- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT05812040
Wartość kliniczna duktografii MR piersi o wysokiej rozdzielczości u pacjentek z patologicznym wyciekiem z brodawki sutkowej
Wartość kliniczna duktografii MR piersi o wysokiej rozdzielczości u pacjentek z patologicznym wyciekiem z brodawki sutkowej: prospektywne, eksploracyjne badanie diagnostyczne
Nipple discharge is one of the common symptoms of breast disease patients. Nipple discharge can be divided into physiological and pathological nipple discharge (PND). Among patients with PND symptoms who undergo biopsy, 5%-21% of them are malignant, and the risk of malignancy increases with age. The primary diagnostic imaging methods for PND patients include mammography and breast ultrasound. Nearly half of PND patients who undergo traditional mammography and ultrasound examination have negative findings, but this does not rule out the presence of malignant lesions. Central duct excision is the gold standard for PND diagnosis, but invasive surgery without imaging guidance can lead to some complications. Magnetic Resonance Ductography (MRD), which uses water imaging technology to visualize the inside of the duct without contrast injection, can show imaging features of ductal lesions such as filling defects, irregularities of duct walls, and ductal obstruction. However, previous studies have shown that the signal-to-noise ratio of MRD images needs to be improved. Microscopy coil has the characteristics of small voxels and high spatial resolution, making it suitable for high signal-to-noise ratio imaging of small superficial structures. This provides a hardware foundation for improving the quality of MRD images. Therefore, in this study, the investigators aim to use the 3T MR instrument and microscopy coil to perform non-invasive high-resolution Magnetic Resonance Ductography (HR-MRD) on PND patients to evaluate the ability of HR-MRD to detect PND causes and the imaging features of duct-related lesions on HR-MRD, to assist in the accurate diagnosis and treatment of PND.
Przegląd badań
Status
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Guangdong
-
Guangzhou, Guangdong, Chiny, 510120
- Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Female patients aged between 18 and 75 years old.
- Pathological nipple discharge patients who received treatment at Sun Yat-sen Memorial Hospital. The diagnostic criteria for pathological nipple discharge include unilateral, single duct orifice, and spontaneous discharge of serous or bloody fluid. Patients who meet any of the above criteria are considered as pathological discharge.
- Willing to sign an informed consent form for clinical research and undergo HR-MRD and MRD examination.
Exclusion Criteria:
- Patients who have undergone surgery on the nipple-areolar complex of the PND breast side within the past year.
- Patients who have claustrophobia or metal implants in their body, which are not suitable for MRI scans.
- Patients who are pregnant or breastfeeding.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Diagnostyczny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Inny: MRD + HR-MRD
|
all participants will receive Magnetic Resonance Ductography (MRD) and High-Resolution Magnetic Resonance Ductography (HR-MRD) examination, using breast dedicated coil and microscopic coil, respectively |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Ramy czasowe |
|---|---|
|
Analiza czułości i swoistości HR-MRD w wykrywaniu zmian wymagających wycięcia chirurgicznego u pacjentów z PND
Ramy czasowe: 15 miesięcy
|
15 miesięcy
|
Miary wyników drugorzędnych
Miara wyniku |
Ramy czasowe |
|---|---|
|
Analiza PPV i NPV HR-MRD w wykrywaniu zmian wymagających wycięcia chirurgicznego u pacjentów z PND
Ramy czasowe: 15 miesięcy
|
15 miesięcy
|
|
Różnica w czułości wykrywania HR-MRD i MRD w identyfikacji zmian wymagających wycięcia chirurgicznego
Ramy czasowe: 15 miesięcy
|
15 miesięcy
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Yue Hu, MD., Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University
Publikacje i pomocne linki
Publikacje ogólne
- Seltzer MH, Perloff LJ, Kelley RI, Fitts WT Jr. The significance of age in patients with nipple discharge. Surg Gynecol Obstet. 1970 Sep;131(3):519-22. No abstract available.
- Orel SG, Dougherty CS, Reynolds C, Czerniecki BJ, Siegelman ES, Schnall MD. MR imaging in patients with nipple discharge: initial experience. Radiology. 2000 Jul;216(1):248-54. doi: 10.1148/radiology.216.1.r00jn28248.
- Kanemaki Y, Kurihara Y, Itoh D, Kamijo K, Nakajima Y, Fukuda M, Van Cauteren M. MR mammary ductography using a microscopy coil for assessment of intraductal lesions. AJR Am J Roentgenol. 2004 May;182(5):1340-2. doi: 10.2214/ajr.182.5.1821340. No abstract available.
- Bhattarai N, Kanemaki Y, Kurihara Y, Nakajima Y, Fukuda M, Maeda I. Intraductal papilloma: features on MR ductography using a microscopic coil. AJR Am J Roentgenol. 2006 Jan;186(1):44-7. doi: 10.2214/AJR.04.1600.
- Fu P, Kurihara Y, Kanemaki Y, Okamoto K, Nakajima Y, Fukuda M, Maeda I. High-resolution MRI in detecting subareolar breast abscess. AJR Am J Roentgenol. 2007 Jun;188(6):1568-72. doi: 10.2214/AJR.06.0099.
- Hirose M, Nobusawa H, Gokan T. MR ductography: comparison with conventional ductography as a diagnostic method in patients with nipple discharge. Radiographics. 2007 Oct;27 Suppl 1:S183-96. doi: 10.1148/rg.27si075501.
- Kanemaki Y, Kurihara Y, Okamoto K, Nakajima Y, Fukuda M, Maeda I, Akiyama F. Ductal carcinoma in situ: correlations between high-resolution magnetic resonance imaging and histopathology. Radiat Med. 2007 Jan;25(1):1-7. doi: 10.1007/s11604-006-0091-5. Epub 2007 Jan 25.
- Zhu J, Kurihara Y, Kanemaki Y, Ogata H, Fukuda M, Nakajima Y, Maeda I. Diagnostic accuracy of high-resolution MRI using a microscopy coil for patients with presumed DCIS following mammography screening. J Magn Reson Imaging. 2007 Jan;25(1):96-103. doi: 10.1002/jmri.20809.
- Bahl M, Baker JA, Greenup RA, Ghate SV. Evaluation of Pathologic Nipple Discharge: What is the Added Diagnostic Value of MRI? Ann Surg Oncol. 2015 Dec;22 Suppl 3:S435-41. doi: 10.1245/s10434-015-4792-9. Epub 2015 Aug 7.
- Mann RM, Balleyguier C, Baltzer PA, Bick U, Colin C, Cornford E, Evans A, Fallenberg E, Forrai G, Fuchsjager MH, Gilbert FJ, Helbich TH, Heywang-Kobrunner SH, Camps-Herrero J, Kuhl CK, Martincich L, Pediconi F, Panizza P, Pina LJ, Pijnappel RM, Pinker-Domenig K, Skaane P, Sardanelli F; European Society of Breast Imaging (EUSOBI), with language review by Europa Donna-The European Breast Cancer Coalition. Breast MRI: EUSOBI recommendations for women's information. Eur Radiol. 2015 Dec;25(12):3669-78. doi: 10.1007/s00330-015-3807-z. Epub 2015 May 23.
- Nicholson BT, Harvey JA, Patrie JT, Mugler JP 3rd. 3D-MR Ductography and Contrast-Enhanced MR Mammography in Patients with Suspicious Nipple Discharge; a Feasibility Study. Breast J. 2015 Jul-Aug;21(4):352-62. doi: 10.1111/tbj.12417. Epub 2015 Apr 16.
- Berger N, Luparia A, Di Leo G, Carbonaro LA, Trimboli RM, Ambrogi F, Sardanelli F. Diagnostic Performance of MRI Versus Galactography in Women With Pathologic Nipple Discharge: A Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2017 Aug;209(2):465-471. doi: 10.2214/AJR.16.16682. Epub 2017 May 24.
- Expert Panel on Breast Imaging:; Lee SJ, Trikha S, Moy L, Baron P, diFlorio RM, Green ED, Heller SL, Holbrook AI, Lewin AA, Lourenco AP, Niell BL, Slanetz PJ, Stuckey AR, Vincoff NS, Weinstein SP, Yepes MM, Newell MS. ACR Appropriateness Criteria(R) Evaluation of Nipple Discharge. J Am Coll Radiol. 2017 May;14(5S):S138-S153. doi: 10.1016/j.jacr.2017.01.030.
- Gupta D, Mendelson EB, Karst I. Nipple Discharge: Current Clinical and Imaging Evaluation. AJR Am J Roentgenol. 2021 Feb;216(2):330-339. doi: 10.2214/AJR.19.22025. Epub 2020 Dec 9.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- SYSKY-2023-122-02
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .