- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT04270045
Tvunget oscillometri hos spedbarn med bronkopulmonal dysplasi
The purpose of this study is to use forced oscillometry technique (FOT) to measure pulmonary mechanics and function in in term infants and premature infants with bronchopulmonary dysplasia (BPD)
Studieoversikt
Status
Intervensjon / Behandling
Detaljert beskrivelse
Pulmonary function testing has been the standard of care to diagnose and evaluate response to therapy in various respiratory diseases in adults and children. There are several equipment and techniques that are FDA approved for these purposes. However, there are currently no lung function tests that are practically feasible, clinically meaningful and widely used in infants.
The forced oscillation technique (FOT) is a non-invasive method that had been used to measure respiratory mechanics. FOT employs small amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory maneuvers. To date, the use of this technique is FDA approved in adults and children but remains largely experimental in infants and newborns. THORASYS has recently developed a new respiratory function test device aimed specifically at newborn and infants (0 - 2 years age group) called tremoflo N-100 ("Neo"). This new device measures lung function in only a few minutes while the newborn or infant is sleeping normally. It uses an adapted version of the Airwave Oscillometry (AOS) to calculate the impedance of the lungs and quantify airway obstruction.
Diuretics and bronchodilators are two on the most commonly used medications to ameliorate the symptoms of BPD. The benefits of these therapies have not been shown to prevent the development of BPD in a randomized control trial (RCT). More recently, there have been some evidence from pharmacogenetic studies that the variability in bronchodilator responsiveness in patients with asthma, (and possibly BPD) may lie on the gene encoding the B2-adrenergic receptor (ADRB2) as well as within the associated G-protein receptor pathway, the nitric oxide biosynthetic pathway and other novel loci identified in recent genome-wide studies. This part of the study will be hypothesis generating to try to understand the variability in bronchodilator response in infants with BPD. Normative data will be established in term neonates.
Studietype
Registrering (Faktiske)
Kontakter og plasseringer
Studiesteder
-
-
Missouri
-
Kansas City, Missouri, Forente stater, 64108
- Children's Mercy Hospital
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Barn
- Voksen
- Eldre voksen
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Prøvetakingsmetode
Studiepopulasjon
Premature infants with bronchopulmonary Dysplasia who are in room air or Premature infants with BPD who are receiving low flow O2 support and able to maintain normal spO2 in Room air for brief period (up to 3 minutes) Term infants without pulmonary disease. Former preterm infants (<32 weeks) with BPD seen prior to 2 years of age in the outpatient setting.
Beskrivelse
Inclusion Criteria:
Preterm Cohort:
- Premature infants with BPD who are in room air based on the (per NICHD definition)
- Premature infants with BPD who are receiving low flow O2 support and able to maintain normal spO2 in Room air for brief period ( up to 3 minutes) Term Cohort without pulmonary disease
- Infants >36 weeks gestational age without pulmonary disease
- Infants < 4 weeks of age
Outpatient Cohort:
- Former preterm infants < 32 weeks at birth
- Those with BPD based on NIH 2001 definition
- Seen prior to 2 years of age
Exclusion Criteria:
- Infants with BPD requiring invasive or non-invasive positive pressure ventilation
- Infants with BPD who have associated genetic diagnosis or major congenital anomalies.
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Observasjonsmodeller: COHORT
- Tidsperspektiver: PROSPECTIVE
Kohorter og intervensjoner
Gruppe / Kohort |
Intervensjon / Behandling |
|---|---|
|
Single
Non-invasive forced airway oscillometry. Normative data will be established form term neonates without pulmonary disease |
This non-invasive device will measure pulmonary mechanics in spontaneously breathing premature infants and term infants without pulmonary disease. Infant will be in supine position and breathing regularly. A cushioned mask will be placed on the infant's face, covering the nose and mouth. Measurements typically take less than 20 seconds and no more than 3 repetitions will be done at each time point. |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Forced oscillation technique measurements
Tidsramme: FOT measurement prior to bronchodilator therapy
|
Baseline FOT measurements in premature infants with BPD and term infants without pulmonary disease. |
FOT measurement prior to bronchodilator therapy
|
|
Post-bronchodilator forced oscillation technique measurements (in subjects already receiving this therapy)
Tidsramme: FOT measurement 30 to 60minutes following bronchodilator therapy
|
FOT measurements in premature infants with BPD following bronchodilator therapy. |
FOT measurement 30 to 60minutes following bronchodilator therapy
|
Samarbeidspartnere og etterforskere
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- STUDY00000912
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .