Optymalna długość cewnika w przestrzeni zewnątrzoponowej do znieczulenia porodu u kobiet nieotyłych: randomizowana kontrolowana próba 4 cm w porównaniu z 5 cm
Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.
Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.
Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.
This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.
Przegląd badań
Szczegółowy opis
Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.
Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.
The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Ontario
-
Toronto, Ontario, Kanada, M5G1X5
- Mount Sinai Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- All women aged 18 years and above.
- 3-7 cm dilation at time of insertion.
- Women with BMI < 40 kg/m2
Exclusion Criteria:
- Known contraindication to epidural insertion.
- Inability or unwillingness to provide written consent.
- Previous difficult epidural insertion.
- Previous failed epidural.
- Imminent instrumental or operative delivery.
- Dural puncture.
- Combined spinal epidural analgesia.
- High BMI > 40 kg/m2
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Potroić
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: 4 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 4 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
Inne nazwy:
|
|
Aktywny komparator: 5 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 5 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Composite outcome
Ramy czasowe: 24 hours
|
Presence of any of the individual primary outcomes described below:
|
24 hours
|
|
Sensory block level < T10
Ramy czasowe: 1 hour
|
Sensory block level to ice will be measured 1 hour after the loading dose is administered. Yes: inadequate block No: adequate block |
1 hour
|
|
Block height discrepancy
Ramy czasowe: 24 hours
|
Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery. Yes: inadequate block No: adequate block |
24 hours
|
|
Re-siting of the epidural
Ramy czasowe: 24 hours
|
Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:
|
24 hours
|
|
Adjustment of catheter length
Ramy czasowe: 24 hours
|
Adjustment of catheter length at any time during labour would also indicate an inadequate block. |
24 hours
|
|
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
Ramy czasowe: 24 hours
|
The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist. |
24 hours
|
|
Pain score >3 at any time during labour: questionnaire
Ramy czasowe: 24 hours
|
A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of epidural top-ups administered by the nursing team
Ramy czasowe: 24 hours
|
The number of times the labour and delivery nurse has to administer a top-up of the epidural. |
24 hours
|
|
Number of epidural top-ups administered by the anesthesiologist
Ramy czasowe: 24 hours
|
The number of times the anesthesiologist has to administer a top-up of the epidural. |
24 hours
|
|
Pain scores recorded throughout labour: questionnaire
Ramy czasowe: 24 hours
|
A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
|
Hourly sensory block height assessment
Ramy czasowe: 24 hours
|
Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice. |
24 hours
|
|
Incidence of intravascular epidural placement
Ramy czasowe: 24 hours
|
Any incidence of intravascular epidural placement during labour will be recorded. |
24 hours
|
|
Incidence of catheter dislodgement
Ramy czasowe: 24 hours
|
Any incidence of catheter dislodgement during labour will be recorded. |
24 hours
|
|
Motor block using Bromage scale
Ramy czasowe: 24 hours
|
Bromage scale will be recorded hourly as standard practice.
|
24 hours
|
|
Presence of paresthesia on insertion.
Ramy czasowe: 1 hour
|
Any presence of paresthesia on insertion will be recorded. |
1 hour
|
|
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
Ramy czasowe: 24 hours
|
Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist. |
24 hours
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Mrinalini Balki, MD, MOUNT SINAI HOSPITAL
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 21-06
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .