVAD or RVAD).
-
Patient experienced cerebrovascular accident (CVA) within three months of eligibility evaluation.
-
Patient has severe end-organ dysfunction as evidenced by:
- Total bilirubin > 4.0 mg/dL or cirrhosis confirmed by imaging or positive biopsy, and/or
- Glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 or renal replacement therapy dependence.
-
Patient has severe chronic obstructive pulmonary disease (COPD) or restrictive lung disease requiring home oxygen.
-
Patient has primary pulmonary hypertension ≥ 8 Wood units.
-
Patient has severe systemic light-chain amyloidosis.
-
Patient has been diagnosed with severe cardiac cachexia or irreversible frailty.
-
Patient has diabetes with advanced diabetic neuropathy with accompanying skin ulceration.
-
Patient has a blood-borne infection within seven days of eligibility evaluation. Positive blood cultures reflective of contaminants (e.g., Staphylococcus epidermidis) will not be considered an exclusion.
-
Patient is pregnant or planning pregnancy.
-
Patient has a co-morbidity or illness that would limit survival to less than two years.
-
Patient has a current drug and/or alcohol addiction or known substance abuse.
-
Patient has insufficient social support or a history of non-compliance with medical instructions as determined by the Investigator.
-
Patient is participating in another clinical trial that may impact or confound the results of the BiVACOR TAH EFS.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 장치 타당성
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
팔의 수
무기와 개입
참가자 그룹 / 팔참가자 그룹 / 팔 |
개입 / 치료개입 / 치료 |
|---|---|
|
실험적: BiVACOR TAH
The BiVACOR TAH System will be implanted as a bridge to transplant (BTT) for adults with severe irreversible biventricular heart failure or univentricular heart failure in which LVAD support is not recommended, and who are eligible for cardiac transplantation. |
The BiVACOR pump is an implantable rotary biventricular blood pump that uses magnetic levitation technology for increased durability to replace both ventricles of a failing heart. The device is intended to replace the diseased heart in patients suffering from heart failure to bridge the time to heart transplant. |
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Feasibility Endpoint
기간: 6 months or time of heart transplant (if prior to 6 months post pump implant)
|
Survival on the original BiVACOR pump |
6 months or time of heart transplant (if prior to 6 months post pump implant)
|
|
Safety Endpoint
기간: Through 6 months
|
Evaluation of the safety of the BiVACOR TAH System using INTERMACS adverse event (AE) terms and definitions (INTERMACS Manual of Operations Version 5). |
Through 6 months
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (추정된)
기본 완료
연구 완료 (추정된)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .