- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT06436222
Effectiviteit van HVNI bij premature baby's met matige ademhalingsproblemen
Effectiveness of High Velocity Nasal Insufflation (HVNI) in Infants With Respiratory Distress at Dr.Cipto Mangunkusumo Hospital
Neonatal respiratory distress is a common problem in preterm infants. The application of CPAP is widely used in neonatal units as a primary mode of respiratory support for respiratory distress. However, discomfort, nasal injuries, and fixation difficulties have been reported as obstacles when applying CPAP. High velocity nasal insufflation (HVNI) may serve as an alternative to CPAP. Trials are needed to evaluate the effectiveness of HVNI in reducing the incidence of respiratory distress. The aim of this study is to compare the clinical effectiveness and safety of HVNI as an alternative therapy to CPAP in premature infants with moderate respiratory distress.
This study was originally designed as a non-inferiority randomized controlled trial. Due to feasibility constraints, the protocol was amended prior to completion of recruitment, and the study was reclassified as a pilot randomized controlled trial to assess feasibility and safety outcomes of HVNI compared to CPAP. The subjects were randomly allocated to receive either HVNI or CPAP according to the study protocol. They were randomly assigned using blocks of four. The completion of HVNI therapy was determined by therapeutic failure within 72 hours following enrollment, indicated by the need for intubation.
Studie Overzicht
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
DKI Jakarta
-
Jakarta Pusat, DKI Jakarta, Indonesië
- Cipto Mangunkusumo General Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
**Inclusion Criteria:**
- Preterm infants born in Cipto Mangunkusumo Hospital with gestational age (GA) less than 32 weeks or birth weight less than 1500 grams.
- Infants with moderate respiratory distress (Downe score ≤ 6) detected within 24 hours after birth.
- Parents are willing to participate in the study.
**Exclusion Criteria:**
- Infants with severe respiratory distress (Downe score ≥ 6) requiring invasive treatment in the form of mechanical ventilation, or apnea indicated by surfactant administration via endotracheal tube.
- Infants with contraindications to the use of non-invasive ventilation such as esophageal atresia, diaphragmatic hernia, air leak syndrome, and other conditions.
- Infants with respiratory distress due to non-pulmonary abnormalities.
- Infants with congenital metabolic disorders.
- Infants with congenital abnormalities that exacerbate respiratory distress.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ondersteunende zorg
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Ander: HVNI (Intervention Group)
The infant was given therapy using HVNI with an initial flow of 6 L/min. Inspiratory fraction of oxygen (FiO2) started with 30% following the SpO2 target. The maximum flow is 8L/min. FiO2 can be increased by 5% until the target SpO2 is reached. |
The infant was given therapy using HVNI with an initial flow of 6 L/min. Inspiratory fraction of oxygen (FiO2) started with 30% following the SpO2 target. The maximum flow is 8L/min. FiO2 can be increased by 5% until the target SpO2 is reached. |
|
Ander: CPAP(Control Group)
The infant was given therapy using CPAP with an initial pressure of 7 cmH20. Inspiratory fraction of oxygen (FiO2) starting with 30% following the SpO2 target.The maximum of CPAP pressure is 8 cmH2O. FiO2 can be increased by 5% until the target SpO2 is reached. |
The infant was given therapy using HVNI with an initial flow of 6 L/min. Inspiratory fraction of oxygen (FiO2) started with 30% following the SpO2 target. The maximum flow is 8L/min. FiO2 can be increased by 5% until the target SpO2 is reached. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Effectiveness of HVNI to prevent intubation within 72 hours
Tijdsspanne: Intubation rates within 72 hours
|
The primary outcome was treatment failure/success within 72 hours of treatment between HVNI and CPAP |
Intubation rates within 72 hours
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Length of stay
Tijdsspanne: 30 days
|
Duration from birth until discharge |
30 days
|
Andere uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Intraventricular Hemmorhage (IVH)
Tijdsspanne: one week
|
The occurrence of bleeding in lateral and third or fourth ventricles characterized by hyper-attenuating fluid typically seen as layering within the ventricles in imaging studies |
one week
|
|
Bronchopulmonary Dysplasia (BPD)
Tijdsspanne: Within 28 days
|
Prolonged need for supplemental oxygen in preterm infants after 28 days of age or after 36 weeks postmenstrual age and who do not have other conditions requiring oxygen |
Within 28 days
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 336/UN2.F1/ETIK/PPM.00.02/2024
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .