비만하지 않은 여성의 진통제를 위한 경막외 공간의 최적 카테터 길이: 4cm 대 5cm의 무작위 대조 시험
Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.
Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.
Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.
This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.
연구 개요
상세 설명
Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.
Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.
The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Ontario
-
Toronto, Ontario, 캐나다, M5G1X5
- Mount Sinai Hospital
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- All women aged 18 years and above.
- 3-7 cm dilation at time of insertion.
- Women with BMI < 40 kg/m2
Exclusion Criteria:
- Known contraindication to epidural insertion.
- Inability or unwillingness to provide written consent.
- Previous difficult epidural insertion.
- Previous failed epidural.
- Imminent instrumental or operative delivery.
- Dural puncture.
- Combined spinal epidural analgesia.
- High BMI > 40 kg/m2
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 삼루타
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
활성 비교기: 4 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 4 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
다른 이름들:
|
|
활성 비교기: 5 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 5 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Composite outcome
기간: 24 hours
|
Presence of any of the individual primary outcomes described below:
|
24 hours
|
|
Sensory block level < T10
기간: 1 hour
|
Sensory block level to ice will be measured 1 hour after the loading dose is administered. Yes: inadequate block No: adequate block |
1 hour
|
|
Block height discrepancy
기간: 24 hours
|
Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery. Yes: inadequate block No: adequate block |
24 hours
|
|
Re-siting of the epidural
기간: 24 hours
|
Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:
|
24 hours
|
|
Adjustment of catheter length
기간: 24 hours
|
Adjustment of catheter length at any time during labour would also indicate an inadequate block. |
24 hours
|
|
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
기간: 24 hours
|
The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist. |
24 hours
|
|
Pain score >3 at any time during labour: questionnaire
기간: 24 hours
|
A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Number of epidural top-ups administered by the nursing team
기간: 24 hours
|
The number of times the labour and delivery nurse has to administer a top-up of the epidural. |
24 hours
|
|
Number of epidural top-ups administered by the anesthesiologist
기간: 24 hours
|
The number of times the anesthesiologist has to administer a top-up of the epidural. |
24 hours
|
|
Pain scores recorded throughout labour: questionnaire
기간: 24 hours
|
A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
|
Hourly sensory block height assessment
기간: 24 hours
|
Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice. |
24 hours
|
|
Incidence of intravascular epidural placement
기간: 24 hours
|
Any incidence of intravascular epidural placement during labour will be recorded. |
24 hours
|
|
Incidence of catheter dislodgement
기간: 24 hours
|
Any incidence of catheter dislodgement during labour will be recorded. |
24 hours
|
|
Motor block using Bromage scale
기간: 24 hours
|
Bromage scale will be recorded hourly as standard practice.
|
24 hours
|
|
Presence of paresthesia on insertion.
기간: 1 hour
|
Any presence of paresthesia on insertion will be recorded. |
1 hour
|
|
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
기간: 24 hours
|
Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist. |
24 hours
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Mrinalini Balki, MD, MOUNT SINAI HOSPITAL
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .