Geforceerde oscillometrie bij zuigelingen met bronchopulmonale dysplasie
The purpose of this study is to use forced oscillometry technique (FOT) to measure pulmonary mechanics and function in in term infants and premature infants with bronchopulmonary dysplasia (BPD)
Studie Overzicht
Toestand
Interventie / Behandeling
Gedetailleerde beschrijving
Pulmonary function testing has been the standard of care to diagnose and evaluate response to therapy in various respiratory diseases in adults and children. There are several equipment and techniques that are FDA approved for these purposes. However, there are currently no lung function tests that are practically feasible, clinically meaningful and widely used in infants.
The forced oscillation technique (FOT) is a non-invasive method that had been used to measure respiratory mechanics. FOT employs small amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory maneuvers. To date, the use of this technique is FDA approved in adults and children but remains largely experimental in infants and newborns. THORASYS has recently developed a new respiratory function test device aimed specifically at newborn and infants (0 - 2 years age group) called tremoflo N-100 ("Neo"). This new device measures lung function in only a few minutes while the newborn or infant is sleeping normally. It uses an adapted version of the Airwave Oscillometry (AOS) to calculate the impedance of the lungs and quantify airway obstruction.
Diuretics and bronchodilators are two on the most commonly used medications to ameliorate the symptoms of BPD. The benefits of these therapies have not been shown to prevent the development of BPD in a randomized control trial (RCT). More recently, there have been some evidence from pharmacogenetic studies that the variability in bronchodilator responsiveness in patients with asthma, (and possibly BPD) may lie on the gene encoding the B2-adrenergic receptor (ADRB2) as well as within the associated G-protein receptor pathway, the nitric oxide biosynthetic pathway and other novel loci identified in recent genome-wide studies. This part of the study will be hypothesis generating to try to understand the variability in bronchodilator response in infants with BPD. Normative data will be established in term neonates.
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
Missouri
-
Kansas City, Missouri, Verenigde Staten, 64108
- Children's Mercy Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Kind
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Premature infants with bronchopulmonary Dysplasia who are in room air or Premature infants with BPD who are receiving low flow O2 support and able to maintain normal spO2 in Room air for brief period (up to 3 minutes) Term infants without pulmonary disease. Former preterm infants (<32 weeks) with BPD seen prior to 2 years of age in the outpatient setting.
Beschrijving
Inclusion Criteria:
Preterm Cohort:
- Premature infants with BPD who are in room air based on the (per NICHD definition)
- Premature infants with BPD who are receiving low flow O2 support and able to maintain normal spO2 in Room air for brief period ( up to 3 minutes) Term Cohort without pulmonary disease
- Infants >36 weeks gestational age without pulmonary disease
- Infants < 4 weeks of age
Outpatient Cohort:
- Former preterm infants < 32 weeks at birth
- Those with BPD based on NIH 2001 definition
- Seen prior to 2 years of age
Exclusion Criteria:
- Infants with BPD requiring invasive or non-invasive positive pressure ventilation
- Infants with BPD who have associated genetic diagnosis or major congenital anomalies.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Observatiemodellen: COHORT
- Tijdsperspectieven: PROSPECTIVE
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Single
Non-invasive forced airway oscillometry. Normative data will be established form term neonates without pulmonary disease |
This non-invasive device will measure pulmonary mechanics in spontaneously breathing premature infants and term infants without pulmonary disease. Infant will be in supine position and breathing regularly. A cushioned mask will be placed on the infant's face, covering the nose and mouth. Measurements typically take less than 20 seconds and no more than 3 repetitions will be done at each time point. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Forced oscillation technique measurements
Tijdsspanne: FOT measurement prior to bronchodilator therapy
|
Baseline FOT measurements in premature infants with BPD and term infants without pulmonary disease. |
FOT measurement prior to bronchodilator therapy
|
|
Post-bronchodilator forced oscillation technique measurements (in subjects already receiving this therapy)
Tijdsspanne: FOT measurement 30 to 60minutes following bronchodilator therapy
|
FOT measurements in premature infants with BPD following bronchodilator therapy. |
FOT measurement 30 to 60minutes following bronchodilator therapy
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- STUDY00000912
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .