- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT02866617
Randomized Controlled Clinical Trial Of Oral Health-Related Quality Of Life In Patients Wearing Vacuum Formed Thermoplastic Retainers Constructed On Conventional Stone Models And On 3D Reconstructed Orthodontic Study Model
In dentistry, 3D printing technology is gaining interest. One of the potential application is to construct appliances on 3D reconstructed study models.
The purpose of this study is to compare vacuum formed thermoplastic orthodontic retainers (VFR) constructed on conventional orthodontic study models and reconstructed 3D study models by assessing the oral health-related quality of life (OHRQoL) instrument, Little's Irregularity Index (LII) and compliance.
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Detaljert beskrivelse
Aim:
To compare the impact of 2 types of vacuum formed thermoplastic retainers on patients.
Objectives:
- To compare oral health-related quality of life in patients wearing vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
- To compare compliance between vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
- To compare stability in patients wearing vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
Research Methadology
Ethical Consideration:
Application for ethical approval from Medical Ethics Committee, Faculty of Dentistry, University of Malaya.
Study population
This randomized controlled clinical trial will include existing patients who visited the Faculty of Dentistry, University of Malaya, for fixed orthodontic treatment and are due to have their fixed appliances removed.
5.2 Sample Size Estimation
Sample size estimation is based on previous study done by Jäderberg et al (2012) and calculated using PS Software (Power and Sample Size Calculation).
A sample size calculation was performed based on an alpha significance level of 0.05 and a beta of 0.1 to achieve 90 per cent power to detect a clinically meaningful difference of 1.0 mm [standard deviation (SD) 1.0] between the groups. The sample size calculation revealed that 22 pairs of sample were sufficient. This number of sample size will also achieve a moderate Pearson Product Moment correlation between the two groups. However, to compensate for possible dropouts, 30 pairs were enrolled in this clinical trials.
5.4 Materials and methods
- Enrollment & Randomization Potential subjects will be recruited from the patients receiving orthodontic treatment at the Faculty of Dentistry, University of Malaya. Patients were screened based on when they were scheduled for debonding and the inclusion and exclusion criteria listed above. An online random number generator was used to create a randomization list of study numbers matched to either Group A or Group B. The day of debonding potential subjects were given consent and officially enrolled in the study.
Study Groups As the flow chart below illustrates, two study groups existed for this randomized cross-over observational study. Each study group received 3 sets of vacuum formed thermoplastic retainers. Group A will wear vacuum formed thermoplastic retainers constructed by laboratory technician according to their standard protocol for 1 week from the day of debond, then vacuum formed thermoplastic retainers constructed on stone study model by one dentist after 1 week of debond for 3 months and later vacuum formed thermoplastic retainers constructed on 3D reconstructed study model for another 3 months.
Group B will wear vacuum formed thermoplastic retainers constructed by laboratory technician according to their standard protocol for 1 week from the day of debond, then vacuum formed thermoplastic retainers constructed on 3D reconstructed study model by one dentist after 1 week of debond for 3 months and later vacuum formed thermoplastic retainers constructed on stone study model for another 3 months.
Study Visit #1- Debonding Appointment
All subjects were debonded by resident doctor, all residual composite removed, and teeth appropriately polished. Final photos were taken per University Clinic protocol. After debond, maxillary and mandibular alginate impressions (Hydrogum 5, Zhermack, Italy) will be obtained from each sample; two for working model and one for study model). One set of impression will be sent to University's Orthodontic Laboratory for construction of vacuum formed thermoplastic retainer by the laboratory technician for 1st appliance (to be issued on the same day of debond). The vacuum formed thermoplastic retainerss were made in the lab using thermoplastic material and clinic's Biostar machine available at the lab using the standard instructions provided by the manufacturer. vacuum formed thermoplastic retainerss were cooled and trimmed accordingly. Clinically vacuum formed thermoplastic retainerss were evaluated by resident doctor intra orally and were adjusted for patient comfort. All subjects were instructed to wear their retainers full time, only remove to eat, brush, and clean. For the remaining two sets of impression, the impression is poured in dental stone within 24hours.
- Acquisition of stone study model. Impressions obtained will be disinfect before casting. The white stone (Elite Ortho, Zhermack, Italy) is mixed and tapped into the impression a little at a time to ensure no air is trapped within the stone mix and some stone is used to form the base. Once the stone has set sufficiently, the impression is inverted on the base. When casting the lower impression, stone in the lingual section is removed before setting fully to ensure that the impression can easily be removed from the model.
Once the base has fully set the impression will be carefully removed from the stone and gradually lifted from the model using a plaster knife. The resulting stone model is then trimmed using a model trimmer. The base of the model parallel to the occlusal plane is trimmed to ensure even adaption of the thermoforming material. The back edge of the model should be trimmed so that it is at 90° to the sagittal plane. The labial and buccal sides of the model should be trimmed round so that the final model is a 'D' shape.
5 : Acquisition of digital model. Conventional study model will be scanned using structured light scanner (Maestro 3D, Age Solutions, Inc, Italy) via EasyDentalScan software (Age Solutions, Inc) to produce 3D digital model. The scanned data for both upper and lower conventional study models will be saved and exported as binary stereolithographic (.stl) files.
6 : Acquisition of reconstructed model. A Fused Deposition Modelling (FDM) machine (UP! 2 Plus 3D Printer) containing acrylonitrile butadiene styrene (ABS) plastic will be used to construct replica (RP) model from digital file according to manufacturing instructions. This process will be done by CBMTI SDN BHD ( a subsidiary of UM CAPITAL BERHAD), Institute of Postgraduate Studies, University of Malaya.
The prototyping process begins with unwinding the feedstock filament from a reel and feeding it through the liquefier located inside the system working envelop, as shown in figure below, where it gets gradually heated by temperature gradient provided by a number of coils wrapped helically about the axis of the liquefier .
The heated liquefier melts the plastic filament and deposits the melt through a nozzle attached at the exit controlling the diameter of final extrudate. Two step motors at the entrance of liquefier make sure a continuous supply of material during the model build-up. The nozzle and liquefier assembly is mounted onto a mechanical stage numerically controlled in X-Y plane. Upon receipt of precise tool paths prepared by the Insight software, the nozzle moves over the foam substrate depositing a thin bead of thermoplastic model material along with any necessary support structure. Deposition of fine extruded filaments onto the substrate produces a layer corresponding to a slice of the CAD model of the object. Once a layer is built the substrate moves down in z direction in order to prepare the stage for the deposition of next layer. The deposited filaments cool down immediately below the glass transition temperature of the polymer and get hardened. The entire build system is contained within a temperature- controlled environment with temperatures just below the glass-transition temperature of the polymer to provide an efficient intra-layer bonding.
7 : Acquisition of vacuum formed thermoplastic retainer
Each VFR was constructed from an Erkodur blank (Erkodent, Erich Kopp, GmbH, Pfalzgrafenweiler, Germany) 1.5 mm in thickness using the standard instructions provided by the laboratory's Biostar machine.
Retainer Designs:
vacuum formed thermoplastic retainerss Designs- Extraction and Non-extraction Cases
- Upper- Trimmed for 1-2mm of facial gingival coverage, palatal coverage, and 2nd Molar occlusal coverage
Lower- Trimmed for 1-2mm of facial and lingual gingival coverage, 2nd Molar occlusal coverage.
8 : T2 and T3 visit: Issuing the vacuum formed thermoplastic retainer. The 2nd retainers will be fitted within 1 week after debond (T1) and the 3rd retainers is fitted 3 months (T2) after debond. The duration of retainer wear was standardized based on the standard protocol for retainer wear in the practice. The patients were instructed to wear the vacuum formed thermoplastic retainers 24 hours a day for the first week and remove them only for eating and brushing their teeth. After the first week, wear time was reduced to 10 hours a day (Thickett and Power, 2009). All patients will be provided with standardized oral and written instructions on how to use the retainers by one dentist.
The subjects were reviewed by a member of the research team at 2 intervals, 3 months (T2) and 6 months (T3) after debond. At the 3 month (T2) review appointment, the subjects will be given the Questionnaire Q2 to be filled up. Later, the 3rd retainer will be given to the subjects and again to be reviewed after 3 months (T3) of 3rd retainer issued ( 6 months after debond) and questionnaire Q3 will be administered.
Studietype
Registrering (Faktiske)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
-
Kuala Lumpur, Malaysia, 50603
- Faculty of Dentistry, University of Malaya
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Barn
- Voksen
- Eldre voksen
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion criteria
- fixed appliance treatment following both arches;
- indicated for vacuum formed thermoplastic retainers as retention phase in treatment plan;
Exclusion criteria:
- single-arch or sectional fixed appliance treatment,
- hypodontia requiring tooth replacement on the retainer as a temporary measure,
- undergone rapid maxillary expansion,
- indicated for double retention regime (bonded retainers),
- early debonding patients.
- patients intending to relocate within the study period
- patient with learning difficulties and can't read written instructions/questionnaire in English or Malay
- patient with cleft lip or palate
- has undergone surgical treatment
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Annen
- Tildeling: Randomisert
- Intervensjonsmodell: Crossover-oppdrag
- Masking: Dobbelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
---|---|
Eksperimentell: Conventional
T1-T2 : VFR constructed on conventional study model T2-T3 : VFR constructed on 3D reconstructed study model
|
|
Eksperimentell: 3D
T1-T2 : VFR constructed on 3D reconstructed study model T2-T3 :VFR constructed on conventional study model
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tidsramme |
---|---|
Oral Health-Related Quality Of Life
Tidsramme: 6 month
|
6 month
|
Sekundære resultatmål
Resultatmål |
Tidsramme |
---|---|
Little's Irregularity Index
Tidsramme: 6 month
|
6 month
|
Andre resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
---|---|---|
Patient's compliance on wearing orthodontic retainers
Tidsramme: 6 month
|
A survey of patient's compliance wearing the orthodontic retainers in 6 months
|
6 month
|
Samarbeidspartnere og etterforskere
Sponsor
Etterforskere
- Hovedetterforsker: Wan Nurazreena Wan Hassan, BDS, University of Malaya
Publikasjoner og nyttige lenker
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Anslag)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Andre studie-ID-numre
- PPPC/C1-2015/DGD/12
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .
Kliniske studier på Livskvalitet
-
Marlene FischerFullførtPostoperativ Quality of Recovery i Postanesthesia Care UnitTyskland
-
Anqing Municipal HospitalFullførtDexmedetomidin | Lidokain | Quality of Recovery (QoR-40), Preoperativ og PostoperativKina
-
University Hospital, GrenobleUkjentHealth Care Quality Management (ingen betingelse).Frankrike
-
Prisma Health-UpstateNational Institute on Drug Abuse (NIDA); Clemson UniversityRekrutteringVelferdstandard | Standard of Care + CBT4CBT | Standard of Care + CBT4CBT + RCForente stater
-
Sorbonne UniversityAalborg UniversityRekrutteringPoint of Care UltralydFrankrike
-
Imperial College LondonFullført
-
Asociacion Española Primera en SaludIntensive Care Unit Pasteur HospitalFullførtPoint of Care UltralydUruguay
-
Aga Khan UniversityThe Hospital for Sick Children; Grand Challenges CanadaUkjentPoint of Care UltralydPakistan
-
Research Unit Of General Practice, CopenhagenUniversity of Copenhagen; Region Capital Denmark; The Copenhagen General... og andre samarbeidspartnereFullført
-
Nimble Science Ltd.University of Calgary; Lallemand Health SolutionsFullført