此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

用于非肥胖女性分娩镇痛的硬膜外腔导管的最佳长度:4 cm 与 5 cm 的随机对照试验

Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.

Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.

Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.

This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.

研究概览

地位

完全的

条件

详细说明

Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.

Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.

The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.

研究类型

介入性

注册 (实际的)

200

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Ontario
      • Toronto、Ontario、加拿大、M5G1X5
        • Mount Sinai Hospital

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 50年 (成人)

接受健康志愿者

是的

有资格学习的性别

女性

描述

Inclusion Criteria:

  • All women aged 18 years and above.
  • 3-7 cm dilation at time of insertion.
  • Women with BMI < 40 kg/m2

Exclusion Criteria:

  • Known contraindication to epidural insertion.
  • Inability or unwillingness to provide written consent.
  • Previous difficult epidural insertion.
  • Previous failed epidural.
  • Imminent instrumental or operative delivery.
  • Dural puncture.
  • Combined spinal epidural analgesia.
  • High BMI > 40 kg/m2

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:三倍

武器和干预

参与者组/臂
干预/治疗
有源比较器:4 cm epidural catheter

The epidural catheter will be thread into the epidural space at a length of 4 cm.

The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

其他名称:
  • 硬膜外
有源比较器:5 cm epidural catheter

The epidural catheter will be thread into the epidural space at a length of 5 cm.

The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

其他名称:
  • 硬膜外

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Composite outcome
大体时间:24 hours

Presence of any of the individual primary outcomes described below:

  • Sensory block level <T10
  • VRNS pain score >3
  • Block height dicrepancy (unilateral or asymmetric block)
  • Re-siting of the epidural
  • Adjustment of catheter length
  • Abandonment of epidural or substitute for alternative method of analgesia
24 hours
Sensory block level < T10
大体时间:1 hour

Sensory block level to ice will be measured 1 hour after the loading dose is administered.

Yes: inadequate block No: adequate block

1 hour
Block height discrepancy
大体时间:24 hours

Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery.

Yes: inadequate block No: adequate block

24 hours
Re-siting of the epidural
大体时间:24 hours

Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:

  • Inadequate analgesia
  • Persistent unilateral block
  • Persistent intravascular placement
  • Extensive motor block
  • Hypotension
  • High block
24 hours
Adjustment of catheter length
大体时间:24 hours

Adjustment of catheter length at any time during labour would also indicate an inadequate block.

24 hours
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
大体时间:24 hours

The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist.

24 hours
Pain score >3 at any time during labour: questionnaire
大体时间:24 hours

A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

24 hours

次要结果测量

结果测量
措施说明
大体时间
Number of epidural top-ups administered by the nursing team
大体时间:24 hours

The number of times the labour and delivery nurse has to administer a top-up of the epidural.

24 hours
Number of epidural top-ups administered by the anesthesiologist
大体时间:24 hours

The number of times the anesthesiologist has to administer a top-up of the epidural.

24 hours
Pain scores recorded throughout labour: questionnaire
大体时间:24 hours

A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

24 hours
Hourly sensory block height assessment
大体时间:24 hours

Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice.

24 hours
Incidence of intravascular epidural placement
大体时间:24 hours

Any incidence of intravascular epidural placement during labour will be recorded.

24 hours
Incidence of catheter dislodgement
大体时间:24 hours

Any incidence of catheter dislodgement during labour will be recorded.

24 hours
Motor block using Bromage scale
大体时间:24 hours

Bromage scale will be recorded hourly as standard practice.

  • 3: Unable to move feet or knees
  • 2: Able to move feet only
  • 1: Able to just move knees
  • 0: Full flexion of knees and feet
24 hours
Presence of paresthesia on insertion.
大体时间:1 hour

Any presence of paresthesia on insertion will be recorded.

1 hour
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
大体时间:24 hours

Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist.

24 hours

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Mrinalini Balki, MD、MOUNT SINAI HOSPITAL

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2021年11月23日

初级完成 (实际的)

2024年7月26日

研究完成 (实际的)

2024年7月27日

研究注册日期

首次提交

2021年6月25日

首先提交符合 QC 标准的

2021年6月25日

首次发布 (实际的)

2021年6月30日

研究记录更新

最后更新发布 (实际的)

2026年11月17日

上次提交的符合 QC 标准的更新

2026年11月12日

最后验证

2025年3月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅