- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT05812040
Клиническое значение МР-дуктографии высокого разрешения молочной железы у пациентов с патологическими выделениями из сосков
Клиническая ценность МР-дуктографии молочной железы высокого разрешения у пациентов с патологическими выделениями из сосков: проспективное исследовательское диагностическое исследование
Nipple discharge is one of the common symptoms of breast disease patients. Nipple discharge can be divided into physiological and pathological nipple discharge (PND). Among patients with PND symptoms who undergo biopsy, 5%-21% of them are malignant, and the risk of malignancy increases with age. The primary diagnostic imaging methods for PND patients include mammography and breast ultrasound. Nearly half of PND patients who undergo traditional mammography and ultrasound examination have negative findings, but this does not rule out the presence of malignant lesions. Central duct excision is the gold standard for PND diagnosis, but invasive surgery without imaging guidance can lead to some complications. Magnetic Resonance Ductography (MRD), which uses water imaging technology to visualize the inside of the duct without contrast injection, can show imaging features of ductal lesions such as filling defects, irregularities of duct walls, and ductal obstruction. However, previous studies have shown that the signal-to-noise ratio of MRD images needs to be improved. Microscopy coil has the characteristics of small voxels and high spatial resolution, making it suitable for high signal-to-noise ratio imaging of small superficial structures. This provides a hardware foundation for improving the quality of MRD images. Therefore, in this study, the investigators aim to use the 3T MR instrument and microscopy coil to perform non-invasive high-resolution Magnetic Resonance Ductography (HR-MRD) on PND patients to evaluate the ability of HR-MRD to detect PND causes and the imaging features of duct-related lesions on HR-MRD, to assist in the accurate diagnosis and treatment of PND.
Обзор исследования
Статус
Тип исследования
Регистрация (Действительный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Guangdong
-
Guangzhou, Guangdong, Китай, 510120
- Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- Female patients aged between 18 and 75 years old.
- Pathological nipple discharge patients who received treatment at Sun Yat-sen Memorial Hospital. The diagnostic criteria for pathological nipple discharge include unilateral, single duct orifice, and spontaneous discharge of serous or bloody fluid. Patients who meet any of the above criteria are considered as pathological discharge.
- Willing to sign an informed consent form for clinical research and undergo HR-MRD and MRD examination.
Exclusion Criteria:
- Patients who have undergone surgery on the nipple-areolar complex of the PND breast side within the past year.
- Patients who have claustrophobia or metal implants in their body, which are not suitable for MRI scans.
- Patients who are pregnant or breastfeeding.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Диагностика
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Другой: MRD + HR-MRD
|
all participants will receive Magnetic Resonance Ductography (MRD) and High-Resolution Magnetic Resonance Ductography (HR-MRD) examination, using breast dedicated coil and microscopic coil, respectively |
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
Анализ чувствительности и специфичности HR-MRD при обнаружении поражений, требующих хирургического удаления, у пациентов с ПНД.
Временное ограничение: 15 месяцев
|
15 месяцев
|
Вторичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
Анализ PPV и NPV HR-MRD при обнаружении поражений, требующих хирургического удаления, у пациентов с PND.
Временное ограничение: 15 месяцев
|
15 месяцев
|
|
Разница в чувствительности обнаружения между HR-MRD и MRD при выявлении поражений, требующих хирургического удаления
Временное ограничение: 15 месяцев
|
15 месяцев
|
Соавторы и исследователи
Следователи
- Главный следователь: Yue Hu, MD., Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University
Публикации и полезные ссылки
Общие публикации
- Seltzer MH, Perloff LJ, Kelley RI, Fitts WT Jr. The significance of age in patients with nipple discharge. Surg Gynecol Obstet. 1970 Sep;131(3):519-22. No abstract available.
- Orel SG, Dougherty CS, Reynolds C, Czerniecki BJ, Siegelman ES, Schnall MD. MR imaging in patients with nipple discharge: initial experience. Radiology. 2000 Jul;216(1):248-54. doi: 10.1148/radiology.216.1.r00jn28248.
- Kanemaki Y, Kurihara Y, Itoh D, Kamijo K, Nakajima Y, Fukuda M, Van Cauteren M. MR mammary ductography using a microscopy coil for assessment of intraductal lesions. AJR Am J Roentgenol. 2004 May;182(5):1340-2. doi: 10.2214/ajr.182.5.1821340. No abstract available.
- Bhattarai N, Kanemaki Y, Kurihara Y, Nakajima Y, Fukuda M, Maeda I. Intraductal papilloma: features on MR ductography using a microscopic coil. AJR Am J Roentgenol. 2006 Jan;186(1):44-7. doi: 10.2214/AJR.04.1600.
- Fu P, Kurihara Y, Kanemaki Y, Okamoto K, Nakajima Y, Fukuda M, Maeda I. High-resolution MRI in detecting subareolar breast abscess. AJR Am J Roentgenol. 2007 Jun;188(6):1568-72. doi: 10.2214/AJR.06.0099.
- Hirose M, Nobusawa H, Gokan T. MR ductography: comparison with conventional ductography as a diagnostic method in patients with nipple discharge. Radiographics. 2007 Oct;27 Suppl 1:S183-96. doi: 10.1148/rg.27si075501.
- Kanemaki Y, Kurihara Y, Okamoto K, Nakajima Y, Fukuda M, Maeda I, Akiyama F. Ductal carcinoma in situ: correlations between high-resolution magnetic resonance imaging and histopathology. Radiat Med. 2007 Jan;25(1):1-7. doi: 10.1007/s11604-006-0091-5. Epub 2007 Jan 25.
- Zhu J, Kurihara Y, Kanemaki Y, Ogata H, Fukuda M, Nakajima Y, Maeda I. Diagnostic accuracy of high-resolution MRI using a microscopy coil for patients with presumed DCIS following mammography screening. J Magn Reson Imaging. 2007 Jan;25(1):96-103. doi: 10.1002/jmri.20809.
- Bahl M, Baker JA, Greenup RA, Ghate SV. Evaluation of Pathologic Nipple Discharge: What is the Added Diagnostic Value of MRI? Ann Surg Oncol. 2015 Dec;22 Suppl 3:S435-41. doi: 10.1245/s10434-015-4792-9. Epub 2015 Aug 7.
- Mann RM, Balleyguier C, Baltzer PA, Bick U, Colin C, Cornford E, Evans A, Fallenberg E, Forrai G, Fuchsjager MH, Gilbert FJ, Helbich TH, Heywang-Kobrunner SH, Camps-Herrero J, Kuhl CK, Martincich L, Pediconi F, Panizza P, Pina LJ, Pijnappel RM, Pinker-Domenig K, Skaane P, Sardanelli F; European Society of Breast Imaging (EUSOBI), with language review by Europa Donna-The European Breast Cancer Coalition. Breast MRI: EUSOBI recommendations for women's information. Eur Radiol. 2015 Dec;25(12):3669-78. doi: 10.1007/s00330-015-3807-z. Epub 2015 May 23.
- Nicholson BT, Harvey JA, Patrie JT, Mugler JP 3rd. 3D-MR Ductography and Contrast-Enhanced MR Mammography in Patients with Suspicious Nipple Discharge; a Feasibility Study. Breast J. 2015 Jul-Aug;21(4):352-62. doi: 10.1111/tbj.12417. Epub 2015 Apr 16.
- Berger N, Luparia A, Di Leo G, Carbonaro LA, Trimboli RM, Ambrogi F, Sardanelli F. Diagnostic Performance of MRI Versus Galactography in Women With Pathologic Nipple Discharge: A Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2017 Aug;209(2):465-471. doi: 10.2214/AJR.16.16682. Epub 2017 May 24.
- Expert Panel on Breast Imaging:; Lee SJ, Trikha S, Moy L, Baron P, diFlorio RM, Green ED, Heller SL, Holbrook AI, Lewin AA, Lourenco AP, Niell BL, Slanetz PJ, Stuckey AR, Vincoff NS, Weinstein SP, Yepes MM, Newell MS. ACR Appropriateness Criteria(R) Evaluation of Nipple Discharge. J Am Coll Radiol. 2017 May;14(5S):S138-S153. doi: 10.1016/j.jacr.2017.01.030.
- Gupta D, Mendelson EB, Karst I. Nipple Discharge: Current Clinical and Imaging Evaluation. AJR Am J Roentgenol. 2021 Feb;216(2):330-339. doi: 10.2214/AJR.19.22025. Epub 2020 Dec 9.
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
- Урогенитальные заболевания
- Новообразования по локализации
- Новообразования
- Женские мочеполовые заболевания и осложнения беременности
- Осложнения беременности
- Кожные заболевания
- Заболевания груди
- Послеродовые расстройства
- Нарушения лактации
- Заболевания кожи и соединительной ткани
- Новообразования молочной железы
- Галакторея
Другие идентификационные номера исследования
- SYSKY-2023-122-02
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .