- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT04946032
Lunghezza ottimale del catetere nello spazio epidurale per l'analgesia del travaglio in donne non obese: uno studio controllato randomizzato di 4 cm contro 5 cm
Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.
Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.
Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.
This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.
Panoramica dello studio
Descrizione dettagliata
Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.
Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.
The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Ontario
-
Toronto, Ontario, Canada, M5G1X5
- Mount Sinai Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- All women aged 18 years and above.
- 3-7 cm dilation at time of insertion.
- Women with BMI < 40 kg/m2
Exclusion Criteria:
- Known contraindication to epidural insertion.
- Inability or unwillingness to provide written consent.
- Previous difficult epidural insertion.
- Previous failed epidural.
- Imminent instrumental or operative delivery.
- Dural puncture.
- Combined spinal epidural analgesia.
- High BMI > 40 kg/m2
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Triplicare
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Comparatore attivo: 4 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 4 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
Altri nomi:
|
|
Comparatore attivo: 5 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 5 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Composite outcome
Lasso di tempo: 24 hours
|
Presence of any of the individual primary outcomes described below:
|
24 hours
|
|
Sensory block level < T10
Lasso di tempo: 1 hour
|
Sensory block level to ice will be measured 1 hour after the loading dose is administered. Yes: inadequate block No: adequate block |
1 hour
|
|
Block height discrepancy
Lasso di tempo: 24 hours
|
Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery. Yes: inadequate block No: adequate block |
24 hours
|
|
Re-siting of the epidural
Lasso di tempo: 24 hours
|
Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:
|
24 hours
|
|
Adjustment of catheter length
Lasso di tempo: 24 hours
|
Adjustment of catheter length at any time during labour would also indicate an inadequate block. |
24 hours
|
|
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
Lasso di tempo: 24 hours
|
The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist. |
24 hours
|
|
Pain score >3 at any time during labour: questionnaire
Lasso di tempo: 24 hours
|
A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Number of epidural top-ups administered by the nursing team
Lasso di tempo: 24 hours
|
The number of times the labour and delivery nurse has to administer a top-up of the epidural. |
24 hours
|
|
Number of epidural top-ups administered by the anesthesiologist
Lasso di tempo: 24 hours
|
The number of times the anesthesiologist has to administer a top-up of the epidural. |
24 hours
|
|
Pain scores recorded throughout labour: questionnaire
Lasso di tempo: 24 hours
|
A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
|
Hourly sensory block height assessment
Lasso di tempo: 24 hours
|
Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice. |
24 hours
|
|
Incidence of intravascular epidural placement
Lasso di tempo: 24 hours
|
Any incidence of intravascular epidural placement during labour will be recorded. |
24 hours
|
|
Incidence of catheter dislodgement
Lasso di tempo: 24 hours
|
Any incidence of catheter dislodgement during labour will be recorded. |
24 hours
|
|
Motor block using Bromage scale
Lasso di tempo: 24 hours
|
Bromage scale will be recorded hourly as standard practice.
|
24 hours
|
|
Presence of paresthesia on insertion.
Lasso di tempo: 1 hour
|
Any presence of paresthesia on insertion will be recorded. |
1 hour
|
|
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
Lasso di tempo: 24 hours
|
Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist. |
24 hours
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Mrinalini Balki, MD, MOUNT SINAI HOSPITAL
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 21-06
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .