- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT05812040
Klinische waarde van MR-ductografie met hoge resolutie van de borst bij patiënten met pathologische tepelafscheiding
Klinische waarde van MR-ductografie met hoge resolutie in de borst bij patiënten met pathologische tepelafscheiding: een prospectief, verkennend diagnostisch onderzoek
Nipple discharge is one of the common symptoms of breast disease patients. Nipple discharge can be divided into physiological and pathological nipple discharge (PND). Among patients with PND symptoms who undergo biopsy, 5%-21% of them are malignant, and the risk of malignancy increases with age. The primary diagnostic imaging methods for PND patients include mammography and breast ultrasound. Nearly half of PND patients who undergo traditional mammography and ultrasound examination have negative findings, but this does not rule out the presence of malignant lesions. Central duct excision is the gold standard for PND diagnosis, but invasive surgery without imaging guidance can lead to some complications. Magnetic Resonance Ductography (MRD), which uses water imaging technology to visualize the inside of the duct without contrast injection, can show imaging features of ductal lesions such as filling defects, irregularities of duct walls, and ductal obstruction. However, previous studies have shown that the signal-to-noise ratio of MRD images needs to be improved. Microscopy coil has the characteristics of small voxels and high spatial resolution, making it suitable for high signal-to-noise ratio imaging of small superficial structures. This provides a hardware foundation for improving the quality of MRD images. Therefore, in this study, the investigators aim to use the 3T MR instrument and microscopy coil to perform non-invasive high-resolution Magnetic Resonance Ductography (HR-MRD) on PND patients to evaluate the ability of HR-MRD to detect PND causes and the imaging features of duct-related lesions on HR-MRD, to assist in the accurate diagnosis and treatment of PND.
Studie Overzicht
Toestand
Conditie
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
Guangdong
-
Guangzhou, Guangdong, China, 510120
- Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Female patients aged between 18 and 75 years old.
- Pathological nipple discharge patients who received treatment at Sun Yat-sen Memorial Hospital. The diagnostic criteria for pathological nipple discharge include unilateral, single duct orifice, and spontaneous discharge of serous or bloody fluid. Patients who meet any of the above criteria are considered as pathological discharge.
- Willing to sign an informed consent form for clinical research and undergo HR-MRD and MRD examination.
Exclusion Criteria:
- Patients who have undergone surgery on the nipple-areolar complex of the PND breast side within the past year.
- Patients who have claustrophobia or metal implants in their body, which are not suitable for MRI scans.
- Patients who are pregnant or breastfeeding.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Diagnostisch
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Ander: MRD + HR-MRD
|
all participants will receive Magnetic Resonance Ductography (MRD) and High-Resolution Magnetic Resonance Ductography (HR-MRD) examination, using breast dedicated coil and microscopic coil, respectively |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Analyseer de gevoeligheid en specificiteit van HR-MRD bij het detecteren van laesies die chirurgische excisie vereisen bij patiënten met PND
Tijdsspanne: 15 maanden
|
15 maanden
|
Secundaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Analyseer de PPV en NPV van HR-MRD bij het detecteren van laesies die chirurgische excisie vereisen bij patiënten met PND
Tijdsspanne: 15 maanden
|
15 maanden
|
|
Het verschil in detectiegevoeligheid tussen HR-MRD en MRD bij het identificeren van laesies die chirurgische excisie vereisen
Tijdsspanne: 15 maanden
|
15 maanden
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Yue Hu, MD., Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University
Publicaties en nuttige links
Algemene publicaties
- Seltzer MH, Perloff LJ, Kelley RI, Fitts WT Jr. The significance of age in patients with nipple discharge. Surg Gynecol Obstet. 1970 Sep;131(3):519-22. No abstract available.
- Orel SG, Dougherty CS, Reynolds C, Czerniecki BJ, Siegelman ES, Schnall MD. MR imaging in patients with nipple discharge: initial experience. Radiology. 2000 Jul;216(1):248-54. doi: 10.1148/radiology.216.1.r00jn28248.
- Kanemaki Y, Kurihara Y, Itoh D, Kamijo K, Nakajima Y, Fukuda M, Van Cauteren M. MR mammary ductography using a microscopy coil for assessment of intraductal lesions. AJR Am J Roentgenol. 2004 May;182(5):1340-2. doi: 10.2214/ajr.182.5.1821340. No abstract available.
- Bhattarai N, Kanemaki Y, Kurihara Y, Nakajima Y, Fukuda M, Maeda I. Intraductal papilloma: features on MR ductography using a microscopic coil. AJR Am J Roentgenol. 2006 Jan;186(1):44-7. doi: 10.2214/AJR.04.1600.
- Fu P, Kurihara Y, Kanemaki Y, Okamoto K, Nakajima Y, Fukuda M, Maeda I. High-resolution MRI in detecting subareolar breast abscess. AJR Am J Roentgenol. 2007 Jun;188(6):1568-72. doi: 10.2214/AJR.06.0099.
- Hirose M, Nobusawa H, Gokan T. MR ductography: comparison with conventional ductography as a diagnostic method in patients with nipple discharge. Radiographics. 2007 Oct;27 Suppl 1:S183-96. doi: 10.1148/rg.27si075501.
- Kanemaki Y, Kurihara Y, Okamoto K, Nakajima Y, Fukuda M, Maeda I, Akiyama F. Ductal carcinoma in situ: correlations between high-resolution magnetic resonance imaging and histopathology. Radiat Med. 2007 Jan;25(1):1-7. doi: 10.1007/s11604-006-0091-5. Epub 2007 Jan 25.
- Zhu J, Kurihara Y, Kanemaki Y, Ogata H, Fukuda M, Nakajima Y, Maeda I. Diagnostic accuracy of high-resolution MRI using a microscopy coil for patients with presumed DCIS following mammography screening. J Magn Reson Imaging. 2007 Jan;25(1):96-103. doi: 10.1002/jmri.20809.
- Bahl M, Baker JA, Greenup RA, Ghate SV. Evaluation of Pathologic Nipple Discharge: What is the Added Diagnostic Value of MRI? Ann Surg Oncol. 2015 Dec;22 Suppl 3:S435-41. doi: 10.1245/s10434-015-4792-9. Epub 2015 Aug 7.
- Mann RM, Balleyguier C, Baltzer PA, Bick U, Colin C, Cornford E, Evans A, Fallenberg E, Forrai G, Fuchsjager MH, Gilbert FJ, Helbich TH, Heywang-Kobrunner SH, Camps-Herrero J, Kuhl CK, Martincich L, Pediconi F, Panizza P, Pina LJ, Pijnappel RM, Pinker-Domenig K, Skaane P, Sardanelli F; European Society of Breast Imaging (EUSOBI), with language review by Europa Donna-The European Breast Cancer Coalition. Breast MRI: EUSOBI recommendations for women's information. Eur Radiol. 2015 Dec;25(12):3669-78. doi: 10.1007/s00330-015-3807-z. Epub 2015 May 23.
- Nicholson BT, Harvey JA, Patrie JT, Mugler JP 3rd. 3D-MR Ductography and Contrast-Enhanced MR Mammography in Patients with Suspicious Nipple Discharge; a Feasibility Study. Breast J. 2015 Jul-Aug;21(4):352-62. doi: 10.1111/tbj.12417. Epub 2015 Apr 16.
- Berger N, Luparia A, Di Leo G, Carbonaro LA, Trimboli RM, Ambrogi F, Sardanelli F. Diagnostic Performance of MRI Versus Galactography in Women With Pathologic Nipple Discharge: A Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2017 Aug;209(2):465-471. doi: 10.2214/AJR.16.16682. Epub 2017 May 24.
- Expert Panel on Breast Imaging:; Lee SJ, Trikha S, Moy L, Baron P, diFlorio RM, Green ED, Heller SL, Holbrook AI, Lewin AA, Lourenco AP, Niell BL, Slanetz PJ, Stuckey AR, Vincoff NS, Weinstein SP, Yepes MM, Newell MS. ACR Appropriateness Criteria(R) Evaluation of Nipple Discharge. J Am Coll Radiol. 2017 May;14(5S):S138-S153. doi: 10.1016/j.jacr.2017.01.030.
- Gupta D, Mendelson EB, Karst I. Nipple Discharge: Current Clinical and Imaging Evaluation. AJR Am J Roentgenol. 2021 Feb;216(2):330-339. doi: 10.2214/AJR.19.22025. Epub 2020 Dec 9.
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- SYSKY-2023-122-02
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .