Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Impatto dell'intelligenza artificiale sui tassi di polipo mancante dei tirocinanti

23 settembre 2026 aggiornato da: Northwestern University

Impatto del rilevamento computerizzato sulla percentuale di polipi mancati in tirocinio utilizzando un progetto di colonscopia tandem

Based on prior studies, trainee and practicing gastroenterologists miss pre-cancerous polyps (adenomas and serrated polyps) during colonoscopy. The use of computer-aided detection (CADe) systems, a form of artificial intelligence (AI) has been shown to help identify colorectal lesions for practicing gastroenterologists. However, less is known how AI impacts polyp detection for trainees.

The investigators are conducting a tandem colonoscopy study wherein a portion of the colon is examined first by the trainee and then the attending physician. For each procedure, randomization will occur which will determine whether or not the trainee will utilize AI for their examination of the colon. At the end of the study, the investigators will determine whether AI helps trainees miss fewer polyps during colonoscopy. The investigators will also conduct interviews with trainees to understand how AI impacts colonoscopy training.

Panoramica dello studio

Descrizione dettagliata

Quality metrics in colonoscopy are useful in determining endoscopist performance. The adenoma detection rate (ADR) has historically been the primary colonoscopy quality indicator of interest, whereby those with a higher ADR have lower rates of interval colon cancers. Other important parameters include the adenoma miss rate (AMR) and the sessile serrated polyp miss rate (SMR).

The AMR among practicing gastroenterologists is estimated at around 25% based on tandem-colonoscopy studies, while the SMR may be even higher. Prior tandem colonoscopy studies have also shown that gastroenterology trainees have an AMR between 30-41% and an SMR between 56-86%. As missed polyps may grow into colorectal cancers over time, efforts must be dedicated to reducing AMR and SMR.

In 2021, the Food and Drug Administration (FDA) approved the first computer-aided detection (CADe) system, (GI-Genius; Medtronic, Minneapolis, MN) for identifying colorectal lesions in the United States. An initial tandem colonoscopy study among experienced endoscopists using this CADe system showed a reduction in AMR from 32.4% to 15.5%. However, it is unknown whether trainees would have a similar reduction in polyp miss rates.

CADe has been introduced into gastroenterology trainee education in a largely unstructured fashion and trainees' perception of CADe's impact on training is largely unknown. Presently, trainees and attendings complete colonoscopies with and without CADe. It is at the discretion of attendings whether CADe is used for a procedure regardless of whether or not a trainee is involved.

In this single center study, all Northwestern gastroenterology trainees will be invited to participate in the trial. First year gastroenterology trainees will initiate participation after 6 months of endoscopic training (approximately 100 colonoscopies completed). Trainees will be complete an hour-long meeting with the study team. The study protocol will be explained in detail and written informed consent will be obtained from the trainees.

The medical records of patients scheduled for ambulatory screening or surveillance colonoscopy during select endoscopy blocks will be screened in advance for inclusion in the study. Participants will be prospectively enrolled.

On the day of the patient's scheduled colonoscopy, a member of the study team will obtain written informed consent for both the colonoscopy and participation in the research study in a private bay in the pre-endoscopy area. The patient will then be transported to the procedure room and sedated. Sedation method (monitored anesthesia care or moderate sedation) will be determined prior to the scheduled appointment. If the patient is to receive moderate sedation, fentanyl and midazolam will be administered in incremental doses per the standard of care. Once the patient is sedated, the fellow and attending will perform the insertion as is standard for a colonoscopy in which a fellow is participating. Once the cecum is reached, the patient will then be randomized to whether the initial inspection of the right colon by the fellow is performed with or without the assistance of CADe in a 1:1 randomization. The fellow withdrawal (pass #1) will start. The fellow, with or without the use of CADe based on randomization, will identify polyps independently of the attending and remove them with attending assistance as appropriate until they feel that they have performed a complete examination of colonic mucosa from the cecum to the splenic flexure. During pass #1, the supervising attending will not provide verbal cues regarding the identification of colon polyps as would typically occur during colonoscopies performed by a fellow, however, the fellow can request attending assistance at any time. Additionally, the attending will provide standard assistance with insertion and polypectomy techniques. While gastroenterology fellow participation in colonoscopy with attending supervision is standard at an academic medical center, pass #1 will be considered "research" for the purposes of this study as the attending will not be providing verbal cues regarding polyp detection as the purpose of this study is to quantify trainee miss rates independent of attending input.

Once the fellow completes pass #1, the attending physician will reinsert the colonoscope to the cecum and perform a second withdrawal (pass #2) with the assistance of the CADe system. A second proximal withdrawal time for pass #2 will be recorded until the splenic flexure is again reached and the attending feels that the colonic mucosa has been fully examined. Any polyps identified and resected by the attending physician during pass #2 will be considered "missed polyps."

The fellow and attending will then complete the exam from the splenic flexure to the rectum with the assistance of CADe, both providers identifying and resecting polyps as necessary, as is standard when a fellow performs colonoscopy with attending supervision.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

180

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Illinois
      • Chicago, Illinois, Stati Uniti, 60611
        • Northwestern Memorial Hospital

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Adult patients referred for screening or surveillance colonoscopy

Exclusion Criteria:

  • Patients referred for polypectomy or diagnostic colonoscopy
  • Patients with prior right colon surgery
  • Prolonged insertion time (>20 minutes)
  • Poor bowel preparation (Boston Bowel Preparation Score less than or equal to 6)

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Prevenzione
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: Colonoscopy with AI

Trainee using AI during colonoscopy inspection

Use of Computer-Aided Detection During Colonoscopy

Comparatore attivo: Colonoscopy without AI

Trainee not using AI during colonoscopy inspection

Colonoscopy without Computer-Aided Detection (AI)

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Neoplastic polyp miss rate
Lasso di tempo: 1 week

Proportion of neoplastic (adenomas or serrated polyps) missed during trainee inspection

1 week

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Adenoma miss rate
Lasso di tempo: 1 week

Proportion of adenomas missed during trainee inspection

1 week
Serrated polyp miss rate
Lasso di tempo: 1 week

Proportion of serrated polyps missed during trainee inspection

1 week

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Rajesh Keswani, MD, Northwestern Medicine

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

10 settembre 2024

Completamento primario (Effettivo)

25 agosto 2026

Completamento dello studio (Effettivo)

1 settembre 2026

Date di iscrizione allo studio

Primo inviato

30 ottobre 2024

Primo inviato che soddisfa i criteri di controllo qualità

4 novembre 2024

Primo Inserito (Effettivo)

6 novembre 2024

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

28 settembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

23 settembre 2026

Ultimo verificato

1 settembre 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Descrizione del piano IPD

No clear benefit in sharing this data

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Sì

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi