Optimale lengte van de katheter in de epidurale ruimte voor arbeidsanalgesie bij niet-zwaarlijvige vrouwen: een gerandomiseerde gecontroleerde proef van 4 cm versus 5 cm

Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.

Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.

Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.

This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.

Studie Overzicht

Toestand

Voltooid

Conditie

Interventie / Behandeling

Gedetailleerde beschrijving

Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.

Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.

The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

200

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Ontario
      • Toronto, Ontario, Canada, M5G1X5
        • Mount Sinai Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 50 jaar (Volwassen)

Accepteert gezonde vrijwilligers

Ja

Geslachten die in aanmerking komen voor studie

Vrouw

Beschrijving

Inclusion Criteria:

  • All women aged 18 years and above.
  • 3-7 cm dilation at time of insertion.
  • Women with BMI < 40 kg/m2

Exclusion Criteria:

  • Known contraindication to epidural insertion.
  • Inability or unwillingness to provide written consent.
  • Previous difficult epidural insertion.
  • Previous failed epidural.
  • Imminent instrumental or operative delivery.
  • Dural puncture.
  • Combined spinal epidural analgesia.
  • High BMI > 40 kg/m2

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Verdrievoudigen

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: 4 cm epidural catheter

The epidural catheter will be thread into the epidural space at a length of 4 cm.

The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

Andere namen:
  • ruggenprik
Actieve vergelijker: 5 cm epidural catheter

The epidural catheter will be thread into the epidural space at a length of 5 cm.

The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

Andere namen:
  • ruggenprik

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Composite outcome
Tijdsspanne: 24 hours

Presence of any of the individual primary outcomes described below:

  • Sensory block level <T10
  • VRNS pain score >3
  • Block height dicrepancy (unilateral or asymmetric block)
  • Re-siting of the epidural
  • Adjustment of catheter length
  • Abandonment of epidural or substitute for alternative method of analgesia
24 hours
Sensory block level < T10
Tijdsspanne: 1 hour

Sensory block level to ice will be measured 1 hour after the loading dose is administered.

Yes: inadequate block No: adequate block

1 hour
Block height discrepancy
Tijdsspanne: 24 hours

Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery.

Yes: inadequate block No: adequate block

24 hours
Re-siting of the epidural
Tijdsspanne: 24 hours

Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:

  • Inadequate analgesia
  • Persistent unilateral block
  • Persistent intravascular placement
  • Extensive motor block
  • Hypotension
  • High block
24 hours
Adjustment of catheter length
Tijdsspanne: 24 hours

Adjustment of catheter length at any time during labour would also indicate an inadequate block.

24 hours
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
Tijdsspanne: 24 hours

The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist.

24 hours
Pain score >3 at any time during labour: questionnaire
Tijdsspanne: 24 hours

A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

24 hours

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Number of epidural top-ups administered by the nursing team
Tijdsspanne: 24 hours

The number of times the labour and delivery nurse has to administer a top-up of the epidural.

24 hours
Number of epidural top-ups administered by the anesthesiologist
Tijdsspanne: 24 hours

The number of times the anesthesiologist has to administer a top-up of the epidural.

24 hours
Pain scores recorded throughout labour: questionnaire
Tijdsspanne: 24 hours

A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

24 hours
Hourly sensory block height assessment
Tijdsspanne: 24 hours

Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice.

24 hours
Incidence of intravascular epidural placement
Tijdsspanne: 24 hours

Any incidence of intravascular epidural placement during labour will be recorded.

24 hours
Incidence of catheter dislodgement
Tijdsspanne: 24 hours

Any incidence of catheter dislodgement during labour will be recorded.

24 hours
Motor block using Bromage scale
Tijdsspanne: 24 hours

Bromage scale will be recorded hourly as standard practice.

  • 3: Unable to move feet or knees
  • 2: Able to move feet only
  • 1: Able to just move knees
  • 0: Full flexion of knees and feet
24 hours
Presence of paresthesia on insertion.
Tijdsspanne: 1 hour

Any presence of paresthesia on insertion will be recorded.

1 hour
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
Tijdsspanne: 24 hours

Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist.

24 hours

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Mrinalini Balki, MD, MOUNT SINAI HOSPITAL

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

23 november 2021

Primaire voltooiing (Werkelijk)

26 juli 2024

Studie voltooiing (Werkelijk)

27 juli 2024

Studieregistratiedata

Eerst ingediend

25 juni 2021

Eerst ingediend dat voldeed aan de QC-criteria

25 juni 2021

Eerst geplaatst (Werkelijk)

30 juni 2021

Updates van studierecords

Laatste update geplaatst (Werkelijk)

17 november 2026

Laatste update ingediend die voldeed aan QC-criteria

12 november 2026

Laatst geverifieerd

1 maart 2025

Meer informatie

Termen gerelateerd aan deze studie

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren