Оптимальная длина катетера в эпидуральном пространстве для обезболивания родов у женщин без ожирения: рандомизированное контролируемое исследование 4 см по сравнению с 5 см
Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.
Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.
Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.
This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.
Обзор исследования
Подробное описание
Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.
Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.
The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.
Тип исследования
Регистрация (Действительный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Ontario
-
Toronto, Ontario, Канада, M5G1X5
- Mount Sinai Hospital
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- All women aged 18 years and above.
- 3-7 cm dilation at time of insertion.
- Women with BMI < 40 kg/m2
Exclusion Criteria:
- Known contraindication to epidural insertion.
- Inability or unwillingness to provide written consent.
- Previous difficult epidural insertion.
- Previous failed epidural.
- Imminent instrumental or operative delivery.
- Dural puncture.
- Combined spinal epidural analgesia.
- High BMI > 40 kg/m2
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Тройной
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Активный компаратор: 4 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 4 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
Другие имена:
|
|
Активный компаратор: 5 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 5 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
Другие имена:
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Composite outcome
Временное ограничение: 24 hours
|
Presence of any of the individual primary outcomes described below:
|
24 hours
|
|
Sensory block level < T10
Временное ограничение: 1 hour
|
Sensory block level to ice will be measured 1 hour after the loading dose is administered. Yes: inadequate block No: adequate block |
1 hour
|
|
Block height discrepancy
Временное ограничение: 24 hours
|
Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery. Yes: inadequate block No: adequate block |
24 hours
|
|
Re-siting of the epidural
Временное ограничение: 24 hours
|
Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:
|
24 hours
|
|
Adjustment of catheter length
Временное ограничение: 24 hours
|
Adjustment of catheter length at any time during labour would also indicate an inadequate block. |
24 hours
|
|
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
Временное ограничение: 24 hours
|
The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist. |
24 hours
|
|
Pain score >3 at any time during labour: questionnaire
Временное ограничение: 24 hours
|
A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Number of epidural top-ups administered by the nursing team
Временное ограничение: 24 hours
|
The number of times the labour and delivery nurse has to administer a top-up of the epidural. |
24 hours
|
|
Number of epidural top-ups administered by the anesthesiologist
Временное ограничение: 24 hours
|
The number of times the anesthesiologist has to administer a top-up of the epidural. |
24 hours
|
|
Pain scores recorded throughout labour: questionnaire
Временное ограничение: 24 hours
|
A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
|
Hourly sensory block height assessment
Временное ограничение: 24 hours
|
Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice. |
24 hours
|
|
Incidence of intravascular epidural placement
Временное ограничение: 24 hours
|
Any incidence of intravascular epidural placement during labour will be recorded. |
24 hours
|
|
Incidence of catheter dislodgement
Временное ограничение: 24 hours
|
Any incidence of catheter dislodgement during labour will be recorded. |
24 hours
|
|
Motor block using Bromage scale
Временное ограничение: 24 hours
|
Bromage scale will be recorded hourly as standard practice.
|
24 hours
|
|
Presence of paresthesia on insertion.
Временное ограничение: 1 hour
|
Any presence of paresthesia on insertion will be recorded. |
1 hour
|
|
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
Временное ограничение: 24 hours
|
Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist. |
24 hours
|
Соавторы и исследователи
Следователи
- Главный следователь: Mrinalini Balki, MD, MOUNT SINAI HOSPITAL
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- 21-06
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .