Impact van kunstmatige intelligentie op het aantal gemiste poliepen bij stagiaires

23 september 2026 bijgewerkt door: Northwestern University

Impact van computerondersteunde detectie op het aantal gemiste poliepen bij stagiaires met behulp van een tandem-coloscopie-ontwerp

Based on prior studies, trainee and practicing gastroenterologists miss pre-cancerous polyps (adenomas and serrated polyps) during colonoscopy. The use of computer-aided detection (CADe) systems, a form of artificial intelligence (AI) has been shown to help identify colorectal lesions for practicing gastroenterologists. However, less is known how AI impacts polyp detection for trainees.

The investigators are conducting a tandem colonoscopy study wherein a portion of the colon is examined first by the trainee and then the attending physician. For each procedure, randomization will occur which will determine whether or not the trainee will utilize AI for their examination of the colon. At the end of the study, the investigators will determine whether AI helps trainees miss fewer polyps during colonoscopy. The investigators will also conduct interviews with trainees to understand how AI impacts colonoscopy training.

Studie Overzicht

Gedetailleerde beschrijving

Quality metrics in colonoscopy are useful in determining endoscopist performance. The adenoma detection rate (ADR) has historically been the primary colonoscopy quality indicator of interest, whereby those with a higher ADR have lower rates of interval colon cancers. Other important parameters include the adenoma miss rate (AMR) and the sessile serrated polyp miss rate (SMR).

The AMR among practicing gastroenterologists is estimated at around 25% based on tandem-colonoscopy studies, while the SMR may be even higher. Prior tandem colonoscopy studies have also shown that gastroenterology trainees have an AMR between 30-41% and an SMR between 56-86%. As missed polyps may grow into colorectal cancers over time, efforts must be dedicated to reducing AMR and SMR.

In 2021, the Food and Drug Administration (FDA) approved the first computer-aided detection (CADe) system, (GI-Genius; Medtronic, Minneapolis, MN) for identifying colorectal lesions in the United States. An initial tandem colonoscopy study among experienced endoscopists using this CADe system showed a reduction in AMR from 32.4% to 15.5%. However, it is unknown whether trainees would have a similar reduction in polyp miss rates.

CADe has been introduced into gastroenterology trainee education in a largely unstructured fashion and trainees' perception of CADe's impact on training is largely unknown. Presently, trainees and attendings complete colonoscopies with and without CADe. It is at the discretion of attendings whether CADe is used for a procedure regardless of whether or not a trainee is involved.

In this single center study, all Northwestern gastroenterology trainees will be invited to participate in the trial. First year gastroenterology trainees will initiate participation after 6 months of endoscopic training (approximately 100 colonoscopies completed). Trainees will be complete an hour-long meeting with the study team. The study protocol will be explained in detail and written informed consent will be obtained from the trainees.

The medical records of patients scheduled for ambulatory screening or surveillance colonoscopy during select endoscopy blocks will be screened in advance for inclusion in the study. Participants will be prospectively enrolled.

On the day of the patient's scheduled colonoscopy, a member of the study team will obtain written informed consent for both the colonoscopy and participation in the research study in a private bay in the pre-endoscopy area. The patient will then be transported to the procedure room and sedated. Sedation method (monitored anesthesia care or moderate sedation) will be determined prior to the scheduled appointment. If the patient is to receive moderate sedation, fentanyl and midazolam will be administered in incremental doses per the standard of care. Once the patient is sedated, the fellow and attending will perform the insertion as is standard for a colonoscopy in which a fellow is participating. Once the cecum is reached, the patient will then be randomized to whether the initial inspection of the right colon by the fellow is performed with or without the assistance of CADe in a 1:1 randomization. The fellow withdrawal (pass #1) will start. The fellow, with or without the use of CADe based on randomization, will identify polyps independently of the attending and remove them with attending assistance as appropriate until they feel that they have performed a complete examination of colonic mucosa from the cecum to the splenic flexure. During pass #1, the supervising attending will not provide verbal cues regarding the identification of colon polyps as would typically occur during colonoscopies performed by a fellow, however, the fellow can request attending assistance at any time. Additionally, the attending will provide standard assistance with insertion and polypectomy techniques. While gastroenterology fellow participation in colonoscopy with attending supervision is standard at an academic medical center, pass #1 will be considered "research" for the purposes of this study as the attending will not be providing verbal cues regarding polyp detection as the purpose of this study is to quantify trainee miss rates independent of attending input.

Once the fellow completes pass #1, the attending physician will reinsert the colonoscope to the cecum and perform a second withdrawal (pass #2) with the assistance of the CADe system. A second proximal withdrawal time for pass #2 will be recorded until the splenic flexure is again reached and the attending feels that the colonic mucosa has been fully examined. Any polyps identified and resected by the attending physician during pass #2 will be considered "missed polyps."

The fellow and attending will then complete the exam from the splenic flexure to the rectum with the assistance of CADe, both providers identifying and resecting polyps as necessary, as is standard when a fellow performs colonoscopy with attending supervision.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

180

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Illinois
      • Chicago, Illinois, Verenigde Staten, 60611
        • Northwestern Memorial Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar en ouder (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Adult patients referred for screening or surveillance colonoscopy

Exclusion Criteria:

  • Patients referred for polypectomy or diagnostic colonoscopy
  • Patients with prior right colon surgery
  • Prolonged insertion time (>20 minutes)
  • Poor bowel preparation (Boston Bowel Preparation Score less than or equal to 6)

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Preventie
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: Colonoscopy with AI

Trainee using AI during colonoscopy inspection

Use of Computer-Aided Detection During Colonoscopy

Actieve vergelijker: Colonoscopy without AI

Trainee not using AI during colonoscopy inspection

Colonoscopy without Computer-Aided Detection (AI)

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Neoplastic polyp miss rate
Tijdsspanne: 1 week

Proportion of neoplastic (adenomas or serrated polyps) missed during trainee inspection

1 week

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Adenoma miss rate
Tijdsspanne: 1 week

Proportion of adenomas missed during trainee inspection

1 week
Serrated polyp miss rate
Tijdsspanne: 1 week

Proportion of serrated polyps missed during trainee inspection

1 week

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Rajesh Keswani, MD, Northwestern Medicine

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

10 september 2024

Primaire voltooiing (Werkelijk)

25 augustus 2026

Studie voltooiing (Werkelijk)

1 september 2026

Studieregistratiedata

Eerst ingediend

30 oktober 2024

Eerst ingediend dat voldeed aan de QC-criteria

4 november 2024

Eerst geplaatst (Werkelijk)

6 november 2024

Updates van studierecords

Laatste update geplaatst (Werkelijk)

28 september 2026

Laatste update ingediend die voldeed aan QC-criteria

23 september 2026

Laatst geverifieerd

1 september 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Beschrijving IPD-plan

No clear benefit in sharing this data

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Ja

product vervaardigd in en geëxporteerd uit de V.S.

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren