- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT04083378
Software-Aided Imaging (Morfeus) voor het bevestigen van tumordekking met ablatie bij patiënten met levertumoren, de COVER-ALL-studie
Klinische impact van een volumetrische beeldmethode voor het bevestigen van tumordekking met ablatie bij patiënten met kwaadaardige leverlaesies (COVER-ALL)
This phase II trial studies how well software-aided imaging works in confirming tumor coverage with ablation (the removal or destruction of a body part or tissue or its function) on patients with liver tumors. The current standard for targeting tumor cells and evaluating the outcome of a liver ablation procedure is a visual inspection of the pre- and post-procedure computed tomography (CT) scans. Software-aided imaging systems, such as Morfeus, may help to improve the accuracy and effectiveness of liver ablation.
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
PRIMARY OBJECTIVE:
I. To evaluate if the intra-procedure feedback of a biomechanical deformable registration volumetric image method during percutaneous ablation will increase the minimal ablation margins on a three-dimensional computed tomography-generated analysis.
SECONDARY OBJECTIVES:
I. To assess whether applying the proposed method during percutaneous ablation improves local tumor progression-free survival (LTPFS) rates.
II. Evaluate impact of software use on procedure workflow.
III. Impact of software use on complication rates, quality of life, liver function.
IV. Evaluate oncological outcomes (intra-hepatic and overall progression-free survivals, and overall survival).
OUTLINE: Patients are randomized to 1 of 2 arms.
ARM I: Patients undergo standard of care ablation.
ARM II: Patients undergo standard of care ablation with software-aided imaging (Morfeus).
After completion of study, patients are followed up at 1, 3, and 6 months, and then at 1 and 2 years.
Studietype
Inschrijving (Werkelijk)
Fase
- Fase 2
Contacten en locaties
Studie Locaties
-
-
Texas
-
Houston, Texas, Verenigde Staten, 77030
- M D Anderson Cancer Center
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Patients presenting with ≤ 3 liver tumors (biopsy-proven or documented by imaging) measuring 1 to 5 cm planned to undergo percutaneous thermal ablation with either microwave or radiofrequency ablation. Patients with more than 3 tumors might also be eligible in case other tumors can be treated with another curative-intended loco-regional therapy (i.e. surgical resection, radiation therapy).
- Ability to completely cover the target tumor with at least a 5 mm ablation margin.
- Written informed consent to voluntarily participate in the study and follow-up CT scan schedule
- Age > 18 years-old
- Performance status 0-2 (Eastern Cooperative Oncology Group Classification [ECOG])
- Target tumor should be visualized on contrast-enhanced CT
- Adequate glomerular filtration rate
Exclusion Criteria
- Active bacterial infection or fungal infection on the day of the ablation that, in the opinion of the investigator, would interfere with safe delivery of the study procedure or with the interpretation of study results.
- Platelet < 50,000/mm3.
- INR > 1.5
- Patients with uncorrectable coagulopathy.
- Currently breastfeeding or pregnant (latter confirmed by serum pregnancy test).
- Physical or psychological condition which would impair study participation.
- ASA (American Society of Anesthesiologists) score of > 4.
- Any other loco-regional therapies at the target lesion(s) within 30 days of the ablation procedure.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Actieve vergelijker: Arm I (standard of care ablation)
Patients undergo standard of care ablation. |
Ancillary studies
Andere namen:
Ancillary studies Undergo standard of care ablation
Andere namen:
|
|
Experimenteel: Arm II (standard of care ablation, software-aided imaging)
Patients undergo standard of care ablation with software-aided imaging (Morfeus). |
Ancillary studies
Andere namen:
Ancillary studies Undergo standard of care ablation
Andere namen:
Undergo software-aided imaging (Morfeus)
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Minimal Ablative Margin Assessment on Post-ablation Intraprocedural CT.
Tijdsspanne: Visit 2 (baseline/ablation day)
|
For control group, MAM was assessed by rigid co-registration with side-by-side juxtaposition to verify applicator placement and by visual landmark-based CT measurements on CT workstation (Siemens Healthineers; Forchheim, Germany). For experimental group, CT images were processed with a software-based method on a radiation treatment planning system (Raystation, RaySearch Laboratories; Stockholm, Sweden) with biomechanical deformable imaging registration coupled with AI-based autosegmentation. For experimental group, interventional radiologist (IR) was informed of ablation applicator position relative to tumor on non-contrast CT before thermal ablation energy delivery and of MAM results (including spatial location of suboptimal margins) generated by software-based assessment, with this information not disclosed to IR in control group. Software-based assessment was used to compare MAMs results between both study groups with a two-sample t-test. |
Visit 2 (baseline/ablation day)
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Cumulative Incidence of 2-year Local Tumor Progression
Tijdsspanne: Time to local tumor progression (LTP) was measured from ablation to earliest LTP or death (competing event). Follow-up imaging continued up to 24 months.
|
A competing risk analysis was conducted to estimate the 2-year cumulative incidence of local tumor progression. Progression followed ablation reporting standards and RECIST v1.1 (mRECIST for HCC). |
Time to local tumor progression (LTP) was measured from ablation to earliest LTP or death (competing event). Follow-up imaging continued up to 24 months.
|
|
Overall Survival
Tijdsspanne: Overall survival was measured from the date of ablation to the date of death from any cause. Patients still alive were censored at the date of last clinic visit, with follow-up up to 24 months after ablation.
|
The Kaplan-Meier method was used to estimate overall survival |
Overall survival was measured from the date of ablation to the date of death from any cause. Patients still alive were censored at the date of last clinic visit, with follow-up up to 24 months after ablation.
|
|
Intrahepatic Progression-free Survival (for the Randomized Group)
Tijdsspanne: Up to 2 years
|
Competing risk analysis was conducted to estimate the 2-year intrahepatic (progression outside of ablation zone), considering the progression of the ablated tumor and treating death as a competing event. |
Up to 2 years
|
|
Extrahepatic Progression-free Survival
Tijdsspanne: Up to 2 years
|
Competing risk analysis was conducted to estimate the 2-year extrahepatic cumulative incidence of progression, considering the progression of the ablated tumor and treating death as a competing event. |
Up to 2 years
|
Medewerkers en onderzoekers
Sponsor
Medewerkers
Onderzoekers
- Hoofdonderzoeker: BRUNO C ODISIO, M.D. Anderson Cancer Center
Publicaties en nuttige links
Algemene publicaties
- Lin YM, Paolucci I, Anderson BM, O'Connor CS, Rigaud B, Briones-Dimayuga M, Jones KA, Brock KK, Fellman BM, Odisio BC. Study Protocol COVER-ALL: Clinical Impact of a Volumetric Image Method for Confirming Tumour Coverage with Ablation on Patients with Malignant Liver Lesions. Cardiovasc Intervent Radiol. 2022 Dec;45(12):1860-1867. doi: 10.1007/s00270-022-03255-3. Epub 2022 Sep 4.
- Odisio BC, Albuquerque J, Lin YM, Anderson BM, O'Connor CS, Rigaud B, Briones-Dimayuga M, Jones AK, Fellman BM, Huang SY, Kuban J, Metwalli ZA, Sheth R, Habibollahi P, Patel M, Shah KY, Cox VL, Kang HC, Morris VK, Kopetz S, Javle MM, Kaseb A, Tzeng CW, Cao HT, Newhook T, Chun YS, Vauthey JN, Gupta S, Paolucci I, Brock KK. Software-based versus visual assessment of the minimal ablative margin in patients with liver tumours undergoing percutaneous thermal ablation (COVER-ALL): a randomised phase 2 trial. Lancet Gastroenterol Hepatol. 2025 May;10(5):442-451. doi: 10.1016/S2468-1253(25)00024-X. Epub 2025 Mar 13.
- Siddiqi NS, Albuquerque J, Paolucci I, Lin YM, O'Connor C, Haddad A, Jones AK, Vauthey JN, Brock KK, Odisio BC. Quantifying Functional Liver Volume Loss after CT-guided Percutaneous Thermal Ablation: A COVER-ALL Trial Post Hoc Analysis. Radiol Imaging Cancer. 2026 Mar;8(2):e250385. doi: 10.1148/rycan.250385.
Nuttige links
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 2019-0213
- 2019-0213 (Andere identificatie: M D Anderson Cancer Center)
- NCI-2019-05762 (Register-ID: CTRP (Clinical Trial Reporting Program))
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .