Tijdelijke interferentiemethoden voor niet-invasieve diepe hersenstimulatie

In its totality, this grant aims to develop a line of research using temporal interference (TI) electrical neurostimulation technology to understand the causal role of deep brain structures in cognition. In the short term, the investigators aim to validate and characterize the effects of TI on brain activity as measured by fMRI and demonstrate its ability to focally stimulate deep brain regions without affecting overlying cortex. In the longer term, investigators aim to use these data to resolve longstanding debates about the function of deeper brain regions and lay the foundation for future clinical applications of TI for treating addiction, Obsessive-Compulsive Disorder (OCD), Parkinson's disease, and other disorders involving deep brain dysfunction. The grant supports 2 distinct aims, each of which will be evaluated through a series of independent studies.

Studie Overzicht

Gedetailleerde beschrijving

Through the grant's duration, the investigators hypothesize that temporal interference (TI) electrical neurostimulation will be well tolerated and effective at focally manipulating deep brain activity as measured by functional MRI (fMRI) BOLD signals. The investigators will investigate whether TI stimulation can increase BOLD activity in targeted deep brain regions including the nucleus accumbens (NAcc) and dorsal anterior cingulate cortex (dACC), and whether this stimulation can influence cognitive functions controlled by these regions. TI works by applying alternating currents of slightly different frequencies through multiple electrode pairs, creating an interference pattern that can stimulate deep brain regions without significantly affecting superficial cortical areas. This method is similar to traditional transcranial direct current stimulation (tDCS), however TI can stimulate deeper brain structures that tDCS cannot reach effectively. The study is broken up into two main aims with multiple sub-studies. In Aim 1, the investigators will characterize the effects of TI on fMRI BOLD signals, test different beat frequencies, and compare TI effects in the nucleus accumbens versus dorsal anterior cingulate cortex. In Aim 2, the investigators will apply TI to the dorsal anterior cingulate cortex to test causal theories about its role in cognitive control, conflict monitoring, risk avoidance, and foraging behavior using established cognitive tasks while subjects undergo fMRI scanning.

Study 1.1 (Aim 1, Study 1) will test the ability to focally activate the nucleus accumbens without activating the overlying cortex, and also its effects on functional connectivity. Healthy subjects (n=30) will present for a single study visit during which they will be placed in the fMRI scanner and administered a temporal interference protocol. Specifically, subjects will have two pairs of carbon fiber electrodes attached to the scalp with conductive gel. They will receive one 8-minute block of stimulation at 2mA per electrode pair. The stimulation sequence will be 2 minutes on, 2 minutes off, 2 minutes on, and 2 minutes off with 30 second ramp up and ramp down beginning at the start of each 2-minute period. The first block will apply active TI stimulation with 2000Hz in one channel and 2020Hz in the other channel. The second block will be a sham TI stimulation, identical to the first block but with the "on" condition immediately ramping down as soon as it reaches 2mA after ramp up. The third and fourth blocks will be identical to the first and second blocks, except that both electrode pairs will stimulate at 2000Hz, resulting in a "NO-TI active" and "NO-TI sham" conditions. The order of blocks, and whether the "on" or "off" condition occurs first within a block, will be counterbalanced across subjects.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

30

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Indiana
      • Bloomington, Indiana, Verenigde Staten, 47408
        • Indiana University Bloomington, Imaging Research Facility

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 50 jaar (Volwassen)

Accepteert gezonde vrijwilligers

Ja

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Between the ages of 18 and 50
  • Must have at least a 6th grade education
  • Ability to speak and read English for all phases

Exclusion Criteria:

  • Currently taking psychotropic medications for ADHD, other mental illness, or medications for cancer
  • History of epilepsy or seizure disorders
  • History of migraines or other neurological syndromes
  • History of AIDS (due to potential cognitive deficits)
  • History of head trauma or cognitive impairments
  • Personal experiences consistent with symptoms of psychosis (e.g., hallucinations, delusions of control or special powers)
  • History of skull defects (e.g., holes bored into the skull or known cranial fissures)
  • Metal implants in the head or under the scalp
  • Does not meet fMRI safety screening criteria (e.g., metal implants in the body, permanent jewelry, tattoos on the head or neck)
  • Uses an intrauterine device (IUD) for birth control and cannot provide documentation to verify MRI safety
  • Pregnancy (self-reported; no pregnancy test administered)
  • Weight over 440 lbs (scanner weight limit)
  • Presence of pacemakers

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Fundamentele wetenschap
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Crossover-opdracht
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: NAcc TI Active, then NAcc TI Sham, then NAcc No-TI Active, then NAcc No-TI Sham

Participants in this Arm receive temporal interference (TI) electrical stimulation with two pairs of carbon fiber electrodes in this order: NAcc TI Active, then NAcc TI Sham, then NAcc No-TI Active, then NAcc No-TI Sham.

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex.

For the NAcc TI Active condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex.

For the NAcc TI Sham condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the Active TI condition), the stimulation in the NAcc TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode.

For the NAcc No-TI Active condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode.

For the NAcc No-TI Sham condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the NAcc No-TI Active condition), the stimulation in the NAcc No-TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie
Actieve vergelijker: NAcc No-TI Active, then NAcc No-TI Sham, then NAcc TI Active, then NAcc TI Sham

Participants in this Arm receive temporal interference (TI) electrical stimulation with two pairs of carbon fiber electrodes in this order: NAcc No-TI Active, then NAcc No-TI Sham, then NAcc TI Active, then NAcc TI Sham.

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex.

For the NAcc TI Active condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex.

For the NAcc TI Sham condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the Active TI condition), the stimulation in the NAcc TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode.

For the NAcc No-TI Active condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode.

For the NAcc No-TI Sham condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the NAcc No-TI Active condition), the stimulation in the NAcc No-TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie
Actieve vergelijker: NAcc TI Sham, then NAcc TI Active, then NAcc No-TI Sham, then NAcc No-TI Active

Participants in this Arm receive temporal interference (TI) electrical stimulation with two pairs of carbon fiber electrodes in this order: NAcc TI Sham, then NAcc TI Active, then NAcc No-TI Sham, then NAcc No-TI Active.

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex.

For the NAcc TI Active condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex.

For the NAcc TI Sham condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the Active TI condition), the stimulation in the NAcc TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode.

For the NAcc No-TI Active condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode.

For the NAcc No-TI Sham condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the NAcc No-TI Active condition), the stimulation in the NAcc No-TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie
Actieve vergelijker: NAcc No-TI Sham, then NAcc No-TI Active, then NAcc TI Sham, then NAcc TI Active

Participants in this Arm receive temporal interference (TI) electrical stimulation with two pairs of carbon fiber electrodes in this order: NAcc No-TI Sham, then NAcc No-TI Active, then NAcc TI Sham, then NAcc TI Active.

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex.

For the NAcc TI Active condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex.

For the NAcc TI Sham condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the Active TI condition), the stimulation in the NAcc TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode.

For the NAcc No-TI Active condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode.

For the NAcc No-TI Sham condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the NAcc No-TI Active condition), the stimulation in the NAcc No-TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.

Andere namen:
  • TI elektrische neurostimulatie
  • TI Neurostimulatie

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Change From Baseline (no Stimulation) in Brain Activity in the Nucleus Accumbens During Active Versus Sham Stimulation
Tijdsspanne: During fMRI scanning for each study session (active and sham stimulation), approximately 60 minutes

Brain activity in the nucleus accumbens was measured using functional magnetic resonance imaging (fMRI) during active temporal interference (TI) brain stimulation compared to sham stimulation. Activity change from baseline (no stimulation) was quantified using region-of-interest (ROI) beta estimates extracted from the nucleus accumbens. The beta estimates were derived from blood-oxygen-level-dependent (BOLD) signal changes measured during fMRI and reflect the magnitude of task-related neural activation within the ROI. Higher beta values indicate greater task-related activation. Whole-brain voxelwise analyses did not identify statistically significant activation clusters after correction for multiple comparisons; therefore, descriptive ROI-level beta estimates are reported.

During fMRI scanning for each study session (active and sham stimulation), approximately 60 minutes

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Change From Baseline (no Stimulation) in Brain Activity in the Nucleus Accumbens During No-TI Active Versus No-TI Sham High-frequency Stimulation
Tijdsspanne: During fMRI scanning for each study session (active and sham no-TI stimulation conditions), approximately 60 minutes

Brain activity in the nucleus accumbens was measured using functional magnetic resonance imaging (fMRI) during no-temporal interference (no-TI) control stimulation, in which both electrode pairs delivered the same frequency. Change in activity from baseline (no stimulation) was quantified using region-of-interest (ROI) beta estimates extracted from the nucleus accumbens during NO-TI active versus NO-TI sham high-frequency stimulation to determine whether high-frequency stimulation alone altered brain activity. The beta estimates were derived from blood-oxygen-level-dependent (BOLD) signal changes measured during fMRI and reflect the magnitude of task-related neural activation within the ROI. Higher beta values indicate greater task-related activation. Whole-brain voxelwise analyses did not identify statistically significant activation differences after correction for multiple comparisons; therefore, descriptive ROI-level beta estimates are reported.

During fMRI scanning for each study session (active and sham no-TI stimulation conditions), approximately 60 minutes
Change From Baseline (no Stimulation) in Brain Activity in the Nucleus Accumbens During Active TI Stimulation Versus Active No-TI Stimulation
Tijdsspanne: During fMRI scanning for each study session (active TI and active no-TI stimulation conditions), approximately 60 minutes

Brain activity in the nucleus accumbens was compared between active temporal interference (TI) stimulation and active high-frequency no-temporal interference (no-TI) stimulation using functional magnetic resonance imaging (fMRI). Change in activity from baseline (no stimulation) was quantified using region-of-interest (ROI) beta estimates extracted from the nucleus accumbens to determine whether TI stimulation produced greater task-related activation than high-frequency stimulation alone. The beta estimates were derived from blood-oxygen-level-dependent (BOLD) signal changes measured during fMRI and reflect the magnitude of task-related neural activation within the ROI. Higher beta values indicate greater task-related activation. Whole-brain voxelwise analyses did not identify statistically significant activation differences after correction for multiple comparisons; therefore, descriptive ROI-level beta estimates are reported.

During fMRI scanning for each study session (active TI and active no-TI stimulation conditions), approximately 60 minutes
Change in Brain Connectivity Between the Nucleus Accumbens and Other Brain Regions During Stimulation
Tijdsspanne: During fMRI scanning for each study session (active and sham stimulation conditions), approximately 60 minutes

Functional connectivity between the nucleus accumbens and other brain regions was planned to be evaluated using fMRI-based psycho-physiological interaction (PPI) analyses during active versus sham temporal interference (TI) stimulation. Higher correlation values indicate stronger functional connectivity between brain regions. The primary test statistic was the whole-brain interaction term between seed-region BOLD activity and stimulation condition (active vs. sham TI). This analysis was not performed because no statistically significant activation clusters were identified from which to define a seed region.

During fMRI scanning for each study session (active and sham stimulation conditions), approximately 60 minutes

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Joshua W Brown, PhD, Indiana University, Bloomington

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

12 november 2025

Primaire voltooiing (Werkelijk)

2 februari 2026

Studie voltooiing (Werkelijk)

2 februari 2026

Studieregistratiedata

Eerst ingediend

29 september 2025

Eerst ingediend dat voldeed aan de QC-criteria

7 oktober 2025

Eerst geplaatst (Werkelijk)

10 oktober 2025

Updates van studierecords

Laatste update geplaatst (Werkelijk)

4 november 2026

Laatste update ingediend die voldeed aan QC-criteria

13 oktober 2026

Laatst geverifieerd

1 juni 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • 26941, Study 1.1
  • 1R21MH140210-01 (Subsidie/contract van de Amerikaanse NIH)

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Ja

product vervaardigd in en geëxporteerd uit de V.S.

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .