このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Outcomes of a Trifocal IOL in Post-refractive Patients (TrIPLe)

2020年10月15日 更新者:Vance Thompson Vision ND
To compare the prediction error of ORA vs formula for post-LASIK cataract patients when PanOptix IOL was implanted. Using post-operative outcomes to determine if preoperative IOL calculations, including Barrett TK, Barrett Universal II, Hill RBF, ASCRS post-refractive calculator, or intraoperative aberrometry is more accurate when the two methods disagree in patients who have had previous refractive surgery undergo cataract surgery.

調査の概要

状態

わからない

条件

詳細な説明

The study will be non-interventional with data being collected prospectively and retrospectively between at least two surgical sites. All subjects will have previous LASIK and be at least 3 months post op PanOptix implantation. The study will enroll up to 200 patients and a statistical database will be created.

研究の種類

観察的

入学 (予想される)

200

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

Charts from up to 200 myopic post-refractive patients who have received PanOptix will be reviewed at at least two Vance Thompson Vision sites (Fargo, ND and Sioux Falls, SD). All patients will have had ORA used during the cataract surgery.

説明

Inclusion Criteria:

  • Previous myopic refractive surgery
  • At least 3 months post op cataract surgery with a trifocal IOL

Exclusion Criteria:

  • Pre-existing or subsequent eye condition that interferes with accurate data collection (retinal detachment, etc.)

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
Post-refractive trifocal IOL
Trifocal IOL with ORA in post refractive patients

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
To determine if preoperative IOL calculations or intraoperative aberrometry is more accurate when the two methods disagree in patients who have had previous refractive surgery undergo cataract surgery.
時間枠:Pre-op to 9 month visit
  1. Percentage of eyes within +/- .5D of target for each formula and ORA.
  2. Overall % of eyes that have a disagreement between the two methods
Pre-op to 9 month visit

二次結果の測定

結果測定
メジャーの説明
時間枠
Post-operative monocular visual acuity
時間枠:3 to 9 month visit
Monocular Uncorrected Distance, Intermediate, Near Visual Acuity
3 to 9 month visit
Post-operative best corrected visual acuity
時間枠:3 to 9 month visit
Manifest refraction, Best Corrected Distance Visual Acuity, Distance Corrected Intermediate, and Near Visual Acuity
3 to 9 month visit
Post-operative uncorrected visual acuity
時間枠:3 to 9 month visit
Binocular Uncorrected Distance, Intermediate, Near Visual Acuity, Best Corrected Distance Visual Acuity, Distance Corrected Intermediate, Near Visual Acuity
3 to 9 month visit
Post-operative visual acuity
時間枠:3 to 9 month visit
Percentage of eyes with Uncorrected Distance Visual Acuity of 20/20 or better, 20/25 or better, and 20/30 or better
3 to 9 month visit
Post-operative visual acuity
時間枠:3 to 9 month visit
Percentage of eyes with Uncorrected Corrected Intermediate Visual Acuity and Distance Corrected Intermediate Visual Acuity 20/20 or better, 20/25 or better, and 20/30 or better
3 to 9 month visit
Post-operative visual acuity
時間枠:3 to 9 month visit
Percentage of eyes with Uncorrected Distance Near Visual Acuity and Distance Corrected Near Visual Acuity of 20/20 or better, 20/25 or better, and 20/30 or better
3 to 9 month visit
Patient's quality of vision and reported side-effects
時間枠:3 to 9 month visit
Patient satisfaction questionnaire
3 to 9 month visit

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Michael Greenwood, MD、Vance Thompson Vision ND

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2020年10月9日

一次修了 (予想される)

2021年3月1日

研究の完了 (予想される)

2021年5月1日

試験登録日

最初に提出

2020年8月21日

QC基準を満たした最初の提出物

2020年9月3日

最初の投稿 (実際)

2020年9月10日

学習記録の更新

投稿された最後の更新 (実際)

2020年10月19日

QC基準を満たした最後の更新が送信されました

2020年10月15日

最終確認日

2020年10月1日

詳しくは

本研究に関する用語

追加の関連 MeSH 用語

その他の研究ID番号

  • IOL-VTV-01

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

はい

米国で製造され、米国から輸出された製品。

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

PanOptixの臨床試験

購読する